Danfoss Optyma Blue OP-LGHE068NTA07D Manuals

1 pdf manual(s) Danfoss Optyma Blue OP-LGHE068NTA07D for free download (Document Types: Instructions manual)

Available Documents for Optyma Blue OP-LGHE068NTA07D:

Danfoss Optyma Blue OP-LGHE068NTA07D Instructions manual Main Page Preview

Instructions manual [PDF] (8 pages)

  • Brand: Danfoss
  • Model: Optyma Blue OP-LGHE068NTA07D
  • Format: PDF
  • Key Aspects: Best Practices for Everyday Use, Component Longevity Optimization, Standard Operating Procedures
  • Updated: 21.05.2026
  • Source File: 1768042.pdf
  • Pages: 8
  • Description: Technical setup manual for the Danfoss Optyma Blue OP-LGHE068NTA07D.

Document Preview & Text Transcription

Instructions Optyma™ Blue Condensing units © Danfoss | DCS (CC) | 2019.01 AN293820378892en-000101 | 1 Code Model Name Refrigerant 114X8056 OP-LGHE068NTA07D R404A/R507 114X8057 OP-LCHE096NTA07D 114X8058 OP-LGHE108NTA07D 114X8059 OP-LGHE136NTA07D 114X8060 OP-LGHE215NTA07D 114X8048 OP-LGHE271NTA07D 114X8061 OP-MGZE038MTA07G R404A/R507, R134a 114X8062 OP-MGZE048MTA07D 114X8063 OP-MGZE060MTA07D 114X8064 OP-MGZE086MTA07D 114X8065 OP-MGZE108MTA07D 114X8066 OP-MGZE136MTA07D 114X8067 OP-MGZE171MTA07D 114X8068 OP-MGZE215MTA07D H D W Fig.2 Min. clearance: 2 x unit length 8 to 12 m/s at max. capacity 8 to 12 m/s at min. capacity max. 4m Silent block 1 x coil height Fig.3 Fig.4 Instructions 2 | AN293820378892en-000101 © Danfoss | DCS (CC) | 2019.01 Operating Envelop (Super heat 10K, Subcooling 0K) LGHE - NTZ (LBP Models) R404A/507 (SH10K) Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Evaporating temperature (°C) Evaporating temperature (°C) Evaporating temperature (°C) MGZE - MTZ (MBP Models) R134a (SH10K) Wiring Diagram WD1 MGZE - MTZ (MBP Models) R404A/507 (SH10K) 15 25 20 35 30 45 40 50 55 -35 -30 -25 -20 -15 -10 -5 0 5 -40 -45 15 25 20 35 30 45 40 50 55 -25 -20 -15 -10 -5 0 5 15 10 20 25 15 25 20 35 30 45 40 50 55 -30 -35 -25 -20 -15 -10 -5 0 5 15 10 D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz) D: 50Hz Voltage range 3 Phases :342V ~ 440V G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz) G: 50Hz Voltage range 1 Phase :200V ~ 264V Instructions AN293820378892en-000101 | 3 © Danfoss | DCS (CC) | 2019.01 Wiring Diagram Wiring Diagram WD2 WD3 D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz) D: 50Hz Voltage range 3 Phases :342V ~ 440V G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz) G: 50Hz Voltage range 1 Phase :200V ~ 264V D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz) D: 50Hz Voltage range 3 Phases :342V ~ 440V G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz) G: 50Hz Voltage range 1 Phase :200V ~ 264V

Optyma Blue OP-LGHE068NTA07D: Related Instructions

Manuals from Other Manufacturers