DOLD VARIMETER RCM Manuals

2 pdf manual(s) DOLD VARIMETER RCM for free download (Document Types: Installation / monitoring technique, Installations)

Available Documents for VARIMETER RCM:

DOLD VARIMETER RCM Installation / monitoring technique Main Page Preview

Installation / monitoring technique [PDF] (8 pages)

  • Brand: DOLD
  • Model: VARIMETER RCM
  • Format: PDF
  • Key Aspects: Performance Optimization Tips, Safety Recommendations and Warnings, Initial Startup Checklist
  • Updated: 31.05.2026
  • Source File: 1868550.pdf
  • Pages: 8
  • Description: Operational manual for the DOLD VARIMETER RCM.

Document Preview & Text Transcription

1 15.01.20 en / 177A Your advantages • Preventive fire and system protection • Increasing the availability of plants by early fault detection • As option with external or internal residual current transformer • Protection against manipulation by sealable transparent cover over setting switches Features • According to IEC/EN 62020 • for AC and pulsating DC currants Type A to IEC/TR 60755 • 9 tripping values from 10 mA to 10 A or from 10 mA ... 30 A • Frequency range 20 ... 2000 Hz • Selection of manual or automatic reset • With prewarning • With test and reset button • Broken wire detection • Short reaction time • With adjustable delay tv • De-energized on trip • LED indication for auxiliary supply and state of contact • 2 x 1 changeover contact • Devices available in 3 enclosure versions: IL 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 880 - width 35 mm - for connection of external residual current transformer, e. g. ND 5016, ND 5019 or split current transformer ND 5014 SL 5882: 100 mm deep with terminals near to the top to be mounted in cabinets with mounting plate and cable ducts - width 35 mm - for connection of external residual current transformer, e. g. ND 5016, ND 5019 or split current transformer ND 5014 IR 5882: 63 mm deep with terminals near to the bottom to be mounted in consumer units or industrial distribution systems according to DIN 43 88 - width 105 mm - with internal residual current transformer 0239971 Detection of insulation faults in grounded voltage systems. The residual current relay is used to maintain electrical plants before faults occur. Decrease in insulation can be detected and indicated early without inter- ruption of operation. Installation / Monitoring Technique VARIMETER RCM Residual Current Monitor IL 5882, SL 5882, IR 5882 Approvals and Markings Application Function Diagram M8368_a A1/A2 t Alarm Prewarning i Alarm Prewarning 11-12 21-22 Test Reset manual reset with link X1/X2 with manual reset 11-14 21-24 11-14 tv tv tv manual reset manual reset tv A025518 IR 5882 with internal residual current transf. ND 5016/024 IL 5882 ND 5016/035 ND 5016/070 Split current transf. ND 5014/050 Split current transf. ND 5014/080 Split current transf. ND 5014/120 All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 2 15.01.20 en / 177A LED "ON" LED "Prewarning" LED "Alarm" setting of alarm value time delay for alarm and prewarning Reset button Test button M8369_b green LED "ON": on, when supply connected red LEDs "VW", "AL": on, when insulation failure (prewarning and alarm) If time is set to 0 and a pulsating fault current is flowing (e.g. 1-way rec- tified) the output relay may flicker because of the short reaction time. By increasing the time delay this effect can be avoided. M8349_a X1 14 A1 24 i 12 22 X2 11 A2 21 k A1 X1 i k A2 X2 11 21 12 22 14 24 AL VW A1 X1 PE A2 X2 4 11 21 12 22 14 24 L1/L2/L3/N M11134 24 14 22 12 21 11 A1 A2 X1 X2 AL VW IR 5882 IL /SL 5882 The function of the IL/SL 5882 and IR 5882 can be compared to a fault current circuit braker unit. It detects and indicates residual currents, but does not disconnect. The measurement is done by an external residual current transformer e. g. ND 5016 which is connected via terminals i and k to the IL/SL 5882. At the device IR 5882 the residual current transformer is integrated. All conductors of the voltage system to be monitored are run through the CT except the ground wire. In a fault free voltage system the sum of all current is 0 and the CT induces no secondary voltage. If due to an insulation fault a fault current flows to ground, the current difference in the CT creates a measuring current, which is detected and measured by the IL/SL 5882 or IR 5882. A broken wire in the sensing circuit would disable the measurement, therefore a special circuit detects broken wire and forces the unit to trip. The unit has 2 x 1 changeover contacts. Contact 11-12-14 for alarm (AL) and 21-22-24 for prewarning (VW). Prewarning is detected at 70 % of the selected alarm value. With external bridge X1-X2 the alarm is stored and has to be reset by pressing the reset button or by disconnecting the auxiliary supply. Without bridge X1-X2 the unit works with auto-reset and the fault is not stored. With the button "Test" a fault can be simulated (Alarm). Each contact is delayed with an adjustable time delay tv (same delay time for alarm and pre-warning). To avoid unauthorised adjustment of the potentiometers the unit has a transparent cover that could be seald with laquer. Two holes above the push buttons allow activation of test and reset. Function Connection terminals Terminal designation Signal description A1, A2 Auxiliary voltage i, k (only at IL/SL 5882) Conn. f. external current transformer ND5016, ND5019 ; terminals i, k X1, X2 control input X1/X2 bridged: with manual reset of alarm X1/X2 not bridged: without manual reset of alarm (Hysteresis function) 11, 12, 14 1. C/O contact (Alarm) 21, 22, 24 1. C/O contact (Pre-warning) Circuit Diagrams Setting Note Indication 3 15.01.20 en / 177A Vibration resistance: Amplitude 0.35 mm frequency 10 ... 55 Hz IEC/EN 60068-2-6 Climate resistance: 20 / 060 / 03 IEC/EN 60068-1 Terminal designation: EN 50005 Wire connection: 2 x 2.5 mm2 solid or 2 x 1.5 mm2 stranded wire with sleeve DIN 46228-1/-2/-3/-4 Wire fixing: Flat terminals with self-lifting clamping piece IEC/EN 60999-1 Fixing torque: 0.8 Nm Mounting: DIN rail IEC/EN 60715 Weight IL 5882: approx. 125 g SL 5882: approx. 150 g IR 5882: approx. 300 g Dimensions Width x height x depth: IL 5882: 35 x 90 x 63 mm SL 5882: 35 x 90 x 100 mm IR 5882: 105 x 90 x 63 mm (inner diameter current transformer: 21.5 mm or 28 mm) Input Auxiliary voltage UH: AC/DC 12 V, AC/DC 24 ... 230 V Voltage range: AC: 0.8 ... 1.1 UN DC: 0.9 ... 1.25 UN Nominal frequency UH: 50 ... 400 Hz Nominal consumption AC 230 V: 4 VA AC 24 V: 1.6 VA DC 24 V: 1 W Measuring value adjustable via rotational switch: AC 0.01; 0.03 A; 0.1 A; 0.3 A; 0.6 A 1 A; 2 A; 5 A; 10 A or AC 0.01 A, 0.03 A; 0.1 A; 0.3 A; 0.6 A 1 A; 2 A; 7 A; 30 A Frequency range: 20 Hz ... 2 kHz at failure current < 50 Hz and the function "auto reset", a time delay must be adjusted, so that the relay does not buzz before switching Hysteresis: approx. 4% of trip value, fixed Accuracy: ≤ 0 ... -30 % Repeat accuracy: ≤ ± 1 % Temperature drift: ≤ ± 0.05 % / K Reaction time: 10 ... 40 ms Response delay tv: 0 ... 5 s adjustable (logarithmic scale in order to allow also short time delay to be adjusted without problems) Output Contacts: IL / SL / IR 5882.38: 1 changeover contact for Prewarning, 1 changeover contact for Alarm Thermal current Ith: 5 A Switching capacity to AC 15: NO contact: 3 A / AC 230 V IEC/EN 60947-5-1 NC contact: 1 A / AC 230 V IEC/EN 60947-5-1 to DC 13: NO contact: 2 A / DC 24 V IEC/EN 60947-5-1 NC contact: 1 A / DC 24 V IEC/EN 60947-5-1 Electrical life to AC 15 at 1 A, AC 230 V: 3 x 105 switching cycles EN 60947-5-1 Short circuit strength max. fuse rating: 4 A gG / gL EN 60947-5-1 Mechanical life: ≥ 108 switching cycles General Data Operating mode: Continuous Temperature range Operation: - 20 ... + 60°C Storage: - 25 ... + 70°C Altitude: < 2000 m Clearance and creepage distances rated impulse voltage / pollution degree supply / contacts: 4 kV / 2 IEC 60664-1 supply / Measuring Circuit: corresponding to CT EMC Surge voltages: class 3 (5 kV / 0.5 J) DIN VDE0435-303 HF-interference: class 3 (2.5 kV) DIN VDE0435-303 Electrostatic discharge: 8 kV (air) IEC/EN 61 000-4-2 HF irradiation IEC/EN 61000-4-3, EN 50121-3-2 80 MHz ... 1 GHz: 20 V / m 1 GHz ... 2,7 GHz: 10 V / m Fast transients: 4 kV (class 4) IEC/EN 61000-4-4 Surge voltages: 1 kV (class 3) IEC/EN 61000-4-5 HF wire guided: 10 V IEC/EN 61000-4-6 Interference suppression: Limit value class B EN 55011 Degree of protection: Housing: IP 40 IEC/EN 60529 Terminals: IP 20 IEC/EN 60529 Housing: Thermoplastic with V0-behaviour according UL subject 94 IL 5882.38 AC/DC 24 ... 230 V 50 / 60 Hz 10 A 5 s Article number: 0055138 • De-energized on trip • Auxiliary voltage UH: AC/DC 24 ... 230 V • Measuring range: 10 A • Response delay tv: 5 s • Width: 35 mm SL 5882.38 AC/DC 24 ... 230 V 50 / 60 Hz 10 A 5 s Article number: 0055515 • De-energized on trip • Auxiliary voltage UH: AC/DC 24 ... 230 V • Measuring range: 10 A • Response delay tv: 5 s • Width: 35 mm IR 5882.38 AC/DC 24 ... 230 V 50 / 60 Hz 10 A 5 s Article number: 0066743 • Internal residual current transformer (Ø 28 mm) • De-energized on trip • Auxiliary voltage UH: AC/DC 24 ... 230 V • Measuring range: 10 A • Response delay tv: 5 s • Width: 105 mm ND 5016/024 Article number: 0066009 • Residual current transformer for IL/SL 5882 • Diameter: 24 mm • DIN-rail mounting: waagrecht oder senkrecht • Screw mounting: M4 IL 5882.12/002: with 2 changeover contacts for alarm and no pre-warning Ordering example for variant IL 5882 .38 /_ _ _ AC/DC 24 ... 230 V 50/60 Hz 10 A 5 s Response delay Measuring range Frequency range Auxiliary voltage Variant, if required Contacts Type Technical Data Technical Data Standard Types Variant 4 15.01.20 en / 177A Ambient temperature ND 5016: - 20 ... + 60°C / 253 K ... 333 K ND 5019: - 10 ... + 50°C / 263 K ... 323 K Inflammability class: V0 according to UL94 Nominal insulation voltage acc. to IEC 60 664-1: AC 630 V Rated impulse voltage / pollution degree: 6 kV/3 Voltage test acc. to IEC/EN 60 255: AC 3 kV Transformation ratio: 500 /1 Length of connection wires Type of wire: Single wire: up to 1 m Single wire Twisted pair: up to 10 m Screened wire; screen on terminal k: up to 25 m Wire cross section ND 5016: 0.2 ... 1.5 mm2 ND 5019: 0.75 mm2 Stripping length: 8 mm Wire fixing ND 5016: Terminals with spring connection and direct (Push in) technology ND 5019: Box terminals Screw connection: ND 5016: M3 or M4 ND 5019: M5 Fixing torque: 0.8 Nm DIN rail mounting: ND 5016/024, /035: integrated clips for vertical and horizontal mounting ND 5016/070: integrated clips for horizontal mounting ND 5019: using mounting adapter ET 5018 for DIN rail mounting or screw mounting Residual Current Transformer ND 5016/024, ND 5016/035 ND 5016/024 øD L L1 B H C E F k Dimension/mm 24 82 75 24 54 25 42* 46 4,2 Weight / g approx. 80 Article number 0066009 ND 5016/035 øD L L1 B H C E F k Dimension/mm 35 88 81 24 67 25 42* 46 4,2 Weight / g approx. 90 Article number 0067064 *) Drill tolerance for screw mounting: ± 0.5 mm for DIN rail mounting or screw mounting ND 5016/070 øD L H H1 B C F k E G Dimension/mm 70 111 110 115 32 37 55 4,2 50* 74* Weight / g approx. 220 Article number 0067065 *) Drill tolerance for screw mounting: ± 0.5 mm Residual Current Transformer ND 5016/070 Accessories Technical Data Residual Current Transformer ND 5016, ND 5019 High forces when mounting may damage the current transformer fixtures. The fixing clips are designed to support the current transformer. Forces that are applied by the cable running through the current transformer can only be tolerated within limitations. During installation and afterwards please make sure that the wires are led through the current transformer without applying pressure and remain stable in that position. Mounting instructions for screw mounting M10979_b B E F k D H L1 L C B E F k D H H1 L C C G M11582_a
DOLD VARIMETER RCM Installations Main Page Preview

Installations [PDF] (8 pages)

  • Brand: DOLD
  • Model: VARIMETER RCM
  • Format: PDF
  • Key Aspects: Common Issue Diagnostic Flows, Emergency Shutdown Procedures, FAQ Section for Common Queries
  • Updated: 12.04.2026
  • Source File: 1760467.pdf
  • Pages: 8
  • Description: User instructions for the DOLD VARIMETER RCM.

Document Preview & Text Transcription

1 04.03.20 en / 201A 0272374 Your Advantage • Preventive fire and system protection • Increasing the availability of plants by early fault detection • Universal usage at AC/DC mains • Protection against manipulation by sealable transparent cover over setting switches Features • According to IEC/EN 62020, VDE 0663 • For AC and DC systems Type B • To detect earth faults in grounded voltage systems • 4 setting ranges from 10 mA to 3 A • Manual reset, with alarm and pre-warning • With adjustable switching delay • Energized or de-energized on trip • LED indicator for operation, pre-alarm and alarm • With test function • LED-chain indicates fault current • As option with analogue output • Broken wire detection • Width: 52.5 mm The residual current monitor type B is designed to monitor DC systems and AC systems up to 250 Hz. green LED „ON“: On, when auxiliary supply connected yellow LED „Pre-Alarm“: Flashes during time delay tv On, when pre-alarm active red LED „Alarm“: Flashes during time delay tv On, when alarm active yellow and red LED: Flashes on broken wire or extremely high input signal yellow LED-chain: LED chain indicates fault current in % of adjusted alarm value 1) RN 5883 Variant /61; 2) ND 5015 The devices measure AC and DC current (AC / DC sensitive. Due to the measurement principle they also detect magnetic fields in the next to the current transformer. When planning a panel with AC/DC sensitive residual current monitors please make sure that no components are placed next to the CT that create a magnetic field, e.g. contactors, transformers etc. If an influence is detected, also a rotation of the CT by 90° could positively reduce the influence. The AC/DC sensitive residual current monitor RN 5883 allows an early detection of insulation faults and detects differential currents with AC as well as DC components in grounded voltage systems (type B). The measurement takes place via an external current transformer. Contrary to an RCD the residual current monitor RN 5883 does not dis- connect the mains when detecting a fault but only indicates it. Besides the easy to read LED chain indicating the actual current several LEDs display operation, pre-alarm and alarm. The 4 measuring ranges cover 10 to 3 A. Additional features are broken wire detection, test function and adjustable pre-alarm. The residual current monitor RN 5883 provides early information for precise and cost effective maintenance before the plant stops. RN 5883 M11213 11 14 A1 k1 k2 12 21 22 24 U+ U- A2 i1 i2 X1 X2 A1 X1 i1 i2 k1 k2 A2 X2 11 21 12 22 14 24 Alarm Pre - Alarm IF 0...10V U+ U- Installations- / Monitoring Technique VARIMETER RCM Residual Current Monitor, Type B for AC and DC Systems RN 5883 Approvals and Markings Product Description Circuit Diagram Application Indication Notes Connection Terminals Terminal designation Signal description A1, A2 Auxiliary voltage UH i1, k1, i2, k2 Connection of an external residual current transformer X1, X2 Parameterization input energized or de-energized on trip 11, 12, 14 Contacts alarm signal 21, 22, 24 Contacts pre-alarm signal U-, U+ Analogue output (option) ND 5015/035 ND 5015/070 Canada / USA 1) A025518 Canada / USA 2) All Technical Data in this list relate to the state at the moment of edition. We reserve the rigth for technical improvements and changes at any time. 2 04.03.20 en / 201A The Measuring circuit includes an external residual current transformer. All conductors of a voltage system are fed through the transformer except the ground wire. In a healthy system the sum of all flowing currents is zero, so that no voltage is induced in the CT. If an earth fault occurs, sourcing a current flowing to ground, the current difference induces a current in the CT that is detected by the RN 5883. If an earth fault occurs, sourcing a current flowing to ground, the current difference induces a current in the CT that is detected by the RP 5883. On broken sensor wires and broken CT coils the unit goes into alarm state and the LEDs for pre-alarm (yellow) and alarm (red) flashes. The unit has 2 changeover output contacts. One for alarm 11, 12, 14 and 21, 22, 24 and one for pre-alarm. 4 Setting Ranges can be slected from 10 mA to 3 A. The fine adjustment is made via potentiometer „Factor“ Measuring range = Range x Factor. The alarm relay switches at 100 % of the adjusted response value. The pre-alarm can be set in 10% steps between 10 and 100% of the alarm value. Potentiometer tv sets the switching delay between 0 and 10 seconds. The delay reacts on pre-alarm and alarm. The different CT sizes require a correct adaption of the residual current monitor. 3 models are available: Type Suitable residual current transformer Frequeny range RN 5883.12/61 ND 5015/024 ND 5015/035 DC + AC up to 250 Hz RN 5883.12/010/61 ND 5015/070 DC + AC up to 180 Hz RN 5883.12/020 ND 5018/105 ND 5018/140 ND 5018/210 DC + AC up to 60 Hz Table 1 An external link on X1-X2 allows the change between energized and de- energized on trip. A change of the function will only be valid after interrup- tion of the supply voltage. Terminal X1 / X2: external link = De-energized on trip, open = Energized on trip De-energized on trip: In the case of groundfault or missing auxiliary supply the relays are de-energized, the NC contacts 11/12; 21/22 are closed In fault free state the relays are energized, the NO contacts 11/14; 21/24 are closed Energized on trip: In the case of groundfault the relays are energized, the NO contacts 11/14; 21/24 are closed in fault free state the relays are de-energized, the NC contacts 11/12; 21/22 are closed If an adjusted value is reached on the measuring input (alarm or pre- warning)at the standard type RN 5883 the signal is stored. Reset is made by pressing the button „Test/Reset“ for < 3 s s or by disconnecting the auxiliary supply (approx. 30 s). If the „Test/Reset“ button is pressed for > 3 s, a test of the unit is made. The time delays run, the pre-warning and alarm is activated. An LED chain shows the fault current between 10 and 100 % of the adju- sted alarm value. An analogue output 0 ... 10 V indicates also the fault current. 10 V corre- sponds to 100 % of the adjusted alarm value. It is of advantage to keep the range small and the Factor high. Example: Setting 300 mA: Range 0,1 x Factor 3 = 300 mA Set-up and Adjustment Facilities Function M11736 LED "ON" U connected H LED „Pre-Alarm“ LED "Alarm" LED chain I = e.g. pA IA x setting in % : I = 60mA x 50% = 30mA Pre-alarm relay trips at 30mA LED chain shows at that moment 50% pA Pushbutton <3s = reset fault memory >3s = devise test I : Pre-Alarm pA I : Alarm value = Range x Factor A e.g.: I = 0,01A x 6 = 60mA A I = Alarm relay trips at 60mA LED chain shows at that moment 100% A t : response delay reacts on Alarm and Pre-Alarm v RN 5883.12/001 3 04.03.20 en / 201A Input Auxiliary voltage UH: AC/DC 24 ... 80 V, AC/DC 80 ... 230 V Voltage range at UH = AC/DC 24 ... 80 V: DC 19 ... 110 V, AC 19 ... 90 V, at UH = AC/DC 80 ... 230 V: DC 64 ... 300 V, AC 64 ... 265 V Nominal frequency UH: AC 50 / 60 Hz Nominal consumption at AC: 5 VA at DC: 2.5 W Measuring range: 10 ... 100 mA, 30 ... 300 mA, 100 ... 1000 mA, 300 ... 3000 mA (3 ... 30 mA on request) Measuring range fine adjustment: 1 ... 10 Überlastbarkeit: with overload protection Alarm: 100 % of the adjusted measuring range Pre-alarm: 10, 20, 30, 40, 50, 60, 70, 80, 90, 100 % of the adjusted alarm value Frequency range: DC and AC to 250 Hz*) *) depending on the differential current transformer used. See „Function“ Table 1. Repeat accuracy: ≤ ± 3 % Temperature drift: ≤ ± 0.1 % / K Reaction time: 300 ms Switching delay Pre-alarm / alarm: 0 ... 10 s Output Contacts: 1 changeover contact for pre-alarm, 1 changeover contact for alarm Thermal current Ith up to 30 °C: 5 A up to 40 °C: 4 A up to 60 °C: 2 A Switching capacity at AC 15: NO contact: 3 A / AC 230 V IEC/EN 60947-5-1 NC contact: 1 A / AC 230 V IEC/EN 60947-5-1 Electrical life to AC 15 at 1 A, AC 230 V: 3 x 105 switch. cycl. IEC/EN 60947-5-1 Short circuit strength max. fuse rating: 4 A gG / gL IEC/EN 60947-5-1 Mechanical life: ≥ 108 switching cycles Analogue Output (option) Terminal U+ / U-: 0 ... 10 V; 5 mA variant RN 5883/_ _1 Screened wire; screen one end grounded at device to PE General Data Operating mode: Continuous Temperature range Operation: - 40 ... + 60°C - 20 ... + 60°C (variant /_1_ and /_2_) Storage: - 40 ... + 70°C Altitude: < 2000 m Insulation coordination according to IEC 60664-1: RN 5883 cennected with current transformer ND 5015, ND 5018 Rated impuls voltage / pollution degree: Auxiliary voltage / Meas. circuit: 6 kV / 2 Auxiliary voltage / Contacts: 6 kV / 2 Auxiliary voltage / Analoge output: 6 kV / 2 Contacts / Analoge output: 6 kV / 2 Meas. circuit / Analoge output: 6 kV / 2 Contacts 11,12,14 / 21, 22, 24: 4 kV / 2 EMC Surge voltages: Class 3 (5 kV / 0.5 J) DIN VDE 0435-303 Electrostatic discharge: 8 kV (air) IEC/EN 61000-4-2 HF irradiation 80 MHz ... 2,7 GHz: 20 V / m (class 3) IEC/EN 61000-4-3 HF-wire guided: 10 V (class 3) IEC/EN 61000-4-6 Fast transients: 2 kV (class 3) IEC/EN 61000-4-4 Surge voltages: 1 kV class 3) IEC/EN 61000-4-5 Interference suppression: Limit value class B EN 55011 Degree of protection Housing: IP 30 IEC/EN 60529 Terminals: IP 20 IEC/EN 60529 Housing: Thermoplastic with V0-behaviour according UL subject 94 Vibration resistance: Amplitude 0.35 mm frequency 10 ... 55 Hz IEC/EN 60068-2-6 Climate resistance: 40 / 60 / 03 IEC/EN 60068-1 Terminal designation: EN 50005 Wire connection: DIN 46228-1/-2/-3/-4 Fixed screw terminals Cross section: 0.5 ... 4 mm² (AWG 20 - 10) solid or 0.5 ... 4 mm² (AWG 20 - 10) stranded wire without ferrules 0.5 ... 2.5 mm² (AWG 20 - 10) stranded wire with ferrules Stripping length: 6.5 mm Wire fixing: Cross-head screw / M3 box terminals Fixing torque: 0.5 Nm Mounting: DIN rail IEC/EN 60715 Weight: approx. 160 g Dimensions Width x height x depth: 52.5 x 90 x 71 mm These devices only monitor residual currents and are not intended to be used as Ground Fault Circuit Interrupter (GFCI) in accordance with UL1053 / UL943. These devices have been investigated to be used with external differen- tial current transformers manufactured by E. Dold & Söhne KG, Cat. Nos. ND5015/024/61, ND5015/035/61 or ND5015/070/61. Supply voltage UN: AC/DC 24-80V single or double phase 50/60 Hz; AC/DC 80-230V single or double phase 50/60 Hz Switching capacity relays Ambient temperature 30°C: 5A, 250Vac G.P. 250 Vac, 2A pilot duty 250 Vac, 1/2hp Ambient temperature 40°C: 4A, 250Vac G.P. 250 Vac, 2A pilot duty 250 Vac, 1/2hp Ambient temperature 60°C: 2A, 250Vac G.P. Analogue output (only at variant/__1): 0 .. 10V, 5mA Max. measuring frequency: DC, AC (0 – 250Hz) Wire connection: AWG 20 - 12 60°C / 75°C copper conductors only nfo Technical data that is not stated in the UL-Data, can be found in the technical data section. Technical Data Technical Data UL-Data RN 5883