Dräger X-zone 5000 Manuals

3 pdf manual(s) Dräger X-zone 5000 for free download (Document Types: User manual manual, Supplement)

Dräger X-zone 5000 User	manual	manual Main Page Preview

Dräger X-zone 5000 User manual manual [PDF] (26 pages)

  • Brand: Dräger
  • Model: X-zone 5000
  • Format: PDF
  • Updated: 08.08.2026

Document Preview & Text Transcription

de Gebrauchsanweisung �2 en Instructions for Use � fr Notice d’utilisation � es Instrucciones de uso � it Istruzioni per l'uso � nl Gebruiksaanwijzing � da Brugsanvisning � no Bruksanvisning � Dräger X-zone 5000 03333112.eps DRAFT 02 - 08/02/10
Dräger X-zone 5000 User	manual	manual Main Page Preview

Dräger X-zone 5000 User manual manual [PDF] (196 pages)

  • Brand: Dräger
  • Model: X-zone 5000
  • Format: PDF
  • Updated: 13.03.2026

Document Preview & Text Transcription

de Gebrauchsanweisung � 2 en Instructions for Use � 26 fr Notice d’utilisation � 50 es Instrucciones de uso � 74 it Istruzioni per l'uso � 98 nl Gebruiksaanwijzing � 122 da Brugsanvisning � 146 no Bruksanvisning � 170 Dräger X-zone 5000 03333112.eps
Dräger X-zone 5000 Supplement Main Page Preview

Dräger X-zone 5000 Supplement [PDF] (4 pages)

  • Brand: Dräger
  • Model: X-zone 5000
  • Format: PDF
  • Updated: 07.06.2026

Document Preview & Text Transcription

1 Supplement Dräger X-zone 5000 Multiple unit communication was not tested according "CSA C22.2 No. 152 - Combustible Gas Detection Instruments" and is therefore not covered. Calibration procedure X-zone 5000 (pump mode) Carrying out the fresh air calibration Calibrate the X-am 5000 to fresh air, free of measured gases or other interfering gases. During the fresh air calibration the zero point of all sensors (with the exception of the DrägerSensors XXS O2 and XXS CO2) is set to 0. For the DrägerSensor XXS O2 the display is set to 20.9 vol.-% and for the DrägerSensor XXS CO2 to 0.0 vol. %. � Switch on the X-am 5000. � Press the [ + ] key 3 times, the symbol for fresh air calibration » « appears. � Press the [ OK ] key to start the fresh air calibration function. – The measured values flash. When the measured values have stabilized: � Press the [ OK ] key to perform the calibration. � The display containing the current gas concentration changes with the display » OK «. � Press the [ OK ] key to exit the calibration function or wait for approx. 5 seconds. If a fault has occurred during the fresh air calibration: – The fault message » « appears and » « is displayed for the respective sensor instead of the measured value. � In this case, repeat the fresh air calibration. If necessary, have the sensor replaced by qualified personnel. Carrying out 1-button calibration – All the sensors which can be calibrated are included in the 1-button calibration. – In the case of the 1-button calibration, the sensitivity of all sensors is set to the value of the test gas. When using the test gas cylinder containing mixed gas with 50 ppm CO, 15 ppm H2S, 2.5 vol. % CH4, 18 vol. % O2. � Connect the test gas cylinder to an on-demand valve. � Insert the X-am 5000 into the X-zone 5000 and switch it on. � Press the [ + ] key and hold it depressed for 5 seconds to open the calibration menu. � Enter the password (password on delivery = 001). � Use the [ + ] key to select the 1-button calibration function. – The symbol for 1-button calibration » « flashes. � Press the [ OK ] key to start the 1-button calibration. � Connect the hose of test gas cylinder on-demand valve to the X-zone 5000. � Vent the test gas into a fume cupboard or to the open air. – The currently displayed measured values start to flash. The flashing stops after a static measured value has been reached. – The calibration is carried out automatically. – The displayed measured values change to the values according to the gas supplied. When the calibration is completed and the displayed measured values have stabilized: – The display indicating the current gas concentration changes and displays » OK «. � Press the [ OK ] key or wait 5 seconds to quit the calibration. – The X-am 5000 switches into the measuring mode. � Disconnect the hose of the test gas cylinder on- demand valve from the X-zone 5000. If a fault occurred during the 1-button calibration: – The fault message » X « appears and » - - « is displayed for the respective sensor instead of the measured value. � In this case, repeat the calibration. � If necessary, replace the sensor. enUS NOTICE Supplementary information regarding CSA approved operation. NOTICE For calibration intervals see the Instructions for Use/ data sheets of the sensors used. NOTICE If a mixed gas with another composition is used, the specified concentration values in the X-am 5000 must be changed to the target values of the mixed gas used using the PC software Dräger CC Vision.