Det-Tronics X Series Manuals

2 pdf manual(s) Det-Tronics X Series for free download (Document Types: Addendum, Instructions manual)

Det-Tronics X Series Addendum Main Page Preview

Addendum [PDF] (16 pages)

  • Updated: 03.06.2026

Document Preview & Text Transcription

1.1 95-8790 Addendum Det-Tronics X-Series Flame Detectors with Pulse Output Table of Contents DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . 1 Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 oi (Optical Integrity) . . . . . . . . . . . . . . . . . 2 GENERAL APPLICATION INFORMATION . . 3 Response Characteristics. . . . . . . . . . . . . 3 Important Application Considerations . . . 3 IMPORTANT SAFETY NOTES . . . . . . . . . . . 3 WIRING PROCEDURE . . . . . . . . . . . . . . . . . 3 Wire Size and Type . . . . . . . . . . . . . . . . . . 3 Detector Wiring . . . . . . . . . . . . . . . . . . . . . 4 STARTUP PROCEDURE. . . . . . . . . . . . . . . 10 Manual oi Test (Output to Controller) . . 10 Count Test Mode (Output to Controller) . 10 Fire Alarm Test (Pulse Output to Fire Alarm Panel). . . . . 10 MAINTENANCE. . . . . . . . . . . . . . . . . . . . . . 11 Periodic Checkout Procedure. . . . . . . . . 11 Certification. . . . . . . . . . . . . . . . . . . . . . . 11 MODEL MATRIX . . . . . . . . . . . . . . . . . . . . . 12 1 95-8790 1.1 WARNING Be sure to read and understand the entire instruction manual before installing or operating the flame detection system. Any deviation from the recommendations in this manual may impair system performance and compromise safety. ATTENTION The X-Series flame detectors include the Automatic oi ® (Optical Integrity) feature — a calibrated performance test that is automatically performed once per minute to verify complete detector operation capabilities. Testing with an external test lamp is not approved or required. DESCRIPTION The X3301, X3302, X2200, X5200, and X9800 (X-Series) series flame detectors with pulse/relay output are designed for use in controller based systems. In addition to use in new systems, they can serve as a direct field replacement for Det- Tronics controller based flame detectors that generate a pulse output (not compatible with R7484 and R7409B/C). When used as a field replacement, all operating features of the current controller are retained in addition to gaining the advanced features of the X-Series Flame Detector. In typical applications, the four wire detector can utilize all existing system wiring. This addendum provides details on the pule/ relay output communication of the X-Series flame detectors. See each models individual instruction manual for installation, operational, and troubleshooting details: X3301 Series - 95-8704 or 95-8527 X3302 Series - 95-8768 or 95-8576 X2200 Series - 95-8549 X5200 Series - 95-8546 X9800 Series - 95-8554 ADDENDUM Det-Tronics X-Series Flame Detectors with Pulse Output ©2020 Carreir. All rights reserved. Last Manual Update: 7/15/19

Document Preview & Text Transcription

3.1 95-8751 Instructions Enhanced Flame Inspector Software for use with Det-Tronics X-Series Flame Detectors Table Of Contents DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 FEATURES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 HARDWARE REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 DETERMINING DETECTOR CONFIGURATION AND PROGRAMMING . . . 8 DETERMINING CURRENT STATUS CONDITIONS . . . . . . . . . . . . . . . . . . 8 MANUAL oi TEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Manual oi Initiated by Magnet / Switch . . . . . . . . . . . . . . . . . . . . . . . . 8 Manual oi Test Initiated by Enhanced Flame Inspector . . . . . . . . . . . 9 oi CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 4-20 mA TEST / CALIBRATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 MONITORING THE DETECTOR’S EVENT LOGS . . . . . . . . . . . . . . . . . . 12 Sort Order . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Saving Files . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Event Logs Descriptions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 REPLACEMENT PARTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 ORDERING INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 DESCRIPTION Det-Tronics X-Series Flame Detectors record pertinent configuration and event information in the device’s non- volatile memory. Important detector status data such as power-up/down, faults and alarms are date and time stamped as they occur and stored in the electronic module located inside the detector enclosure. The Inspector Monitor software allows the user to later upload this data to a personal computer (PC) where it can be displayed, saved and/or printed. Enhanced Flame Inspector Software is compatible with all versions of X3301, X3302, X9800, X5200 and X2200 flame detectors. FEATURES • Data logging capability for Det-Tronics flame detectors. • Data stored in non-volatile memory. • Data can be uploaded to a PC. • Data can be viewed, stored to a file, or printed. HARDWARE REQUIREMENTS Enhanced Flame Inspector software is designed for PCs using the Windows operating system. A minimum of 16 megabytes of RAM are required; however, 32 or more megabytes are recommended for optimum performance. The software requires a color monitor with a minimum resolution of 640 by 480. A hard drive with at least 10 megabytes of free space is also required. The system can utilize any properly installed printer. INSTALLATION WIRING Hardwired Method It is recommended to connect the detector’s RS-485 terminals (terminals 23 and 24) to the PC at the time of installation. This will allow Inspector Monitor to function at any time, without the need to open the detector housing and remove the sensor module (“front” half of the detector) prior to test. A RS-485 to USB converter (p/n 103881-001) is required for proper communication. INSTRUCTIONS Enhanced Flame Inspector Software for use with Det-Tronics X-Series Flame Detectors 3 .1 ©Detector Electronics Corporation 2019 95-8751 Last Manual Update: 12/18/19 NOTE Changing the detectors settings could result in a configuration that has not been 3rd party performance approved. IMPORTANT! For flame detectors with LON output, the EQP controller will override any settings made with the Enhanced Flame Inspector software, with the exception of the Hangar Mode on the X3301. 2 95-8751 3.1 NOTE The PC must always be located in a non- hazardous controlled location. Modbus communications are only available on X-series detectors that have Relay, Relay/4-20mA, and Pulse outputs. Modbus communications are not available on X-series detectors that have HART or EQP outputs. NOTE Communication between the sensor module and the PC uses the Modbus RTU protocol, with the sensor module configured as a Modbus slave. Alternate Method NOTE The alternate method must be used with EQP and HART models since these detectors are not furnished with RS-485 output terminals. This method requires removal of the sensor module from the detector housing for testing in a control room. A 5/64 inch Allen wrench is needed to loosen the lock screw when removing the module. To remove the sensor module follow these steps: 1. Remove power from the detector. 2. Using the allen wrench supplied with the detector, loosen the locking screw on the side of the housing. 3. Unscrew the sensor module and remove it from the front of the detector housing. WARNING Do not open the detector assembly in a hazardous area when power is applied. Connector includes a power supply that can plug into any standard 120/240 vac outlet. The Inspector Connector utilizes an integral RS-485 to USB converter (see Figure  2) to ensure proper communication. Connect the converter end of the Inspector Connector to the USB port of the PC. Connect the end with the power supply connection to the sensor module (see Figure 3). CONNECT THIS END OF INSPECTOR CONNECTOR TO THE PC USB PORT. CONNECT THIS END TO THE SENSOR MODULE. A2485 Figure 1— Removing the Sensor Module Figure 2—Inspector Connector with RS-485 to USB Converter Figure 3—Connecting Inspector Connector to sensor module