Danfoss EKF Series Manuals
1 pdf manual(s) Danfoss EKF Series for free download (Document Types: Installation manual)
Danfoss EKF Series Installation manual [PDF] (7 pages)
- Identifier: id-2227199
- Brand: Danfoss
- Device: Danfoss EKF Series Control Unit
- Type: Installation manual, PDF
- Key Aspects: Technical Data and Parameters, Efficiency and Calibration Tips, Troubleshooting Information
- UPD Date: 24.04.2026
- Source File: 2060433.pdf
- Pages: 7
- Description: User support manual for the Danfoss EKF Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Installation guide Stepper Valve Driver Type EKF 1A, EKF 2A 080R0435 © Danfoss | Climate Solutions | 2021.07 AN375548103097en-000202 | 1 Імпортер:ТОВ з іі "Данфосс ТОВ" 04080, Київ 80, п/с 168, Україна Info for UK customers only: Danfoss Ltd., 22 Wycombe End, HP9 1NB, GB 080R0435 Introduction Stepper Valve Driver EKF series is for use where stepper motor valves must be accurately controlled, typically in commercial air conditioning, heat pumps, commercial refrigeration and food retailing applications. Supply voltage EKF 1A: 24 V AC / DC 50 / 60 Hz EKF 2A: 24 V AC / DC, 50 / 60 Hz Power consumption Idle operating: < 1 W (without valve) Power consumption for using 1 valve. CCMT 16 – CCMT 42: 25 VA / 15 W ETS 5M, ETS 6: 20 VA / 10 W ETS 12C – ETS 100C, KVS C: 30 VA /15 W ETS 12.5 – 400: 10 VA / 5 W ETS 500P, 800P: 28 VA / 20 W CCMT 2- CCMT 8: 10 VA / 5 W CTR 20: 14 VA / 10 W CCMT L: 20 VA / 10 W When using two valves sum the power consumption of each valve. Analog inputs EKF 1A: 1 input AI1 0-5 V, 0-10 V, 4-20 mA, 0-20 mA EKF 2A: 2 inputs AI1 and AI2 0-5 V, 0-10 V, 4-20 mA, 0-20 mA Max. 15 V Analog input voltage. Do not connect voltage sources to unpowered units without limiting the current to analog inputs (overall 40 mA per input). Input Impedance: >50 kΩ (Voltage Input) 120 Ω ± 2% (Current Input) Digital outputs 1 output for EKF1A / EKF 2A: D01 (open collector), sink current max 10 mA Valve support EKF 1A: 1 stepper motor valve output, EKF 2A: 2 stepper motor valve output STEPPER 1: A1, A2, B1, B2 STEPPER 2: A1, A2, B1, B2 Bipolar and unipolar stepper motor output: - Danfoss ETS / KVS / ETS C / KVS C / CCMT 2 – CCMT 42 / CTR / CCMT L Valves - ETS 6 / ETS 5M Valves Open circuit HW diagnostics is present. Battery backup 1 input for EKF 1A / EKF2A: Vbat BAT, GND: Nominal 18 – 24 V DC, Min 16 V DC - Max 28 V DC (EKE 2U recommended) Max. battery current: 2 A at 18 V (valve depended) Battery alarm/warning will be activated below 16 V DC. Enviroment Storage -30 – 80 °C / -22 – 176 °F Operating -20 – 60 °C / -4 – 140 °F Humidity < 90% RH, non-condensing DIN Mounting 4 DIN Technical Specificatons
Similar Manuals in the Control Unit Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
American Standard 7017 Series |
American Standard Control Unit Installation instructions manual (File: PDF, 21-06-2026) |
6 | 319 | 64 | 21-06-2026 | view all manuals | |
Baumuller b maXX BM4 Series |
Baumuller Control Unit Instruction handbook manual (File: PDF, 31-05-2026) |
84 | 140 | 21 | 31-05-2026 | view all manuals | |
Huawei UPS5000-S200K-SM |
#7X864K: UPS5000-S200K-SM UPS Manual |
16 | 201 | 33 | 27-05-2026 | view all manuals | |
Danfoss 087H3817 |
087H3817 Installation manual - WI6TKY |
16 | 576 | 116 | 24-06-2026 | view all manuals | |
Emerson Q Series |
PDF User Manual (@8MP1P3), Emerson Q Series Control Unit (28-03-2026) |
13 | 411 | 91 | 28-03-2026 | view all manuals | |
HEIDENHAIN TNC 370 |
TNC 370 Operation & user’s manual - F593DH |
333 | 1091 | 241 | 30-04-2026 | view all manuals |