This appliance complies with European Safety Standard EN 60335-2-40, EN 60335-1,and EN 62233.and European Electromagnetic
Capability(EMC) EN 55014-1,EN 55014-2,EN 61000-3-2 and EN 61000-3-3.These cover the essential requirements of EEC Directives
2006/95/EC and 2004/108/EC.
8/51273/0 – Issue 3
SAFETY INFORMATION
1.
Please read the operating instructions carefully before using your
dehumidifier for the first time and keep them in a safe place.
2.
Never immerse the appliance in water or other liquids.
3.
Never operate the appliance if a cable or connector has been damaged,
after appliance malfunction or if the appliance was dropped or
otherwise damaged.
4.
Please ask a professional service agent to repair the product. Improper
repair may cause danger to users.
5.
Never allow children to operate the appliance.
6.
Disconnect the appliance from mains power whenever it is not in use,
before relocating it, and before cleaning.
7.
Operate the appliance only at the voltage specified on the rating label.
8.
This appliance is designed for household purposes (not commercial) only.
9.
DO NOT COVER. Never cover or obstruct in any way the outlet at the
top of the dehumidifier or the air inlet slots at the rear of the dehumidifier.
10. To prevent spillage, empty the water tank before relocating the appliance.
11. Do not tip the appliance to any side as escaping water could damage the
appliance. Only operate the product in a level upright position.
12. This appliance can be used by children aged from 8 years and above
and persons with reduced physical,sensory or mental capabilities
or lack of experience and knowledge if they have been given supervision
or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning
and user maintenance shall not be made by children without supervision.
Installation and Operating Instructions
Model:
10L
Dehumidifier
Model:
DXDH10IR
Dehumidifier
16L
DXDH16BK
2
3
13. When the supply cord is damaged, it must be replaced by the
manufacturer, or a professional service agent only.
14. Please keep the product from the wall or overhanging objects
e.g. curtains at minimum 50cm distance.
15. Unplug the appliance before cleaning.
16. When the unit stops, you have to wait for 3 minutes before you can
restart the unit to protect the compressor from damage
OPERATING INSTRUCTION
1. Control panel
2. Air outlet
3. Handel
4. Front housing
5. Air Inlet / Back housing
6. Drain hole
7. Water tank
CONTROL PANEL DESCRIPTION
OPERATING INSTRUCTION
STARTING THE UNIT
1.
Firstly, turn the humidity control switch to the “OFF” position.
2.
Plug in the dehumidifier.
3.
Turn on the humidity control switch (clockwise) and turn the same
switch to the reading of the desired humidity (60% in general as shown
on position“4”).
TURNING OFF THE UNIT
1.
Turn the humidity control switch fully anticlockwise to the “OFF”
position and the power supply is cut off and the unit stops operating.
2.
If the dehumidifier is not in use for a long time, please disconnect the
power cord plug from the supply outlet.
NOTES AND PRECAUTIONS
1. The dehumidifier will not operate if the humidity setting is higher than the
ambient humidity.
2. When the water tank is full an automatic float switch shuts down the product
and the tank full LED illuminates. Remove the water storage tank and empty
its contents, carefully replace the empty water tank back in position, the unit
will now automatically restart operating.
3. The following table indicates the approximate relative humidity settings
against its related position number on the humidity control switch:
4.
The operational temperature range for this unit is 5-32℃.
CONTROL SWITCH
POSITION NO.
APPROXIMATE
HUMIDITY SETTING
Cont.
Continuous
running
8
20﹪
7
30﹪
6
40﹪
4
60﹪
2
80﹪
4
5
5.
Other than on the case of note 2 above, where the dehumidifier does not
start, the operational light does not illuminate or the dehumidifier
intermittently stops for unknown reasons, please check the plug and power
supply for poor connection. If the plug and power supply are in good
condition, wait for 10 minutes and restart the unit (it can take about 10
minutes for the unit to reset). If the unit still does not start after 10 minutes,
please contact your retailer or the manufacturer for repair.
6. When the dehumidifier is in operation, the running compressor will
produce heat. This is normal and may potentially raise the room
temperature.
7.
When the product is defrosting, related indicating light will illuminate.
DRAINAGE INSTRUCTION
Switch off before carrying out any of these operations and leave for 3 minutes
before switching on again. The extracted water is collected by the water tank
(set up as supplied), or can be set up to drain continuously using a PVC hose
(not included) connected to a water outlet tube , the drain point must be lower
than the unit outlet (see details below).
USE OF WATER TANK:
When the tank full LED illuminates the tank is full, the
compressor and the fan will stop operation, please
empty the water tank. Remove the water tank:
Remove the water tank as per Fig 01 and empty it.
Gently refit the water tank into the unit in its original
position.
CONTINUOUS DRAINAGE
If you want to use this function, please pull out the water tank and plug a 9mm
internal diameter water pipe onto the “Water out
tube” (See Fig.02).Replace the water tank into the
unit, the unit will now operate while discharging the
extracted water through the free end of the fitted
pipe, Note, please ensure the free end is below the
outlet connection.
Please ensure drain away is lower than the unit
outlet.
Filter Removal
To remove the filter you must first remove
the water tank as instructed above.
The filter can then be removed from its slot
by gripping the filter handle and sliding it
down and out of the back of the appliance
as indicated below.
Every 2 weeks, remove the filter and clean
it with warm water, below 40°C. Allow it to
dry naturally and then replace by reversing
the removal instruction above
Care and Maintenance Instruction
1.
To avoid the occurrence of vibration and noise the unit should not be
operated while located on any soft or uneven surface.
2.
Never insert any foreign objects into the unit through its air inlet or outlet to
avoid hazard or unit failure.
3. During power off or when not in use for a long time, please disconnect the
product from the mains.
4. For a better dehumidifying effect, the areas in the front and rear of the
unit should be clear and free from any obstacles which will block the air
flow of the unit. Do not block any air inlet or outlet grilles – keep clear of
hanging drapes, curtains and furnishings- DO NOT COVER.
Fig 01
Fig 02
Pages Preview: