Dormakaba 5750-K Manuals
2 pdf manual(s) Dormakaba 5750-K for free download (Document Types: Installation manuals, User operating instructions)
Dormakaba 5750-K Installation manuals [PDF] (9 pages)
- Identifier: id-1517517
- Brand: Dormakaba
- Device: Dormakaba 5750-K Locks
- Type: Installation manuals, PDF
- Key Aspects: Environmental Factors and Restrictions, Best Practices for Everyday Use, Routine Functionality Testing
- UPD Date: 24.05.2026
- Source File: 1480912.pdf
- Pages: 9
- Description: Professional manual for the Dormakaba 5750-K.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Installation Guide Electronic Entry Device LA GARD Basic & Gard Series Document Number 762.128 Rev. G — 05 / 2018
Dormakaba 5750-K User operating instructions [PDF] (2 pages)
- Identifier: id-1852343
- Brand: Dormakaba
- Device: Dormakaba 5750-K Intercom System
- Type: User operating instructions, PDF
- Key Aspects: Technical Support and Resource Links, Recommended Spare Parts List, Glossary of Technical Terms
- UPD Date: 09.08.2026
- Source File: 1870419.pdf
- Pages: 2
- Description: Device guide for the Dormakaba 5750-K.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
(P/N) 7032.0316 Rev A 02/17 • © copyright 2017 Kaba Mas LLC Page 1 of 2 USER OPERATING INSTRUCTIONS OPENING THE LOCK 1. Enter valid combination (insert eKEY, if set up, then remove key). 2. The lock will confirm a valid combination entry with a double signal. 3. Within four (4) seconds, turn the keypad to the open position (clock-wise) if using a deadbolt style lock, or turn the handle to the open position if using a swingbolt style lock. 4. Pull door open. • Invalid Combination Entry - Lock will signal three (3) times. IMPORTANT NOTE: Change the combination before putting the lock into operation. IMPORTANT NOTE: Keep eKEY and combinations secure and separated from each other to minimize opportunity of compromise and/or security breach. WRONG TRY PENALTY • Entry of four (4) consecutive invalid combinations starts a five (5) minute delay period. - LED flashes red at ten (10) second intervals. • At the end of the delay period, two (2) more consecutive invalid combinations will restart the five (5) minute delay period. During delay period, any keystroke will give three audio and visual signals. CHANGING YOUR COMBINATION IMPORTANT NOTE: When using eKEY in initialization and combination change, this must be performed by an authorized person in a secure environment. 1. Enter existing combination and hold down last digit until unit double signals and LED stays on. Observe that the unit will double signal indicating a correct combination is entered, and then, as the last digit is held down, it will double signal 2-4 seconds later and the LED will remain on indicating the unit is now ready to receive change commands. If eKEY is enabled, the eKEY behaves as if it were the last digit in a combination. So, if eKEY is enabled, enter existing combination and insert eKEY. The unit will double signal indicating a correct combination + eKEY is entered, and then, as the eKEY remains inserted, the unit will double signal 2-4 seconds later and the LED will remain on indicating the unit is now ready to receive change commands. Then REMOVE eKEY to proceed.] WARNING: The port for the eKEY is a data port only. Connecting power to this port will damage the system. IMPORTANT NOTE: Never use this electronic token in applications other than this HSL Model. FEATURES See Manager Instructions for additional features. USER COMBINATION • Open Lock • Change Combination KEYPAD BACKLIGHTING • Press either lightbulb icon to illuminate panel keys EKEY AND AUDITING CAPABILITY • eKEY is a 48 bit encrypted unique serialized dual token device • AuditGard auditing software, AuditView or LGView, and a LA GARD interface Adapter are required. WRONG TRY PENALTY • Four (4) consecutive invalid combination initiates five (5) minute delay period. LOW BATTERY WARNING • Repeated LED flashing and beeping during opening indicates battery is low and needs immediate replacement. AUDIO AND VISUAL SIGNAL • Double signal - two (2) LED flashes and two (2) beeps - indicates entry is valid or accepted. • Triple signal - three (3) LED flashes and three (3) beeps - indicates invalid or not accepted. Keypads models 5715, 5750,5750-K are compatible with 4200 (solenoid) and 4200M (motor), 3800/3801/3802/3803 Firmware, 4300 (solenoid) and 4300M (motor), 3800/3801/3802/3803 Firmware, 6040 (solenoid) and 6040M (motor) High Security electronic locks. The eKEYII function is not verified by UL. LA GARD 5750-K ELECTRONIC ENTRY DEVICE
Similar Manuals in the Intercom System, Locks Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Farfisa ALBA FP51SAB |
#E9S26H: ALBA FP51SAB Intercom System Manual |
24 | 1122 | 180 | 24-03-2026 | view all manuals | |
Centurion POLOphone |
Intercom System #73LS55 |
16 | 1118 | 213 | 18-06-2026 | view all manuals | |
Vimar ELVOX 6200 |
#24718C: ELVOX 6200 Intercom System Installation instructions |
2 | 1196 | 228 | 14-03-2026 | view all manuals | |
Blueant Interphone none |
Interphone none Datasheet - 3HOQLD |
2 | 1.07 Mb | 684 | 130 | 26-03-2026 | view all manuals |
Chamberlain Icon26 series |
PDF Guide (@NY2V74), Chamberlain Icon26 series Intercom System (29-05-2026) |
44 | 846 | 204 | 29-05-2026 | view all manuals | |
golmar Rock Series |
golmar Rock Series User Manual (Installation manual), @62V7B4 |
60 | 1017 | 224 | 26-04-2026 | view all manuals |