Danfoss Optyma Blue OP-LGHE068NTA07D Manuals
1 pdf manual(s) Danfoss Optyma Blue OP-LGHE068NTA07D for free download (Document Types: Instructions manual)
Available Documents for Optyma Blue OP-LGHE068NTA07D:
Brand: Danfoss
Model: Optyma Blue OP-LGHE068NTA07D
Format: PDF
Key Aspects: Best Practices for Everyday Use, Component Longevity Optimization, Standard Operating Procedures
Updated: 21.05.2026
Source File: 1768042.pdf
Pages: 8
Description: Technical setup manual for the Danfoss Optyma Blue OP-LGHE068NTA07D.
Contents
Document Preview & Text Transcription
Instructions
Optyma™ Blue
Condensing units
© Danfoss | DCS (CC) | 2019.01
AN293820378892en-000101 | 1
Code
Model Name
Refrigerant
114X8056
OP-LGHE068NTA07D
R404A/R507
114X8057
OP-LCHE096NTA07D
114X8058
OP-LGHE108NTA07D
114X8059
OP-LGHE136NTA07D
114X8060
OP-LGHE215NTA07D
114X8048
OP-LGHE271NTA07D
114X8061
OP-MGZE038MTA07G
R404A/R507,
R134a
114X8062
OP-MGZE048MTA07D
114X8063
OP-MGZE060MTA07D
114X8064
OP-MGZE086MTA07D
114X8065
OP-MGZE108MTA07D
114X8066
OP-MGZE136MTA07D
114X8067
OP-MGZE171MTA07D
114X8068
OP-MGZE215MTA07D
H
D
W
Fig.2
Min. clearance: 2 x unit length
8 to 12 m/s
at max. capacity
8 to 12 m/s
at min. capacity
max. 4m
Silent block
1 x coil height
Fig.3
Fig.4
Instructions
2 | AN293820378892en-000101
© Danfoss | DCS (CC) | 2019.01
Operating Envelop (Super heat 10K, Subcooling 0K)
LGHE - NTZ (LBP Models) R404A/507 (SH10K)
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Evaporating temperature (°C)
Evaporating temperature (°C)
Evaporating temperature (°C)
MGZE - MTZ (MBP Models) R134a (SH10K)
Wiring Diagram
WD1
MGZE - MTZ (MBP Models) R404A/507 (SH10K)
15
25
20
35
30
45
40
50
55
-35
-30
-25
-20
-15
-10
-5
0
5
-40
-45
15
25
20
35
30
45
40
50
55
-25
-20
-15
-10
-5
0
5
15
10
20
25
15
25
20
35
30
45
40
50
55
-30
-35
-25
-20
-15
-10
-5
0
5
15
10
D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz)
D: 50Hz Voltage range 3 Phases :342V ~ 440V
G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz)
G: 50Hz Voltage range 1 Phase :200V ~ 264V
Instructions
AN293820378892en-000101 | 3
© Danfoss | DCS (CC) | 2019.01
Wiring Diagram
Wiring Diagram
WD2
WD3
D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz)
D: 50Hz Voltage range 3 Phases :342V ~ 440V
G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz)
G: 50Hz Voltage range 1 Phase :200V ~ 264V
D: 380V ~ 415V/ 3P/50 HZ (Compressor 415V/3P/50Hz, Fan 415V/3P/50Hz)
D: 50Hz Voltage range 3 Phases :342V ~ 440V
G: 220V ~ 240V/ 1P/ 50 Hz (Compressor 230V/1P/50Hz, Fan 230V/1P/50Hz)
G: 50Hz Voltage range 1 Phase :200V ~ 264V