Delta Electronics Programmablelogic Controller DVP-Slim Manuals

1 pdf manual(s) Delta Electronics Programmablelogic Controller DVP-Slim for free download (Document Types: Instruction sheet)

Delta Electronics Programmablelogic Controller DVP-Slim Instruction sheet Thumbnail

Delta Electronics Programmablelogic Controller DVP-Slim Instruction sheet [PDF] (2 pages)

  • Identifier: id-218471
  • Brand: Delta Electronics
  • Device: Delta Electronics Programmablelogic Controller DVP-Slim Switch
  • Type: Instruction sheet, PDF
  • Key Aspects: Information on Regular Maintenance, Troubleshooting Information, Storage and Care Recommendations
  • UPD Date: 30.05.2026
  • Source File: 154788.pdf
  • Pages: 2
  • Description: Comprehensive instruction manual for the Delta Electronics Programmablelogic Controller DVP-Slim.
Pages Preview:
  • Delta Electronics Programmablelogic Controller DVP-Slim Instruction sheet preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
http://www.delta.com.tw/industrialautomation/ 5011658300-MNE0 2007-01-23 Digital I/O Extension Unit (Pin Headed) Instruction Sheet Warning 3 Please read this instruction sheet carefully before use. 3 DVP-Slim is an OPEN-TYPE device and therefore should be installed in an enclosure free of airborne dust, humidity, electri shock and vibration. The enclosure should prevent non-maintenance staff from operating the device (e.g. key or specific tools are required to open the enclosure) in case danger and damage on the device may occur. 3 DO NOT connect input AC power supply to any of the I/O terminals; otherwise serious damage may occur. Check all the wiring again before switching on the power. DO NOT touch any terminal when the power is switched on. X Introduction 1.1 Model Explanation & Peripherals Thank you for choosing Delta DVP-Slim series programmable logic controller. DVP-Slim series pin-headed digital I/O extension unit offers 32 points. For DVP-SS/SA/SX/SC series MPU, the maximum digital I/O extension points (including the MPU) can reach 128 points. For SV series MPU, the maximum digial I/O extension points (including the MPU) can reach 256 points. In addition, maximum 8 additional special modules (AD/DA/PT/TC/XA/PU) can be extended to DVP-Slim series extension unit. Nameplate Explanation VX.XXAX 24Vdc 1W 0.1A(24VDC)POINT M A D E I N X X X X X 32SN11TNT7020001 Delta PLC model name Power input spec. Output point module spec. Barcode & serial No. Version Model Name Serial No. Input point extension unit Output point extension unit M: N: DVP series Points (32 for output) Module type TN: N: NPN transistor No output module DC power input Production No. Model name Production week Production year (2007) Production plant 1.2 Product Profile Unit: mm c POWER, L.V (low voltage) indicator h Extension unit positioning hole d Model name i Nameplate e Extension unit fixing clip j Extension unit fixing clip f I/O terminals k DIN rail (35mm) g DIN rail clip l Connection port for extension unit 1.3 Model Information Input Output Model name Power supply Points Type Points Type Dimension (mm) Outline DVP32SM11N 32 DC Type Sink/Source 0 N/A DVP32SN11TN 24V DC 0 N/A 32 (NPN) Transistor 25.2 90 60 Y Specifications 2.1 Electrical Specifications Model Item DVP32SM11N DVP32SN11TN Power supply voltage 24V DC (-15% ~ 20%) (with DC input polarity reverse protection) Motion specification Within 5ms of the momentary power loss, the device will keep on operating. Power consumption 1W 1.5W Insulation resistance >5 MΩ (all I/O point-to-ground: 500V DC) Noise immunity ESD (IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV, Analog & Communication I/O: 1KV Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m Earth The diameter of grounding wire shall not be less than that of L, N terminal of the power. (When many PLCs are in use at the same time, please make sure every PLC is properly grounded.) Operation/storage environment Operation: 0ºC ~ 55ºC (temperature); 50 ~ 95% (humidity); pollution degree 2 Storage: -40ºC ~ 70ºC (temperature); 5 ~ 95% (humidity) Shock/vibration immunity International standards: IEC1131-2, IEC 68-2-6 (TEST Fc)/IEC1131-2 & IEC 68-2-27 (TEST Ea) Weight (g) 70g 70g 2.2 I/O Point Specifications Input Point Input type DC (SINK or SOURCE) Input current 24VDC, 5mA Active level Off Æ On more than 16V DC On Æ Off less than 14.4V DC Response time Approx. 10ms, 0 ~ 15ms adjustable from D1020, D1021 Circuit isolation / operation instruction By photocoupler / LED On Output Point Output type Transistor – T (NPN) Current specification 0.1A/point Voltage specification 5 ~ 24 VDC Maximum load 55ºC/1A (COM), 25ºC/2.4A (COM) Response time Off Æ On less than 0.1ms On Æ Off less than 0.3ms Z Installation & Wiring 3.1 Terminals of Digital I/O Extension Unit DVP32SM11N DVP32SN11TN 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 X21 X23 X25 X27 X31 X33 X35 X37 S/S NC X1 X3 X5 X7 X11 X13 X15 X17 S/S NC X20 X22 X24 X26 X30 X32 X34 X36 S/S NC X0 X2 X4 X6 X10 X12 X14 X16 S/S NC DVP32SM 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Y21 Y23 Y25 Y27 Y31 Y33 Y35 Y37 GND +24V Y1 Y3 Y5 Y7 Y11 Y13 Y15 Y17 GND +24V Y20 Y22 Y24 Y26 Y30 Y32 Y34 Y36 GND +24V Y0 Y2 Y4 Y6 Y10 Y12 Y14 Y16 GND +24V DVP32SN ƒ DVP32SN currently only offers TN (NPN) transistor output. ƒ Please be aware of the following PIN wiring methods for DVP32SN to prevent burn-down of the extension unit. 1. PIN19, PIN20, PIN39 and PIN40 can only connected to +24V DC. The 4 points have already been designed as short-circuit within the extension unit; therefore only 1 of the points needs to be wired. 2. PIN17, PIN18, PIN37 and PIN38 can only connected to GND. The 4 points have already been designed as short-circuit within the extension unit; therefore only 1 of the points needs to be wired. 3.2 Connection Step 1: Screw open the side cover of the extension unit and you will see the connection port. Step 2: Lift the fixing clip by the screwdriver. Step 3: Adjust the positioning hole of the MPU and the extension unit and meet the connection port on the MPU with the extension unit to tightly connect the two. Step 4: Fasten the fixing clip on the extension unit to complete the connection. 3.3 Installation & Wiring Install the PLC in an enclosure with sufficient space around it to allow heat dissipation as shown in the figure below. DVP MPU D D D D D > 50mm

Similar Manuals in the Switch Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
H3C S3600 Series

#B91WF1: S3600 Series Network Router Operation manual

37 421 64 02-07-2026 view all manuals
ANTAIRA LNX-602N

Switch #873G6V

39 41 10 13-03-2026 view all manuals
LEGRAND 3440

Home Automation #FZ725Q

518 101 18 03-07-2026 view all manuals
Superrollo GW60

Superrollo GW60 Manual (Installation and operating instructions manual), @HQ7R69

250 630 108 04-07-2026 view all manuals
Siemens Sivacon S8

Switch #24336F

63 339 51 05-05-2026 view all manuals
H3C S9500 Series

#82696Y: S9500 Series Switch Command manual

11 108 27 17-03-2026 view all manuals