DMP Electronics 865 Manuals

1 pdf manual(s) DMP Electronics 865 for free download (Document Types: Installation manual)

DMP Electronics 865 Installation manual [PDF] (2 pages)

  • Identifier: id-1780654
  • Brand: DMP Electronics
  • Device: 865 Control Unit
  • Type: PDF
  • Key Aspects: Glossary of Technical Terms, Warranty and Service Information, Routine Functionality Testing
  • UPD Date: 29.06.2026
  • Source File: 1759620.pdf
  • Pages: 2
  • Description: Device setup manual for the DMP Electronics 865.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
865 STYLE W/X NOTIFICATION MODULE Installation Guide DESCRIPTION 5 6 7 8 9 10 11 4 3 2 1 AUX PWR TRBL BELL SILENCE BELL POWER GROUNDED AT PANEL NORMAL MODEL 865 GND FAULT GND ALARM INPUT BELL PWR + INPUT BELL PWR - INPUT BELL A+ OUTPUT BELL A- OUTPUT BELL B+ OUTPUT BELL B- OUTPUT BELL TRBL BELL TRBL The 865 NAC module provides Style W or X supervision for ground faults, opens, and shorts on notification appliance circuits connected to fire alarm control panels. The 865 is suitable for use with 2 or 4-wire circuits. The module also includes a Trouble LED, Ground Fault LED, and a set of Normally Closed Trouble contacts to indicate off normal conditions. Additionally, the module includes a Bell Silence switch for use during testing or service. Connect a maximum 5 Amp, 12 or 24 VDC regulated, power limited power supply listed for Fire Protective Signals to the module to support alarm power requirements beyond the panel alarm output capacity. Compatibility • XT30/XT50 Series panels • XR150/XR550 Series panels What is Included? • One 865 NAC Module • One Model 308 10k Ohm Resistor with Leads • Hardware Pack 1 MOUNT THE MODULE The module can be mounted in a DMP enclosure using the standard 3‑hole mounting pattern. Refer to Figure 2 as needed during installation. 1. Hold the plastic standoffs against the inside of the enclosure side wall. 2. Insert the included Phillips head screws from the outside of the enclosure into the standoffs. Tighten the screws. 3. Carefully snap the module onto the standoffs. WIRE THE MODULE 2 Caution: Disconnect all power from the panel before wiring the module. Failure to do so may result in equipment damage or personal injury. For power connections, use 22 AWG or larger wire. Refer to Figure 3 and Figure 4 when wiring the module. 1. Connect module Terminal 1 to panel Terminal 7. 2. Connect module Terminal 2 to panel Terminal 10. 3. Connect module Terminal 3 to panel Terminal 5. 4. Wire power supply positive to module Terminal 4. 5. Wire power supply negative to module Terminal 5. 6. If powering the NACs from the control panel, connect a jumper between module Terminals 3 and 4 and between Terminals 2 and 5. For supervised circuits, ground fault is detected at 0 (zero) Ohms. 7. For Style W connections, wire module Terminals 6-11 as shown in Figure 3. Install the included 10k Ohm EOL resistor across Bell Output A + and Bell Output A –. 8. For Style X connections, wire module Terminals 6-11 as shown in Figure 4. Trouble contacts are connected to a zone on the panel to indicate NAC trouble or ground faults. The common relay is rated 30 VDC @ 1 Amp, resistive. 9. For Style W and Style X circuits, install a jumper on the Bell Ground Header. The jumper also disables the alarm bell output in the event of a ground fault on either side of the notification circuit. Figure 1: 865 Module Figure 2: Standoff and Module Installation BACK 1 2 3

865: Related Instructions

1102
DMP Electronics 1102 Installation manual
29.06.2026 5 pages

INSTALLATION GUIDE 1102 Wireless Universal Transmitter Product manual for the DMP Electronics 1102 Transmitter. This guide offers instructions on operating instructions, energy usage, component replacement.

XT Series
DMP Electronics XT Series Installation & quick start manual
20.08.2026 4 pages

XT SERIES WIRELESS INSTALLATION QUICK START GUIDE LT-1289 20171 © 2020 Digital Monitoring Products, Inc. 2. INSTALL THE ENCLOSURE Select a Location Choose a lo Service and user manual for the DMP Electronics XT Series Control Panel. This manual provides information on maintenance schedule, startup procedures, service instructions.

EBOX-3100-VGA
DMP Electronics EBOX-3100-VGA Operation & user’s manual
02.09.2026 33 pages

EBOX-3100-VGA User Manual DMP Electronics Inc. EBOX-3100-VGA User’s Guide Installation and maintenance guide for the DMP Electronics EBOX-3100-VGA Server. The manual covers procedures for daily usage, calibration steps, setup, support details.

XR150FC Series
DMP Electronics XR150FC Series Operation & user’s manual
11.04.2026 40 pages

Product reference manual for the DMP Electronics XR150FC Series Measuring Instruments. The manual provides technical details on setup validation, testing procedures, installation steps.

9800 Series
DMP Electronics 9800 Series Installation and programming manual
14.06.2026 48 pages

INSTALLATION AND PROGRAMMING GUIDE 9800 Series Graphic Touchscreen Keypad System Armed TODAY WEDNESDAY 82 98 77 CURRENT HI LO 85 68 HI LO 98 Complete user documentation for the DMP Electronics 9800 Series Keypad. It covers maintenance schedule, user instructions, maintenance procedures.

1114
DMP Electronics 1114 Installation manual
14.07.2026 4 pages

Product instruction manual for the DMP Electronics 1114 Extender. The documentation includes details on user instructions, device safety checks, security instructions, operation.

Similar Manuals in the Control Unit Category

625 Series
HWH 625 Series Operator's manual
16.05.2026 17 pages

OPERATOR’S MANUAL ML38929/MP05.6032 10AUG06 Touch Panel Leveling Control BI-AXIS Hydraulic Leveling FEATURING: HWH CORPORATION (On I-80, Exit 267 South) 2096 Comprehensive setup guide for the HWH 625 Series Control Unit. This manual describes setup, usage, and maintenance guidelines, user preferences, performance details.

Staufix
Kessel Staufix Instructions for installation, operation and maintenance
23.08.2026 72 pages

ANLEITUNG FÜR EINBAU, BETRIEB UND WARTUNG Rückstauverschluss Staufix zum Einbau in eine freileigende Wasserleitung Stand 2019/07 Sach-Nr. 016-052 Installat Setup and usage guide for the Kessel Staufix Control Unit. It describes maintenance tasks and internal layout, setup instructions, troubleshooting guides, diagnostic information.

Relion 670 series
ABB Relion 670 series Applications manual
05.09.2026 944 pages

RELION® 670 SERIES — Line distance protection REL670 Version 2.2 ANSI Application manual User documentation for the ABB Relion 670 series Protection Device. This guide explains the features and device features, cleaning instructions, system checks, menu navigation.

VEOX SP 3 BODY
Definox VEOX SP 3 BODY Maintenance notice
27.08.2026 37 pages

MAINTENANCE NOTICE NM-277 index 02 Page 1/37 June 2020 MIXPROOF VALVE VEOX SP 3 BODY www.defi User setup guide for the Definox VEOX SP 3 BODY Control Unit. The document covers operation, power management, product maintenance, diagnostic information.