Davey HS50-06 Manuals

1 pdf manual(s) Davey HS50-06 for free download (Document Types: Installation and operating instructions)

Davey HS50-06 Installation and operating instructions Thumbnail

Davey HS50-06 Installation and operating instructions [PDF] (2 pages)

  • Identifier: id-1892090
  • Brand: Davey
  • Device: Davey HS50-06 Water Pump
  • Type: Installation and operating instructions, PDF
  • Key Aspects: Component Longevity Optimization, End-of-Life Handling and Disposal, Storage and Care Recommendations
  • UPD Date: 29.06.2026
  • Source File: 1830672.pdf
  • Pages: 2
  • Description: Comprehensive operating guide for the Davey HS50-06.
Pages Preview:
  • Davey HS50-06 Installation and operating instructions preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
AUSTRALIA Customer Service Centre 6 Lakeview Drive, Scoresby, Australia 3179 Ph: 1300 232 839 Fax: 1300 369 119 Email: [email protected] Website: daveywater.com Davey Water Products Pty Ltd Member of the GUD Group ABN 18 066 327 517 NEW ZEALAND Customer Service Centre 7 Rockridge Avenue, Penrose, Auckland 1061 Ph: 0800 654 333 Fax: 0800 654 334 Email: [email protected] Website: daveywater.com ® Davey is a registered trademark of Davey Water Products Pty Ltd. © Davey Water Products Pty Ltd 2019. Priming and Operation 1. Ensure outlet nearest to pump is open. 2. Fill pump body and suction line through priming plug hole located above suction inlet and replace plug. Please pass these instructions on to the operator of this equipment. Installation and Operating Instructions for Dynaflo HS Series Electric Pumps MODELS: HS50-06, HS60-08 Trouble Shooting Check List MOTOR OPERATING BUT NOT PUMPING 1.� Suction�line�and�pump�body�not�filled�with�water. 2. Leaking foot valve. 3.� Air�leaks�in�suction�lines�or�suction�pipe�not�under�water. 4.� Air�trapped�in�suction�lines�(also�possible�with�flooded�suction)�due�to� uneven�rise�in�piping�(eliminate�humps�and�hollows). 5.� No�water�at�source�or�water�level�too�low. 6. Valve on suction or delivery lines closed. MOTOR NOT RUNNING 1.� Power�not�connected. 2.� Supply�voltage�too�low. 3. Overload tripped. 4. Motor not free to turn e.g. a blocked impeller. 5. Internal motor fault. MOTOR RUNS FOR SOME TIME THEN STOPS - RESTARTS AUTOMATICALLY AFTER SHORT TIME Overload�tripping�in�motor� -�low�voltage�at�motor�terminals - motor in direct sunshine or in “hot box” � � -� motor�not�free�to�turn�(eg:�blocked) After Sales Service For professional after sales service or repair contact your Davey Dealer. For assistance in locating your nearest dealer contact the Davey Customer Service Centre on 1300 2 DAVEY. 3.� Switch�on. 4. Prime should establish almost immediately�with�a�strong�flow� of�water,�however,�in�some� installations it may be necessary to repeat the above operation to remove all air from the system. WARNING: DO NOT RUN DRY. DO NOT RUN WITH LOSS OF PRIME. DO NOT PUMP WATER CONTAINING ABRASIVE MATERIALS. *NOTE “MOTOR PROTECTION DEVICE” : For protection, the Davey pump motor is fitted with an automatic reset thermal overload, constant tripping of this overload indicates a problem e.g. low voltage at pump, excessive temperature (above 50°C) in pump enclosure. WARNING: Automatic reset thermal overloads will allow the pump to restart without warning. Always disconnect the pump motor from the electrical supply before maintenance or repairs. WARNING: When servicing or attending pump, always ensure power is switched off and lead unplugged. Electrical connections should be serviced only by qualified persons. Care should also be taken when servicing or disassembling pump to avoid possible injury from hot pressurised water. Unplug pump, relieve pressure by opening a tap on the discharge side of the pump and allow any hot water in the pump to cool before attempting to dismantle. IMPORTANT: DO NOT USE petroleum based fluids or solvents (e.g. Oils, Kerosene, Turpentine, Thinners, etc) on the plastic pump components or seal components. Connection of Mains Scheme or Town Water Supply to either Suction or Discharge of Pumps Most Water Supply Authorities have strict regulations regarding direct connection�of�pumps�to�mains�water�supplies.�In�most�cases�an�isolating�tank� is�required�between��mains�supply�and�pump.�Davey�also�recommend�this� method. Directly applied mains pressure can exceed pump operating pressure and damage pump. Davey Water Products Pty Ltd can not accept responsibility for loss or damage resulting from incorrect or unauthorised installations. * Installation and operating instructions are included with the product when purchased new. They may also be found on our website. P/N 402105-2 Warranty Davey Water Products Pty Ltd (Davey) warrants all products sold will be (under normal use and service) free of defects in material and workmanship for a minimum period of one (1) year from the date of original purchase by the customer as marked on the invoice, for specific warranty periods for all Davey products visit daveywater.com. This warranty does not cover normal wear and tear or apply to a product that has: • been subject to misuse, neglect, negligence, damage or accident • been used, operated or maintained other than in accordance with Davey’s instructions • not been installed in accordance with the Installation Instructions or by suitably qualified personnel • been modified or altered from original specifications or in any way not approved by Davey • had repairs attempted or made by other than Davey or its authorised dealers • been subject to abnormal conditions such as incorrect voltage supply, lightning or high voltage spikes, or damages from electrolytic action, cavitation, sand, corrosive, saline or abrasive liquids, The Davey warranty does not cover replacement of any product consumables or defects in products and components that have been supplied to Davey by third parties (however Davey will provide reasonable assistance to obtain the benefit of any third-party warranty). To make a warranty claim: • If the product is suspected of being defective, stop using it and contact the original place of purchase. Alternatively, phone Davey Customer Service or send a letter to Davey as per the contact details below • Provide evidence or proof of date of original purchase • If requested, return the product and/or provide further information with respect to the claim. Returning the product to the place of purchase is at your cost and is your responsibility. • The warranty claim will be assessed by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if: o a relevant defect is found o the warranty claim is made during the relevant warranty period; and o none of the excluded conditions listed above apply • The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organise collection of the product at their expense or authorise its disposal. If the claim is found to be valid Davey will, at its option, repair or replace the product free of charge. The Davey warranty is in addition to rights provided by local consumer law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure. For any internet connected products the consumer is responsible for ensuring a stable internet connection. In the event of a network failure the consumer will need to address the concern with the service provider. Use of an App is not a substitute for the User’s own vigilance in ensuring the product is working to expectation. Use of a Smart Product App is at the User’s own risk. To the fullest extent permitted by law Davey disclaims any warranties regarding the accuracy, completeness or reliability of App data. Davey is not responsible for any direct or indirect loss, damage or costs to the User arising from its reliance on internet connectivity. The User indemnifies Davey against any claims or legal actions from them or others relying on internet connectivity or App data may bring in this regard. Products presented for repair may be replaced by refurbished products of the same type rather than being repaired. Refurbished parts may be used to repair the products. The repair of your products may result in the loss of any user-generated data. Please ensure that you have made a copy of any data saved on your products. To the fullest extent permitted by law or statute, Davey shall not be liable for any loss of profits or any consequential, indirect or special loss, damage or injury of any kind whatsoever arising directly or indirectly from Davey products. This limitation does not apply to any liability of Davey for failure to comply with a consumer guarantee applicable to your Davey product under local laws and does not affect any rights or remedies that may be available to you under local laws. For a complete list of Davey Dealers visit our website (daveywater.com) or call:

Similar Manuals in the Water Pump Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Zoeller 71 Series

Grinder #1676JD

8 1242 249 27-05-2026 view all manuals
Eckerle EE 900M

PDF User Guide (@K654T1), Eckerle EE 900M Water Pump (16-03-2026)

20 1004 251 16-03-2026 view all manuals
ProMinent DULCOflex DFBa Series

PDF User Guide (@653MBD), ProMinent DULCOflex DFBa Series Water Pump (14-03-2026)

52 1480 326 14-03-2026 view all manuals
Liberty Pumps 406

User Guide: Liberty Pumps 406 (37HA4A, Upd.12-05-2026)

8 1004 211 12-05-2026 view all manuals
VARISCO JS Series

VARISCO JS Series User Guide (Instructions for the use and maintenance), @1L1QS5

56 1302 248 08-04-2026 view all manuals
Graco DYNAMITE 190 A Series

#O69E97: DYNAMITE 190 A Series Water Pump Instructions-parts list manual

20 1287 322 20-04-2026 view all manuals