The D1000
Installation and
Service Manual
Version 2.1
The D1000
Installation and
Service
Version 2.1
1
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PER-
SONS, OBSERVE THE FOLLOWING:
1.
Use this unit only in the manner intended by the manufacturer. If you
have questions, contact the manufacturer at the address or telephone
number listed on the front cover of this manual.
2.
Before servicing or cleaning unit, switch power off at service panel and
lock the service disconnecting means to prevent power from being
switched on accidentally. When the service disconnecting means can-not
be locked, securely fasten a prominent warning device, such as a tag, to
the service panel.
3.
Installation work and electrical wiring must be done by a qualified per-
son(s) in accordance with all applicable codes and standards, in-cluding
fire-rated construction codes and standards.
4.
Sufficient air is needed for proper combustion and exhausting of gases
through the flue (chimney) of fuel burning equipment to prevent back-
drafting. Follow the heating equipment manufacturer’s guideline and
safety standards such as those published by the National Fire Protection
Association (NFPA), and the American Society of Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE), and the local code authori-
ties.
5.
When cutting or drilling into wall or ceiling, do not damage electrical
wiring and other hidden utilities.
6.
To reduce the risk of fire or electric shock, do not use this range hood
with an additional speed control device.
7.
Ducted fans must always be vented to the outdoors.
8.
To reduce the risk of fire, use only metal ductwork.
9.
Use with approved wiring only.
10. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1.
Never leave surface units unattended at high settings. Boilovers cause
smoking and greasy spillovers that may ignite. Heat oils slowly on low or
medium settings.
2.
Always turn hood ON when cooking at high heat or when cooking flaming
foods.
3.
Clean ventilating fans frequently. Grease should not be allowed to accu-
mulate on fan or filter.
4.
Use proper pan size. Always use cookware appropriate for the size of the
surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A
RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1.
SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray,
then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the
flames do not go out immediately, EVACUATE AND CALL THE FIRE
DEPARTMENT.
2.
NEVER PICK UP A FLAMING PAN — You may be burned.
3.
DO NOT USE WATER, including wet dishcloths or towels - violent steam
explosion will result.
4.
Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you already know
how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
WARNING
1.
For general ventilating use only. Do not use to exhaust hazardous or
explosive materials and vapors.
2.
To avoid motor bearing damage and noisy and/or unbalanced impel-
lers, keep drywall spray, construction dust, etc. off power unit.
3.
For best capture of cooking impurities and performance of fire extin-
guisher, your range hood should be mounted so that the bottom of
the hood is 18-30” above the cooking surface, depending on model.
4.
Please read specification sheets for further information and require-
ments.
!
CAUTION
TABLE OF CONTENTS
READ AND SAVE THESE INSTRUCTIONS
1. System Anatomy
pg 2
2. Sample Elevations
pg 3
3. Preparing thr Install location
pg 5
4. Range Element Disconnect install
pg 8
5. Installing The D1000
pg 10
6. Fire Alarm System Connections
pg 11
7. Manual Pull Station Installation
pg 12
8. Test Tank & Demonstration
pg 13
9. Electrical Schematic
pg 14
10. Accessing The Interals
pg 16
11. Maintnence
pg 17
12. D1000 Operating System
pg 19
13. PLC Schematic
pg 22
14. After an Actuation
pg 24
15. Ducting and Airflow
pg 27
16. Spare Parts
pg 28
17. Warranty Statement
pg 29
18. NFPA101 -F & -R Installation
Appendix A
DISCLAIMER: Denlar Fire Protection LLC, shall not be liable for errors contained in this
Manual or for incidental, consequential damages in connection with the furnishing,
performance or use of this information. Denlar Fire Protection makes no warranty
of any kind with regard to this information, including, but not limited to the implied
warranties of merchantability and fitness for a particular purpose.
The D1000
Installation and
Service
Version 2.1
2
System Anatomy
Recirculating Vent
(recirculating model)
Power Switch
Reset Switch
Extinguisher Pressure Gauge
Electrical Disconnect (Black Tape)
110 VAC Power Supply (Red Tape)
Junction Box
Thumbscrew (to remove vent) -on some models
Thumbscrews (2x) (inline models)
Back Support Mounting Bracket
Fan Speed Knob
Light Switch
Discharge Nozzles
(with protective caps)
Fusible Link
Light Bulb
Low Temperature Switches
High Temperature
Switch
Thumb Nut (3x)
Grease Tray
Grease Filter
LED Status Light