Decora 16293 Manuals

1 pdf manual(s) Decora 16293 for free download (Document Types: Manual )

Decora 16293 Manual  Main Page Preview

Decora 16293 Manual  [PDF] (3 pages)

  • Brand: Decora
  • Model: 16293
  • Format: PDF
  • Updated: 07.08.2026

Document Preview & Text Transcription

INTRODUCTION Leviton Residential Powerline Carrier Components are designed to provide the greatest signal integrity and noise immunity possible. However, in some environments intense electrical noise can cause interference with the signal. Leviton has developed hardware and techniques for overcoming this interference when properly applied. LEVITON’S DHC DEVICES FEATURE INTELLISENSE, THE RIGHT TYPE OF AUTOMATIC GAIN CONTROL (AGC) Leviton DHC devices use Intellisense, a special gated-type of AGC, to help eliminate noise problems. This circuit feature is ideal for powerline carrier systems because it only operates during the signal window when receivers listen for command signals. Noise levels in the signal window are never as high as they are during other portions of the AC power curve. Therefore, Leviton’s Intellisense gated AGC will desensitize a receiver to noise signals with only a minimal reduction in command signal sensitivity. The result: Problems from noise interference are dramatically reduced without affecting overall system performance. It is the responsibility of the specifier/installer to test for signal strength and the presence of noise using Leviton test equipment, Cat. Nos. 6385 (Signal Test Transmitter) and 6386 (Signal Strength Indicator), and to properly apply signal coupling and noise reduction equipment according to the guidelines provided in the Decora Home Controls (DHC) Technical Manual and the DHC Troubleshooting Guide. Leviton specifically denies any warranty of performance, stated or implied, where electrical noise interference exists at the time of installation, or subsequent to installation by the addition of noise-producing devices or equipment, or where these components have been installed for non-residential applications. DHC Components are for residential use only. Installation for any other application voids any warranty, stated or implied. DESCRIPTION The Leviton Universal Switch, Cat. No. 16293, is designed for use with DHC Residential Powerline Carrier Components. Cat. No. 16293 functions as a remote switching device which responds to coded ON/OFF, and ALL LIGHTS ON/OFF commands. Cat. No. 16293 can be operated manually as a standard type switch. The switch may be set to any of 256 address codes, to be selected at the time of installation. The desired address is set by removing the switch plate and selecting letter and number codes with the tool provided. The module is equipped with six-inch leads and installs in a standard wall box. It is suitable for incandescent, fluorescent, and magnetic low-voltage lighting loads. FCC COMPLIANCE STATEMENT THIS EQUIPMENT HAS BEEN TESTED AND FOUND TO COMPLY WITH THE LIMITS FOR A CLASS B DIGITAL DEVICE, PURSUANT TO PART 15 OF THE FCC RULES. THESE LIMITS ARE DESIGNED TO PROVIDE REASONABLE PROTECTION AGAINST HARMFUL INTERFERENCE IN A RESIDENTIAL INSTALLATION. THIS EQUIPMENT GENERATES, USES, AND CAN RADIATE RADIO FREQUENCY ENERGY AND, IF NOT INSTALLED AND USED IN ACCORDANCE WITH THE INSTRUCTIONS, MAY CAUSE HARMFUL INTERFERENCE TO RADIO COMMUNICATIONS. HOWEVER, THERE IS NO GUARANTEE THAT INTERFERENCE WILL NOT OCCUR IN A PARTICULAR INSTALLATION. IF THIS EQUIPMENT DOES CAUSE HARMFUL INTERFERENCE TO RADIO OR TELEVISION RECEPTION, WHICH CAN BE DETERMINED BY TURNING THE EQUIPMENT OFF AND ON, THE USER IS ENCOURAGED TO TRY TO CORRECT THE INTERFERENCE BY ONE OR MORE OF THE FOLLOWING MEASURES: • REORIENT OR RELOCATE THE RECEIVING ANTENNA. • INCREASE THE SEPARATION BETWEEN THE EQUIPMENT AND THE RECEIVER. • CONNECT THE EQUIPMENT INTO AN OUTLET ON A CIRCUIT DIFFERENT FROM THAT TO WHICH THE RECEIVER IS CONNECTED. • CONSULT THE DEALER OR AN EXPERIENCED RADIO/TV TECHNICIAN FOR HELP. INSTALLATION INSTRUCTIONS WARNING: TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH APPROPRIATE ELECTRICAL CODES AND REGULATIONS. WARNING: IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN. WARNING: TO REDUCE THE RISK OF OVERHEATING AND POSSIBLE DAMAGE TO OTHER EQUIPMENT, DO NOT INSTALL TO CONTROL A RECEPTACLE, MOTOR-OPERATED APPLIANCE, FLUORESCENT LIGHTING FIXTURE, OR A TRANSFORMER-SUPPLIED APPLIANCE. CAUTION (For Incandescent Only): USE WITH INCANDESCENT OR 120V HALOGEN FIXTURES ONLY. CAUTION (For Magnetic Low-Voltage Only): 1. USE WITH MAGNETIC LOW-VOLTAGE TRANSFORMERS, INCANDESCENT, OR 120V HALOGEN FIXTURES ONLY. USE A LEVITON ELECTRONIC LOW-VOLTAGE DIMMER TO CONTROL ELECTRONIC (SOLID STATE) LOW- VOLTAGE TRANSFORMERS. DI-000-16293-00D Universal Switch (Single Pole or 3 Way) Rated: 10A-120VAC, 60HZ Cat. No. 16293 Incandescent: 1200W max., 60W min. – 10A, 120VAC Fluorescent: 1200VA max., 60VA min. – 10A, 120VAC Magnetic: 1200VA max., 60VA min. – 10A, 120VAC Supplemental: 1/4hp – 5.8A, 120VAC INSTALLATION INSTRUCTIONS For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com LIMITED 2 YEAR WARRANTY AND EXCLUSIONS Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such two year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise. 2. WHEN A MAGNETIC LOW-VOLTAGE CIRCUIT IS OPERATED AT A DIM LEVEL, WITH ALL LAMPS INOPERATIVE, EXCESS CURRENT MAY FLOW THROUGH THE TRANSFORMER. TO AVOID POSSIBLE TRANSFORMER FAILURE DUE TO OVERCURRENT, USE A TRANSFORMER THAT INCORPORATES THERMAL PROTECTION OR A FUSE AT THE PRIMARY WINDINGS.. OTHER CAUTIONS AND NOTES: 1. DISCONNECT POWER WHEN SERVICING FIXTURE OR CHANGING BULBS. 2. USE THIS DEVICE ONLY WITH COPPER OR COPPER CLAD WIRE. WITH ALUMINUM WIRE USE ONLY DEVICES MARKED CO/ALR OR CU/AL. 3. SAVE THIS INSTRUCTION SHEET. IT CONTAINS IMPORTANT TECHNICAL DATA ALONG WITH TESTING AND TROUBLESHOOTING INFORMATION WHICH WILL BE USEFUL AFTER INSTALLATION IS COMPLETE. TO INSTALL: 1. WARNING: TO AVOID FIRE, SHOCK, OR DEATH; TURN OFF POWER AT CIRCUIT BREAKER OR FUSE AND TEST THAT POWER IS OFF BEFORE WIRING! 2. Remove existing wallplate and switch or dimmer, if applicable. 3. Remove 3/4" (1.9 cm) of insulation from each circuit conductor. Make sure that ends of conductors are straight. 4. Connect lead wires per appropriate WIRING DIAGRAM as follows: Twist strands of each lead tightly and, with circuit conductors, push firmly into appropriate wire connector. Screw connectors on clockwise making sure that no bare conductor shows below the wire connectors. Secure each connector with electrical tape. NOTE: For single pole applications, cap YELLOW lead with an appropriate size wire connector. Secure connector with electrical tape. 5. Using a small blade screwdriver, remove the switch plate by gently prying it off (refer to Figure 1). 6. Using the tool provided, set the House Code Dial Letter and the Unit Code Dial Number to the desired code (refer to Figure 2). 7. If it is desirable to change the color of the device, do so now by following the “Color Conversion Procedure”. 8. Mount device “TOP” up to wall box. 9. Restore power at circuit breaker or fuse. INSTALLATION IS COMPLETE. COLOR CONVERSION PROCEDURE The color of Cat. Nos. 16293 can be changed to suit your interior design requirements. Simply obtain a color conversion kit of the appropriate color from your Leviton distributor or use the one provided, and proceed as follows: 1. The switch plate has snaps on its sides. Place the tip of a small-bladed screwdriver under a snap and gently pry off the switch plate (refer to Figure 1). 2. Take the new switch plate and position it properly to the strap. Notice that the switch plate has an A/C indicator light at one end. The switch plate should be installed with the A/C indicator light positioned at the bottom. With the switch plate properly positioned, gently press it into place until it seats properly with a click. The color conversion is complete. H Controls ome ecora D DI-000-16293-00D Command Signal is picked up Gated AGC ignores High noise levels outside signal window Noise is not picked up Signal Window Signal Window Receiver sensitivity with Intellisense gated AGC Figure 1 – Switch Plate Removal Switch Plate Strap Push in 2 Locations (see arrows) AC Indicator Light Figure 2 – Dimmer Functions Unit Code Dial House Code Dial Adjustment Tool DI-000-16293-00D 2/7/01, 3:55 PM 1

Decora 16293: Switch Category Related Instructions

Cisco AVS 3120 Hardware installation manual
Cisco AVS 3120
27.06.2026 76 pages

Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 USA http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883 Cisco Catalyst Blade Switch 3120 for HP Hardware Installation Guide March 2008 THE SPECIFIC

TRENDnet TFC-1600MM Operation & user’s manual
TRENDnet TFC-1600MM
05.07.2026 30 pages

TRENDnet User’s Guide Cover Page

Lindy 3 Port Operation & user’s manual
Lindy 3 Port
14.08.2026 2 pages

3 Port HDMI Switch User Manual English LINDY No. 38033 www.lindy.com Introduction Thank you for purchasing the LINDY 3 Port HDMI Switch. This switch allows you to connect three HDMI devices to a single HDMI equipped TV or projector and then switch between

HP Photosmart 7510 Specifications
HP Photosmart 7510
29.06.2026 2 pages