Danfoss EKF Series Manuals

1 pdf manual(s) Danfoss EKF Series for free download (Document Types: Installation manual)

Danfoss EKF Series Installation manual Thumbnail

Danfoss EKF Series Installation manual [PDF] (7 pages)

  • Identifier: id-2227199
  • Brand: Danfoss
  • Device: Danfoss EKF Series Control Unit
  • Type: Installation manual, PDF
  • Key Aspects: Technical Data and Parameters, Efficiency and Calibration Tips, Troubleshooting Information
  • UPD Date: 24.04.2026
  • Source File: 2060433.pdf
  • Pages: 7
  • Description: User support manual for the Danfoss EKF Series.
Pages Preview:
  • Danfoss EKF Series Installation manual preview - page 2
  • Danfoss EKF Series Installation manual preview - page 3
  • Danfoss EKF Series Installation manual preview - page 4
  • Danfoss EKF Series Installation manual preview - page 5
  • Danfoss EKF Series Installation manual preview - page 6
  • Danfoss EKF Series Installation manual preview - page 7
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Installation guide Stepper Valve Driver Type EKF 1A, EKF 2A 080R0435 © Danfoss | Climate Solutions | 2021.07 AN375548103097en-000202 | 1 Імпортер:ТОВ з іі "Данфосс ТОВ" 04080, Київ 80, п/с 168, Україна Info for UK customers only: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB 080R0435 Introduction Stepper Valve Driver EKF series is for use where stepper motor valves must be accurately controlled, typically in commercial air conditioning, heat pumps, commercial refrigeration and food retailing applications. Supply voltage EKF 1A: 24 V AC / DC 50 / 60 Hz EKF 2A: 24 V AC / DC, 50 / 60 Hz Power consumption Idle operating: < 1 W (without valve) Power consumption for using 1 valve. CCMT 16 – CCMT 42: 25 VA / 15 W ETS 5M, ETS 6: 20 VA / 10 W ETS 12C – ETS 100C, KVS C: 30 VA /15 W ETS 12.5 – 400: 10 VA / 5 W ETS 500P, 800P: 28 VA / 20 W CCMT 2- CCMT 8: 10 VA / 5 W CTR 20: 14 VA / 10 W CCMT L: 20 VA / 10 W When using two valves sum the power consumption of each valve. Analog inputs EKF 1A: 1 input AI1 0-5 V, 0-10 V, 4-20 mA, 0-20 mA EKF 2A: 2 inputs AI1 and AI2 0-5 V, 0-10 V, 4-20 mA, 0-20 mA Max. 15 V Analog input voltage. Do not connect voltage sources to unpowered units without limiting the current to analog inputs (overall 40 mA per input). Input Impedance: >50 kΩ (Voltage Input) 120 Ω ± 2% (Current Input) Digital outputs 1 output for EKF1A / EKF 2A: D01 (open collector), sink current max 10 mA Valve support EKF 1A: 1 stepper motor valve output, EKF 2A: 2 stepper motor valve output STEPPER 1: A1, A2, B1, B2 STEPPER 2: A1, A2, B1, B2 Bipolar and unipolar stepper motor output: - Danfoss ETS / KVS / ETS C / KVS C / CCMT 2 – CCMT 42 / CTR / CCMT L Valves - ETS 6 / ETS 5M Valves Open circuit HW diagnostics is present. Battery backup 1 input for EKF 1A / EKF2A: Vbat BAT, GND: Nominal 18 – 24 V DC, Min 16 V DC - Max 28 V DC (EKE 2U recommended) Max. battery current: 2 A at 18 V (valve depended) Battery alarm/warning will be activated below 16 V DC. Enviroment Storage -30 – 80 °C / -22 – 176 °F Operating -20 – 60 °C / -4 – 140 °F Humidity < 90% RH, non-condensing DIN Mounting 4 DIN Technical Specificatons

Similar Manuals in the Control Unit Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
American Standard 7017 Series

American Standard Control Unit Installation instructions manual (File: PDF, 21-06-2026)

6 319 64 21-06-2026 view all manuals
Baumuller b maXX BM4 Series

Baumuller Control Unit Instruction handbook manual (File: PDF, 31-05-2026)

84 140 21 31-05-2026 view all manuals
Huawei UPS5000-S200K-SM

#7X864K: UPS5000-S200K-SM UPS Manual 

16 201 33 27-05-2026 view all manuals
Danfoss 087H3817

087H3817 Installation manual - WI6TKY

16 576 116 24-06-2026 view all manuals
Emerson Q Series

PDF User Manual (@8MP1P3), Emerson Q Series Control Unit (28-03-2026)

13 411 91 28-03-2026 view all manuals
HEIDENHAIN TNC 370

TNC 370 Operation & user’s manual - F593DH

333 1091 241 30-04-2026 view all manuals