Document Preview & Text Transcription
Anchor on the Go™
Portable Roof Anchor for Metal Roofs
Part Number 762998
Patent Number 2003258383
Installation and Operating
Instructions
WARNING: This product is part of a fall protection system. Users must read and
follow instructions in this guideline for each component of the complete system.
Manufacturer’s instructions must be followed for correct care, use and maintenance
of this product. Alterations or misuse of this product, or failure to follow instructions
may result in serious injury or death. Reading this manual of itself does not
constitute competency based training in the use of fall arrest products or systems.
2
CONTENTS
Topic
Page
General Use Warnings
3
1.0
Introduction
3
1.1
Anchor design and application
4
1.2
Strength of supporting structures
5
1.3
Recommendations
5
1.4
Assessing Fall Hazards
6
1.5
Swing Fall
6
2.0
Installation
7
2.1
Installing Anchor on the Go™ on the roof
7
2.2
Removal of Anchor on the Go™
10
3.0
Provision of Personal Protective Equipment
10
3.1
Types of PPE
10
4.0
Using Anchor on the Go™ with fall protection
equipment and warnings
11
5.0
Standards Compliance
14
5.1
Inspection, care and maintenance
14
5.2
Training in the use of fall arrest systems
14
5.3
Supervision of the use of fall arrest systems
15
6.0
Schematic drawings of anchor
15
7.0
Inspection and maintenance log
17
GENERAL USE WARNINGS
VISUALLY INSPECT TEMPORARY ANCHOR PRIOR TO, AND
FOLLOWING EACH USE, TO ENSURE IT IS IN A SERVICEABLE
CONDITION (refer to section 5.1). IF IN DOUBT, REMOVE FROM
SERVICE IMMEDIATELY.
INSTALLATION AND USE OF THIS PORTABLE ROOF ANCHOR
MUST BE PERFORMED BY, OR UNDER THE SUPERVISION OF A
COMPETENT PERSON.
DO NOT ATTACH OR USE TEMPORARY ROOF ANCHOR WITHOUT
FIRST
READING,
UNDERSTANDING
&
FOLLOWING
THESE
INSTRUCTIONS.
DO NOT USE THE PORTABLE ANCHOR FOR ANY PURPOSE OTHER
THAN FOR WHICH IT HAS BEEN DESIGNED.
PRIOR TO COMMENCEMENT OF WORK, PLEASE ENSURE THAT
YOU HAVE READ AND COMPREHENDED THE DETAIL REFERRING
TO POSITIONING OF THE ANCHOR AND THE APPROPRIATE SAFE
WORK AREA.
THIS TEMPORARY ANCHOR POINT MUST BE SUBJECTED TO A
DOCUMENTED INSPECTION EVERY 12 MONTHS BY A COMPETENT
PERSON.
1.0 INTRODUCTION
This is a Temporary Anchorage device that has been designed as a
component of a personal fall arrest system and is for use only where
there are no other practical means of connection or work practice.
Relevant State or national legislation may impose obligations to provide
safe systems of work. To discharge these responsibilities, conduct hazard
identification and risk assessment with reference to the hierarchy of
control of risks. Refer to your local State or Federal guidelines or Code of
Practice for safe work on roofs for more details.
Anchors must be properly installed prior to the operator attaching to
them and then used according to requirements contained in this manual.
3
1.1 Anchor Design and Application
The Anchor on the Go™ Portable Roof Anchor for Metal Roofs has been
designed and tested to 15kN and is therefore rated as a single person fall
arrest anchor under AS/NZS1891.4. It is only suitable for use on roofs
constructed with metal roof sheeting with a minimum BMT of 0.42mm
in the following profiles – Custom Orb, Trimdek, Spandek and Klip-Lok
406 & Klip-Lok 700 provided ridge-capping is secured in place with roof
screws per manufacturer’s instructions.
IMPORTANT: The Anchor on the Go™ Portable Roof Anchor is NOT
suitable for tiled, shingled, aluminium sheet, asbestos or decramastic
roofs.
IMPORTANT: This anchor is designed to be attached to the opposite
side of the roof from where you intend to work. Do NOT connect to or use
the anchor on the same side of the roof where the anchor is connected.
If a second person is required to work on the roof, a second anchor
device must be used. Connecting two lines to a single anchorage device is
NOT permitted. Where two connecting devices are attached to the same
anchorage point (e.g. two snap hooks), the snap hooks may rub against
each other, causing them to be entangled or even become disengaged
from the anchorage device.
Additionally, testing has concluded that whilst this device can sustain a
load of 22kN, the roof sheeting profiles most commonly used in Australia
and New Zealand will not sustain a static load greater than 15kN.
IMPORTANT: Do NOT work outside an arc of 30 degrees either side of
the centre line of the anchorage location to reduce the danger of swing
fall hazards - refer to Figure One over the page.
The user of this Anchor on the Go™ Portable Roof Anchor shall be
trained and ensure that care is taken to adjust the safety line length so
that he/she will not be able to fall off the ends of the roof.
IMPORTANT: Anchor on the Go™ Portable Roof Anchor is NOT suitable
for use as an anchorage device for a Temporary Horizontal Life Line.
4