Delta PMC Series Manuals

5 pdf manual(s) Delta PMC Series for free download (Document Types: Instruction manual)

Delta PMC Series Instruction manual [PDF] (2 pages)

  • Identifier: id-1900753
  • Brand: Delta
  • Device: PMC Series Power Supply
  • Type: PDF
  • Key Aspects: Device Specifications Overview, Cleaning and Sanitization Methods, System Connectivity and Wiring Basics
  • UPD Date: 17.03.2026
  • Source File: 1822008.pdf
  • Pages: 2
  • Description: User support manual for the Delta PMC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Instruction Manual PMC-24V600W1RW www.DeltaPSU.com 1. Safety Instructions • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 50mm from all ventilated surfaces while the device is in operation. • The device is not recommended to be placed on low thermal conductive surface, for example, plastics. • Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! • Do not touch the terminals while power is being supplied. Risk of electric shock. • Prevent any foreign metal, particles or conductors from entering the device through the openings during installation. It may cause: Electric shock; Safety Hazard; Fire; Product failure • Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. 2. Device Descriptions Refer to Fig. 1.: � Input terminal block connector � Output terminal block connector � DC voltage adjustment potentiometer � Signal Connector � DC OK control LED (Green) ⑥ DC Fan 3. Installation of the Device The unit is protected with internal fuse (not replaceable) at L pin and it has been tested and approved on 20A (UL) and 16A (IEC) branch circuits without additional protection device. Refer to Fig. 2.: � Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 4 mounting holes using M4 screw. � Input / Output connector � This surface belongs to customer's end system or panel where the power supply is mounted. • Use flexible cable (stranded or solid) of AWG No. 14-10. The torque at the Input connector shall not exceed 11.98Kgf.cm. The torque at the Output connector shall not exceed 16.59Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm (Refer to Fig. 3). 4. Installation of Mounting Accessories Refer to Fig. 4.: • Only use M4 screw ≤ 4.5mm through the base mounting holes. This is to keep a safe distance between the screw and internal components. • Recommended mounting torque for tightening: 4~8Kgf.cm. 5. Input Voltage Derating Curve • Output derating is required at 85-110Vac (Refer to Fig. 5). 6. Maximum 5000 Meters Operating Altitude REV. 00 Fig. 1. Device Descriptions Fig. 3. Wire Type Fig. 4. Mounting Screw Fig. 5. Input Voltage Derating Curve Fig. 2 Mounting Orientations Side Mounting Base Mounting (Horizontal) Base Mounting (Vertical) Base Mounting (Vertical) Stripped Wire Lug Mounting accessories Mounting screw Chassis of the device Xmm max. 80 100 85 11 Load (%) (Vac) 7mm max. 4.5mm max. A C B A C B Air flow direction Base surface Top surface Side surface 1 2 3 4 5 6 A B C A B C 0

Delta PMC Series Instruction manual [PDF] (2 pages)

  • Identifier: id-2222633
  • Brand: Delta
  • Device: PMC Series Power Supply
  • Type: PDF
  • Key Aspects: Basic Configuration Guidelines, Product Performance Metrics, Troubleshooting Information
  • UPD Date: 15.04.2026
  • Source File: 2064999.pdf
  • Pages: 2
  • Description: Usage and setup manual for the Delta PMC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Instruction Manual PMC-05V050W1AA www.DeltaPSU.com 1. Safety Instructions • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm from all ventilated surfaces while the device is in operation. • The device is not recommended to be placed on low thermal conductive surface, for example, plastics. • Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! • Do not touch the terminals while power is being supplied. Risk of electric shock. • Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure • Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. • Nominal input voltage: 100-240Vac or 125-250Vdc Voltage range: 90-264Vac or 120-375Vdc 2. Device Descriptions Refer to Fig. 1.: 䐟 Input & Output terminal block connector 䐠 DC voltage adjustment potentiometer 䐡 DC OK control LED (Green) 3. Installation of the Device Refer to Fig. 2.: 䑵 Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. 䑶 This surface belongs to customer’s end system or panel where the power supply is mounted. 䑷 Connector • Use flexible cable (stranded or solid), AWG No. 20-14. The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm (Refer to Fig. 3). 4. Installation of Mounting Accessories Refer to Fig. 4.: • Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a safety distance between the screw and internal components. • Recommended mounting tightening torque: 4~8 Kgf.cm. REV.01 Fig. 1. Device Descriptions Fig. 3. Wire Type Fig. 4. Mounting Screw Lug Stripped wire Mounting accessories Mounting screw Chassis of the device 6mm max. 7 mm Fig. 2. Mounting Orientation Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal) Side Surface Top Surface Ventilated Surface Base Surface 1 2 3 B C A A C B B A C B C A A C B B A C B C A A C B B A C

Delta PMC Series Instruction manual [PDF] (2 pages)

  • Identifier: id-2222634
  • Brand: Delta
  • Device: PMC Series Power Supply
  • Type: PDF
  • Key Aspects: Warranty and Service Information, Cleaning and Sanitization Methods, Best Practices for Everyday Use
  • UPD Date: 22.04.2026
  • Source File: 2064998.pdf
  • Pages: 2
  • Description: Manual for installation and usage of the Delta PMC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Instruction Manual PMC-05V035W1A□ www.DeltaPSU.com 1. Safety Instructions • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm from all ventilated surfaces while the device is in operation. • The device is not recommended to be placed on low thermal conductive surface, for example, plastics. • Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! • Do not touch the terminals while power is being supplied. Risk of electric shock. • Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure • Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. • Nominal input voltage: 100-240Vac or 125-250Vdc Voltage range: 90-264Vac or 120-375Vdc 2. Device Descriptions Refer to Fig. 1.: 䐟 Input & Output terminal block connector 䐠 DC voltage adjustment potentiometer 䐡 DC OK control LED (Green) 3. Installation of the Device Refer to Fig. 2.: 䑵 Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. 䑶 This surface belongs to customer’s end system or panel where the power supply is mounted. 䑷 Connector • Use flexible cable (stranded or solid) with the following sizes: • The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm (Refer to Fig. 3). 4. Installation of Mounting Accessories Refer to Fig. 4.: • Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a safety distance between the screw and internal components. • Recommended mounting tightening torque: 4~8 Kgf.cm. REV.01 Fig. 1. Device Descriptions PMC-05V035W1AA (Standard Connector) PMC-05V035W1AJ (IP20 Connector) Fig. 3. Wire Type Fig. 4. Mounting Screw Lug Stripped wire Mounting accessories Mounting screw Chassis of the device 6mm max. 7 mm Fig. 2. Mounting Orientation Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal) PMC-05V035W1AA PMC-05V035W1AJ AWG 20-14 AWG 20-12 Side Surface Top Surface Ventilated Surface Base Surface 1 2 3 Side Surface Top Surface Ventilated Surface Base Surface 1 2 3 B C A A C B B A C B C A A C B B A C B C A A C B B A C

Delta PMC Series Instruction manual [PDF] (2 pages)

  • Identifier: id-2222635
  • Brand: Delta
  • Device: PMC Series Power Supply
  • Type: PDF
  • Key Aspects: System Connectivity and Wiring Basics, End-of-Life Handling and Disposal, Operational Mode Explanations
  • UPD Date: 03.09.2026
  • Source File: 2064997.pdf
  • Pages: 2
  • Description: Essential instructions for the Delta PMC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Instruction Manual PMC-24V035W1A□ www.DeltaPSU.com 1. Safety Instructions • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm from all ventilated surfaces while the device is in operation. • The device is not recommended to be placed on low thermal conductive surface, for example, plastics. • Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! • Do not touch the terminals while power is being supplied. Risk of electric shock. • Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure • Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. 2. Device Descriptions Refer to Fig. 1.: 䐟 Input & Output terminal block connector 䐠 DC voltage adjustment potentiometer 䐡 DC OK control LED (Green) 3. Installation of the Device Refer to Fig. 2.: 䑵 Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. 䑶 This surface belongs to customer’s end system or panel where the power supply is mounted. 䑷 Connector • Use flexible cable (stranded or solid), AWG no. 20-12. The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm (Refer to Fig. 3). 4. Installation of Mounting Accessories Refer to Fig. 4.: • Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a safety distance between the screw and internal components. • Recommended mounting tightening torque: 4~8 Kgf.cm. REV.03 Fig. 1. Device Descriptions PMC-24V035W1AA (Standard Connector) PMC-24V035W1AJ (IP20 Connector) Fig. 3. Wire Type Fig. 4. Mounting Screw Lug Stripped wire Mounting accessories Mounting screw Chassis of the device 6mm max. 7 mm Fig. 2. Mounting Orientation Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal) Side Surface Top Surface Ventilated Surface Base Surface 1 2 3 PMC-24V035W1AL (Front Face Connector) 1 2 3 1 2 3 B C A A C B B A C B C A A C B B A C B C A A C B B A C

Delta PMC Series Instruction manual [PDF] (2 pages)

  • Identifier: id-2222636
  • Brand: Delta
  • Device: PMC Series Power Supply
  • Type: PDF
  • Key Aspects: Troubleshooting Information, Recommended Spare Parts List, Component Overview and Descriptions
  • UPD Date: 02.04.2026
  • Source File: 2064996.pdf
  • Pages: 2
  • Description: Detailed operating instructions for the Delta PMC Series.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Instruction Manual PMC-24V050W1A□ www.DeltaPSU.com 1. Safety Instructions • To ensure sufficient convection cooling, always maintain a safety distance of ≥ 20mm from all ventilated surfaces while the device is in operation. • The device is not recommended to be placed on low thermal conductive surface, for example, plastics. • Note that the enclosure of the device can become very hot depending on the ambient temperature and load of the power supply. Do not touch the device while it is in operation or immediately after power is turned OFF. Risk of burning! • Do not touch the terminals while power is being supplied. Risk of electric shock. • Prevent any foreign metal, particles or conductors to enter the device through the openings during installation. It can cause: Electric shock; Safety Hazard; Fire; Product failure • Warning: When connecting the device, secure Earth connection before connecting L and N. When disconnecting the device, remove L and N connections before removing the Earth connection. 2. Device Descriptions Refer to Fig. 1.: 䐟 Input & Output terminal block connector 䐠 DC voltage adjustment potentiometer 䐡 DC OK control LED (Green) 3. Installation of the Device Refer to Fig. 2.: 䑵 Mounting holes for power supply assembly onto the mounting surface. The power supply shall be mounted on minimum 2 mounting holes using M3 screw minimum 5mm length. 䑶 This surface belongs to customer’s end system or panel where the power supply is mounted. 䑷 Connector • Use flexible cable (stranded or solid), AWG no. 20-12. The torque at the Connector shall not exceed 13 Kgf.cm. The insulation stripping length should not exceed 0.275” or 7mm (Refer to Fig. 3). 4. Installation of Mounting Accessories Refer to Fig. 4.: • Only use M3 screw ≤ 6mm through the base mounting holes. This is to keep a safety distance between the screw and internal components. • Recommended mounting tightening torque: 4~8 Kgf.cm. REV.03 Fig. 1. Device Descriptions PMC-24V050W1AA (Standard Connector) PMC-24V050W1AJ (IP20 Connector) Fig. 3. Wire Type Fig. 4. Mounting Screw Lug Stripped wire Mounting accessories Mounting screw Chassis of the device 6mm max. 7 mm Fig. 2. Mounting Orientation Side Mounting (Vertical) Base Mounting (Vertical) Side Mounting (Horizontal) Side Surface Top Surface Ventilated Surface Base Surface 1 2 3 PMC-24V050W1AL (Front Face Connector) 1 2 3 1 2 3 B C A A C B B A C B C A A C B B A C B C A A C B B A C

Delta PMC Series: Power Supply Category Related Instructions

MERLIN STEALTH MASTER
Nemtek MERLIN STEALTH MASTER
08.04.2026 25 pages

INSTALLERS MANUAL Revision 1.5 23 February 2007 GROUP OF COMPANIES MERLIN STEALTH – Electric Fence Energizer User and installation guide for the Nemtek MERLIN STEALTH MASTER Power Supply. The manual contains instructions for system parameters, regulatory notices, firmware installation.

CA-300
Coolmax CA-300
29.04.2026 4 pages

Model: CA-300 1. Function Description This power supply is designed for personal computer. There are six DC outputs: +5V, -5V, +12V, -12V, +3.3V& +5VSB , and it provides power to all computer systems and peripherals with maximum protection. Here are some of User guide for the Coolmax CA-300 Power Supply. It explains configuration options and installation, security instructions, device operation tips.

HCG-520
Antec HCG-520
26.08.2026 6 pages

HCG-520 POWER SUPPLY USER’S MANUAL Manual for installation and usage of the Antec HCG-520 Power Supply. It provides detailed operation instructions and supported accessories, support details, software configuration.

Cordless Hand Vac LiNX
Hoover Cordless Hand Vac LiNX
26.07.2026 3 pages

MODE D’EMPLOI • Veuillez lire attentivement ces instructions avant d’utiliser votre aspirateur vertical HOOVERMD. • Nous pouvons vous aider à assembler cet appareil et répondre à vos questions, pour cela composez le : 1-877-697-5866 (Canada et Ét Product documentation for the Hoover Cordless Hand Vac LiNX Vacuum Cleaner. The manual outlines system configuration and maintenance procedures, error codes, cleaning instructions.