Document Preview & Text Transcription
WARNING
!
!
Improper installation, adjustment, alteration, service or maintenance can cause
property damage, injury or death. Read the installation, operation and maintenance
instructions thoroughly before installing or servicing this equipment.
This heater must be installed and serviced by trained gas installation and service
personnel only. Failure to comply could result in personal injury, asphyxiation, death,
fire or property damage.
In locations used for the storage of combustible materials, signs must be posted to
specify the maximum permissible stacking height to maintain the required clearances
from the heater to the combustibles. Signs must either be posted adjacent to the
heater thermostats or in the absence of such thermostats, in a conspicuous location.
Not for residential use! Do not use this heater in the home, sleeping quarters,
attached garages, etc. Installation of a commercial tube heater system in residential
indoor spaces may result in property damage, serious injury, asphyxiation or death.
AG2 Series
Insert Manual
For complete installation instructions, see the Tube Heater General Manual
that accompanies this Series Insert Manual.
The AG2 Series Infra-Red Tube Heater is a positive pressure, two-stage radiant heater system. This insert
manual is a supplement to the Tube Heater General Manual and provides specific information related to
the AG2 Series model. All persons involved with the installation, operation and maintenance of the heater
system must read and understand the information in this insert manual and the accompanying Tube
Heater General Manual.
For Your Safety
If you smell gas:
• Do not try to light any appliance.
• Immediately call your gas supplier from a neighbor’s phone.
• Do not touch any electrical switch.
• Follow the gas supplier’s instructions.
• Do not use any phone in your building. • If you cannot reach your gas supplier, call the fire department.
Keep these instructions for future reference.
F/N: LIOAG2a-3M-5/07 (MWG)
Replaces F/N: LIOAG2-2M-2/06
Contents
1.0 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Safety Labels and Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Clearance to Combustibles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
2.0 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Combustion Air . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Electrical Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Tube Installation Sequence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.0 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Sequence of Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
4.0 Troubleshooting Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
5.0 Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Parts List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Kit Contents Check List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Approvals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
NOTE: See page 10 for a list of available models and specifications.
2
AG2 Series
1.0 Safety
Manifold Pressure
Max. Inlet Pressure
Min. Inlet Pressure for
Purpose of Input Adjustment
Min. Mounting Angle
Max. Mounting Angle
Combustion Chamber
W.C.P.
W.C.P.
W.C.P.
5.0in.
14.0in.
3.5in.
0 DEGREES
45 DEGREES
4” BC Aluminized
120V
4.8
1.1
C1
VOLTS AC 60Hz
AMPS - Starting
AMPS - Running
Heater Type:
DESIGN COMPLIES WITH:
ANSI Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.
For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel
Serial No. 0603DETR12345 0001
DETROIT RADIANT PRODUCTS CO.
21400 HOOVER ROAD - WARREN, MI 48089
(586) 756-0950 www.reverberray.com
AG2 - 40 - 125N
MODEL NO.
125,000 / 95,000
INPUT BTU/H
NAT GAS
FOR USE WITH
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
FOR INDOOR INSTALLATION ONLY
DO NOT
AIR
METERING
ORIFICE
REMOVE
NEUTRAL
EARTH
HOT
- 120V HEATER INPUT -
120V
AIR
METERING
ORIFICE
DO NOT
REMOVE
Manifold Pressure
Max. Inlet Pressure
Min. Inlet Pressure for
Purpose of Input Adjustment
Min. Mounting Angle
Max. Mounting Angle
Combustion Chamber
W.C.P.
W.C.P.
W.C.P.
5.0in.
14.0in.
3.5in.
0 DEGREES
45 DEGREES
4” BC Aluminized
120V
4.8
1.1
C1
VOLTS AC 60Hz
AMPS - Starting
AMPS - Running
Heater Type:
DESIGN COMPLIES WITH:
ANS Z83.20b-2003-GAS FIRED LOW INTENSITY INFRA-RED HTR.
For Stainless Steel Upgrades the Combustion Table is upgraded to 409 Stainless Steel
Serial No. 0603DETR12345 0001
DETROIT RADIANT PRODUCTS CO.
21400 HOOVER ROAD - WARREN, MI 48089
(586) 756-0950 www.reverberray.com
AG2 - 40 - 125N
MODEL NO.
125,000 / 95,000
INPUT BTU/H
NAT GAS
FOR USE WITH
RE-VERBER-RAY INFRA-RED RADIANT TUBE HEATER
FOR INDOOR INSTALLATION ONLY
Gas Valve:
Circuit Board:
Wire Harness:
N.O. Switch:
N.O. VL Orifice:
N.C. Switch:
N.C. VL Orifice:
Diff Switch:
Diff VL Orifice:
Igniter:
Burner:
16” Tube:
Ind Lights:
Diag Light:
Term Block:
Transfomer:
Fan:
Alternate Fan:
Alt. Fan Usage:
IS22016051F5169 264E
36E96-224-N
Micro60-24
840
851
3 PCS Harness
852
None
N/A
None
None
N/A
None
Grey (+/-)
Norton
50
High
201
4” Stnd.
202
Yellow - 24V
828
Red LED
827
None
N/A
40VA
826
Fasco Lg.
55A
50Hz - 120V
55B
When Specified
BURNER COMPNENTS (Specify TP - #’s)
Your Heater is: C1
Orifice Type
Gas: TP204-#
Air: TP44-#
C1
C2
C3
3
3
1
1 1/2”
1 5/8”
1 5/8”
Relay:
Filter:
24 Volt In:
120 Volt In:
None
N/A
None
3T - plug
832
2x4 Box
Gas In:
Extra VL Orifice:
7/8” FC Flare
83
None
N/A
66
TUBE COMBINATION / KIT PARTS
Combustion:
Radiant:
Clamp:
Hangers:
RCS:
Reflector:
Endcap:
Baffle:
ID:
Electric:
Special 1:
Special 2:
Tag:
For Internal Use Only
TP-26A
TP-26A
TP-21B
TP-19B
TP-82
TP-20C
TP-105
TP-651 - 4”R
TP-26E
TP-26D
TP-21O
TP-19B-SS
TP-82-SS
TP-20C-SS
TP-105-SS
Item
Standard
Stainless Steel
Re-Verber-Ray
LLWT38
Micro60
Plug-Wh.
None
For all
Standard
Labels
See Board
Contact factory at 586-756-0950 for parts information and list prices. Or visit
http://wwwreverberray.com/parts
Data on this label is for the model shown on this label. If your heater has been
converted, this information is not correct. Please contact the factory for assistance.
RVA2-40-125N
Production Code: RVA2-125
Version: 8/06
0603DETR12345 0001
Serial #:
N/A
Stock:
None
Add-On Option(s):
SAMPLE
SAMPLE
Safety Labels and Their Locations
1.0 Safety • Safety Labels and Locations
Read and understand all safety information and warnings in this insert manual and the
Tube Heater General Manual before installation, operation and maintenance of the
radiant tube heater system.
Back Panel
Top Panel
AG2 Series
Rating Plate
F/N: LLTB018 (Natural Gas)
F/N: LLTB019 (LP Gas)
F/N: LLTB008
F/N: LLTCL001 Clearance to
Combustibles Label
3
Burner Control Box
Component Label (located
under the top panel)
Product safety signs or labels should be replaced by the product user when they no longer are legible.
Contact either your local distributor or the product manufacturer for obtaining replacement signs or labels.
24V
24V IN
NEUTRAL
- 24V HEATER INPUT -
F/N: LLV3EP8
NEUTRAL
EARTH
HOT
- 120V HEATER INPUT -
120V
F/N: LLV3EP1
LED CODE
FAULT STATUS
FAULT CODE DELAY
Initial flash on power up,
then steady off
Normal operation
Immediate
Steady on
Module failure / Internal fault
Immediate
1 flash
Ignition failure
30-32 minutes
2 or 3 flashes
APS - Note: fan / intake / exhaust
10-12 minutes
4 flashes
Solenoid valve fault / Leaky valve /
Flame amplifier fault
Immediate
No flash on 117V start up
Transformer fault
Immediate
! CAUTION
Provide 24
Volts Only
This heater has a 24 Volt
control system. Do not
connect 120 Volt power
supply, as it will damage
the controls.
LED CODE
FAULT STATUS
FAULT CODE DELAY
Initial flash on power up,
then steady off
Normal operation
Immediate
Steady on
Module failure / Internal fault
Immediate
1 flash
Ignition failure
30-32 minutes
2 or 3 flashes
APS - Note: fan / intake / exhaust
10-12 minutes
4 flashes
Solenoid valve fault / Leaky valve /
Flame amplifier fault
Immediate
No flash on 117V start up
Transformer fault
Immediate
This heater is equipped with an
HLRB (Relay Board) required for
grouping multiple heaters on the
same thermostat. This heater must be wired
with a field supplied transformer in accordance
with the installation, operation manual.
AVOID EQUIPMENT FAILURE
THIS 10 FT. TUBE IS THE
COMBUSTION CHAMBER.
THIS TUBE MUST BE THE FIRST TUBE
FOLLOWING THE BURNER CONTROL BOX.
!
INSTALLER
The combustion chamber utilizes either 409
stainless, titanium alloy or aluminized steel -
depending on the model number of your heater.
Rotate the tube’s welded seam to bottom.
Consult the manual(s) for further details.
4
1.0 Safety • Safety Labels and Locations • Clearance to Combustibles
F/N: LLTP031 (This label is located on
models with a relay board installed only.)
AG2 Series
F/N: LLTB007(2)
F/N: LLDR003
(This label is
located on models
with a relay board
installed only).
SERVICE ACCESS PANEL
IGNITER & FLAME SENSE COMPARTMENT
1. Turn off gas & electricity.
2. Remove cover by lifting top
cover upward and outward.
CAUTION: HOT SURFACE.
KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
SERVICE ACCESS PANEL
IGNITER & FLAME SENSE COMPARTMENT
1. Turn off gas & electricity.
2. Remove cover by lifting top
cover upward and outward.
CAUTION: HOT SURFACE.
KEEP COVER IN PLACE. REMOVE FOR SERVICE ONLY.
INSTALLER
***AVOID EQUIPMENT FAILURE***
THIS 10’ TUBE IS THE
COMBUSTION CHAMBER.
THE COMUSTION CHAMBER UTILIZES
EITHER 409 STAINLESS TITANIUM OR ALUMINIZED
STEEL - DEPENDING UPON THE
MODEL NUMBER OF YOUR HEATER
THIS TUBE MUST BE THE FIRST TUBE
FOLLOWING THE BURNER BOX.
MOUNT WELDED SEAM TO BOTTOM
CONSULT IOM OR PACKAGING STICKER FOR DETAILS
F/N: LLTB004 (orange)
F/N: LLTB026
Right Panel
(Valve Compartment)
Radiant
Tube
Primary Combustion
Chamber
16” Burner Tube
Left Panel
(Fan Compartment)
! CAUTION
Provide 24
Volts Only
This heater has a 24 Volt
control system. Do not
connect 120 Volt power
supply, as it will damage
the controls.
F/N: LL01 - Clearance Safety Tag
(Affix adjacent to heater’s thermostat)
HIGH
FIRE
H
L
LOW
FIRE
F/N: LLV2EP9