DSC pg9945 Manuals
1 pdf manual(s) DSC pg9945 for free download (Document Types: Installation instructions)
DSC pg9945 Installation instructions [PDF] (4 pages)
- Identifier: id-1571220
- Brand: DSC
- Device: pg9945 Security Sensors
- Type: PDF
- Key Aspects: Glossary of Technical Terms, Best Practices for Everyday Use, Routine Functionality Testing
- UPD Date: 09.08.2026
- Source File: 1430054.pdf
- Pages: 4
- Description: Device setup manual for the DSC pg9945.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
PG9945_PG8945_PG4945 PowerG 2-way Wireless Magnetic Contact Device with Hard-wired Input Installation Instructions Operation The PGx945 Series is a supervised, 2-way wireless PowerG magnetic contact device. The device includes a built-in reed switch and a separate N.O., N.C. or E.O.L programmable auxiliary hard- wired input for use with other hardwired sensors (use only UL/ ULC fire/burglary listed sensors). The reed switch and the auxiliary input behave as separate transmitters, although they trigger the same RF transmitter. Removing the cover activates the tamper switch. If configured, LED lights only when reporting alarm or tamper events. Built-in link quality indicators reduce installation time by eliminating the need for the installer to physically approach the control panel. Low-Battery Detection The PGx945 includes low-battery condition detection. When this condition is detected a trouble message is transmitted to the compatible receiver/control panel. This will provide visual identification of the unit that requires a battery change. For UL commercial burglary installations replace battery yearly. Device Setup WARNING! To comply with FCC and IC RF exposure compliance requirements, the magnet contact device should be located at a distance of at least 20 cm from all persons during normal operation. The antennas used for this product must not be co-located or operated in conjunction with any other antenna or transmitter. CAUTION! This product uses Lithium Batteries. Improper handling of lithium batteries may result in HEAT GENERATION, EXPLOSION or FIRE, which may lead to personal injuries. WARNING! Danger of explosion if batteries are installed incorrectly. replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. Keep away from small children: if swallowed promptly see a doctor. Do not try to recharge these batteries. Note: Battery replacement should be done by installer. Note: To ensure the continued operation of all wireless devices after performing a system default, a global upload of all wireless programming via DLS is recommended before defaulting the system. After completing the system default, download the wireless programming. Legend A. Flexible Retainer B. Break-away base segment (for back tamper) C. PCB edge supports D. Mounting holes E. Wiring inlet F. LED G. Terminal block for sensor H. Enroll button I. Tamper switch J. Reed switch on underside of PC Board (in unit) K. Symbol on side of the case indi- cates location of reed switch L. Magnet M. 1/4" space maximum (6mm) N. 47 kΩ resistor O. N.C. switch P. N.O. switch Install the battery 1. Insert a flat-edged screwdriver into the slot and push upward to remove cover. 2. Remove the screw and separate the cover from the base. 3. Observe polarity and install battery. 4. Connect the sensor wire to the terminal block. Note: When manually programming wireless devices, if a device has been powered up for more than 48 hours it cannot be enrolled into the system until the device has been tampered and restored. When programming the panel using the Quick Enroll procedure follow the steps detailed in Enroll the Device into the System. Note: After restoring a low battery trouble the system may take up to 5 minutes to clear the trouble. Enroll the Device into the System Refer to the PowerSeries Neo Host Installation Manual or iotega Reference Manual for the enrollment procedure. Placement Testing Before permanently mounting any wireless device, temporarily mount the device and perform a Placement test. 1. Tamper the device by removing the cover. 2. Replace the cover to restore the tamper. The device now enters Placement test mode for 15 minutes. 3. Trip the device by opening the door or window and verify the red LED blinks, indicating detection. 4. After 2 seconds the LED blinks 3 times.The following table indicates received signal strength. IMPORTANT! Only GOOD or STRONG signal strengths are acceptable. If you receive a POOR signal from the device, re-locate it and re-test until a GOOD or STRONG signal is received. Note: For UL/ULC installations, only STRONG signal levels are acceptable. After installation verify the product functionality in conjunction with the compatible receivers HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9, PG9920, WS900-19, and WS900-29. Note: For detailed Placement instructions refer to the control panel Reference Guide Gap Separation Mounting the Device It is highly recommended to attach the transmitter to the top of the door/window on the fixed frame and the magnet to the door or window. Ensure that the magnet is located not more than 6 mm (0.25 in.) from the transmitter’s marked side. Note: Once the cover is removed, a tamper message is transmitted to the receiver. Subsequent removal of the battery prevents transmission of tamper restore, leaving the receiver in permanent alert. To avoid, press the tamper switch while removing the battery. Attention! The unit has an optional back tamper switch under the PCB. As long as the PCB is seated firmly within the base, the switch lever will be pressed against a special break-away base segment that is loosely connected to the base. Be sure to fasten the break-away segment to the wall. If the detector unit is forcibly removed from the wall, this segment will break away from the base, causing the tamper switch to open. Note: For UL Residential Fire and Commercial Burglary installations, the use of the back tamper is mandatory. Note: Adhesive tape not to be used for EU Market. Mounting with screws Note: For UL Residential Fire and Commercial Burglary installations, the use of the mounting screws is mandatory. 1. With the cover removed, flex retainer and remove PCB. 2. Mark & drill 2 holes in mounting surface. 3. Fasten base with 2 countersunk screws. 4. Mount the magnet base with 2 supplied screws. 5. Attach the magnet to the magnet base. Mounting with adhesive tape 1. Peel away the release liners from the two strips of double- sided adhesive tape and attach to the device and magnet. 2. Align the device with the magnet according to the location marks and fasten the device and magnet to the mounting sur- face. Auxiliary Input wiring 1. Connect the auxiliary sensor contacts across the auxiliary input terminals. 2. If the auxiliary input is defined as a Normally Closed (N.C.) type, series connected N.C. sensor contacts must be used exclusively. An E.O.L. resistor will not be required. 3. If the auxiliary input of the is defined as a Normally Open (N.O.) type, parallel connected N.O. sensor contacts must be used exclusively. An E.O.L. resistor will not be required. 4. For E.O.L. supervision: Normally Closed (N.C.) sensor con- tacts can be used. A 47 kΩ E.O.L. resistor must be wired at the far end of the zone loop. Note: For UL installations, the device connected to the initiating circuit must be located in the same room as the transmitter. The drawing below illustrates a N.O. and N.C. alarm circuit with E.O.L. resistor. Note: An alarm message is transmitted once the loop is opened or short circuited. Note: For UL/ULC installations connect only UL/ULC listed device to the auxiliary wiring input. Only one device shall be connected to the input of each RF transmitter. UL985 short range RF transmitter application Model PG9945 is also UL985 listed as a short range RF transmitter for use in Residential fire applications in conjunction with UL listed mechanical heat detectors. The transmitter shall be installed using provided screws and the back tamper shall be enabled. The heat detector shall be connected to the wired input of the RF transmitter device in the same room and within 3 ft. The External Input [001][03] shall be set to [Y] and the Zone EOL [002] shall be set to [02] Normally Open. The Supervision [001][04] shall be enabled [Y] and Reed switch[001][02] operation shall be disabled [N]. When enrolling the device in the compatible receiver/control panel combination set the zone definition to type [08] in order to transmit a fire alarm when the external input is activated. An example of compatible initiating devices that could be used in this type of application is the System Sensor UL listed 5600 Series Mechanical Heat Detectors (only models that have self restoring rate of rise sensors). Refer to the compatible devices installation, testing, and maintenance instructions. Test the self-restoring rate of rise models using a hair dryer or heat gun. When testing the ROR element, to prevent the activation of the fixed temperature element, the heat source must not exceed the fixed temperature rating of the detector. Detectors shall be installed as per NFPA72 and/or the local authority having jurisdiction. Note: Ensure the RF transmitter is used in its intended environmental conditions. Configuration The enter the wireless configuration section enter [804][3 digit zone number] Selections Specifications Frequency Band (MHz): CE Listed PG4945: 433MHz; CE/EN listed PG8945: 868MHz; FCC/IC/UL/ULC listed PG9945: 912- 919MHz band Communication Protocol: PowerG Alarm Input: One internal Supervision: Signaling at 4 minute intervals Tamper Alert: Reported when a tamper event occurs Battery type: 3 V Lithium CR-123A type battery GP Battery Life Expectancy: 8 years (for typical use) Battery Supervision: Automatic transmission of battery condition data as part of periodic status report and immediately upon low battery condition detection Temperature range: -10ºC to +55ºC (UL/ULC only verified the range 0ºC-49ºC) Relative Humidity: up to max. 93%RH, non-condensing Dimensions (LxWxD): 81 x 34 x 25 mm (3-3/16 x 1-1/4 x 1 in.) Weight (including battery): 53g (1.9 oz) Auxiliary Input Cable Length: 10m max, AWG22 Auxiliary Input EOL Resistor: 47 KΩ Installed by service persons and for use in indoor non-hazardous locations only. Low Battery trouble level: 2.2V Compatible Receivers This device can be used with DSC panels and receivers that use PowerG technology. UL/ULC Notes The PG9945 has been listed by UL for commercial and residential burglary and residential fire applications and by ULC for commercial and residential burglary applications in accordance with the requirements in the Standards UL 985 (resi fire applications) and UL634 and ULC/ORDC634 for Door and Window Contact. For UL/ULC installations use this device only in conjunction with compatible DSC wireless receivers: HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9, PG9920, WS900-19, and WS900-29. Europe: The PG8945 is certified by Telefication to the following standards: EN50131-2-6, EN50131- 1 GRADE 2, CLASS II, EN50131-6 Type C. Telefication BV has certified only the 868 MHz variant of this product. According to EN 50131-1:2006 and A1:2009, this equipment can be applied in installed systems up to and including Security Grade 2, Environmental Class II. UK: The PG8945 is suitable for use in systems installed to conform to PD6662:2010 at Grade 2 and environmental class 2. BS8243 The Power G peripheral devices have two- way communication functionality, providing additional benefits as described in the technical brochure. This functionality has not been tested to comply with the respective technical requirements and should therefore be considered outside the scope of the product’s certification. SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Tyco Safety Products Canada Ltd declares that the radio equipment type is in compliance with Directive 2014/53/ EU. The full text of the EU declaration of conformity is available at the following internet address: PG8945 - http://dsc.com/pdf/1401040 PG4945 - http://dsc.com/pdf/1401017 European single point of contact: Tyco Safety Products, Voltaweg 20, 6101 XK Echt, Netherlands. FCC COMPLIANCE STATEMENT WARNING! Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in residential installations. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio and television reception. However, there is no guarantee that interference will not occur in a particular installation. If this device does cause such interference, which can be verified by turning the device off and on, the user is encouraged to eliminate the interference by one or more of the following measures: – Re-orient or re-locate the receiving antenna. – Increase the distance between the device and the receiver. – Connect the device to an outlet on a circuit different from the one that supplies power to the receiver. – Consult the dealer or an experienced radio/TV technician. This equipment complies with FCC and IC RF radiation exposure limits set forth for an uncontrolled environment. This device complies with FCC Rules Part 15 and with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference that may be received or that may cause undesired operation. Le present appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation est autorisee aux deux conditions suivantes :(1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit accepter tout brouillage radioelectrique subi, meme si le brouillage est susceptible d'en compromettre le fonctionnement. PG9945_PG8945_PG4945 Instructions d'installation du détecteur de contact magnétique sans fil bidirectionnel PowerG à entrée câblée Fonctionnement Le PGx945 Series est un dispositif à contact magnétique, sans fil, bidirectionnel, supervisé PowerG. Le dispositif contient un commutateur à lames intégré et une entrée câblée auxiliaire programmable N.F., N.O ou E.D.L., à part à utiliser avec d'autres détecteur câblés (utilisez exclusivement des détecteurs anti- intrusion/anti-incendie homologués UL/ULC.). Le commutateur à lames et l'entrée auxiliaire se comporte comme des émetteurs distincts, même s'ils déclenchent un émetteur RF identique. Le retrait du capot active le contact anti-sabotage. S'ils sont configurés, les voyants lumineux s'allument uniquement en cas de signalisation d'alarme ou d'événements de sabotage. Les indicateurs de qualité de liaison intégrés réduisent les temps d'installation en supprimant la nécessité de l'installateur d'être physiquement à proximité de la centrale. Détection de niveau faible de batterie Le PGx945 possède une fonction de détection de niveau faible de batterie. Quand cet état est détecté, un message de problème est transmis à la centrale ou au récepteur compatible. Une signalisation visuelle est ainsi assurée pour l'unité qui a besoin d'un remplacement de la batterie. Pour les installations anti-intrusion commerciales UL, remplacez la batterie tous les ans. Réglage du dispositif AVERTISSEMENT ! Pour la compatibilité avec les exigences d'exposition IC RF et FCC, le dispositif à contact magnétique doit être placé à une distance d'au moins 20 cm des personnes pendant le fonctionnement normal. Les antennes utilisées avec ce produit ne doivent pas être placées ni utilisées en association avec une autre antenne ou un autre émetteur. ATTENTION ! Ce produit utilise des batteries au lithium. La manipulation incorrecte des piles au lithium peut engendrer UNE PRODUCTION DE CHALEUR, UNE EXPLOSION ou UN INCENDIE, qui peuvent provoquer des blessures personnelles. AVERTISSEMENT ! Risque d'explosion si les piles sont mal installées. Remplacez exclusivement par des piles identiques ou de type équivalent comme recommandé par le fabricant. Éliminez les piles usagées selon les instructions de son fabricant. Éloignez les jeunes enfants : si elles sont avalées, consultez rapidement un docteur. N'essayez pas de recharger ces piles. Remarque : Le remplacement des batteries doit être réalisé par un installateur. Remarque : Pour garantir le fonctionnement continu de tous les dispositifs sans fil après avoir réalisé une réinitialisation aux valeurs par défaut, un téléchargement général de toute la programmation sans fil par DLS est recommandé avant de réinitialiser le système. Après avoir complété la réinitialisation aux valeurs par défaut du système, téléchargez la programmation sans fil. Légende A. Collier de retenue flexible B. Segment de la base défonçable (pour le contact anti-sabotage arrière) C. Supports en bordure de la carte du circuit imprimé D. Trous de fixation E. Entrée à câbler F. Voyant G. Bornier du capteur H. Bouton d'attribution I. Contact anti-sabotage J. Commutateur à lames sur le dessous du circuit imprimé (dans l'unité) K. Un symbole sur le côté du boîtier indique l'emplacement du commutateur à lames L. Aimant M. espace minimum de 6 mm (1/4") N. Résistance de 47 kΩ O. Contact N.F. P. Contact N.O. Installer la pile 1. Insérez un tournevis plat dans la fente et poussez vers le haut pour retirer le couvercle. 2. Retirez la vis et détachez le couvercle de la base. 3. Respectez les polarités et installez la pile. 4. Branchez les fils du détecteur au bornier. Remarque : Quand vous programmez manuellement les dispositifs sans fil, si un dispositif a été alimenté pendant plus de 48 heures, il ne peut pas être attribué dans le système tant que le dispositif n'a pas été saboté et rétabli. Remarque: Après la restauration d'un défaut de batterie faible, le système peut prendre jusqu'à 5 minutes pour que la peine. Attribuer le dispositif dans le système Consultez les instructions d'installation PowerSeries Neo Host ou le manuel de référence iotega pour plus informations sur l'attribution. Test de positionnement Avant de fixer de façon permanente un dispositif sans fil quelconque, montez-le temporairement et effectuez un test de positionnement. 1. Sabotez le dispositif en retirant le cache. 2. Remontez le couvercle pour rétablir le contact anti-sabotage. Le dispositif passe en mode de test de positionnement pendant 15 minutes. 3. Déclenchez le dispositif en ouvrant la porte ou la fenêtre et vérifiez que le voyant lumineux rouge clignote ce qui indique la détection. 4. Après 2 secondes, le voyant clignote 3 fois. Le tableau suivant indique la force du signal reçu. IMPORTANT ! Seules les forces de signal FORT ou BON sont acceptables. Si vous recevez un signal FAIBLE du dispositif, déplacez-le et testez-le à nouveau jusqu'à ce qu'un signal BON ou FORT soit reçu. Remarque : Pour les installations UL/ULC, seul un signal FORT est acceptable. Après installation, vérifiez les fonctionnalités de l'appareil en association avec les récepteurs compatibles HSM2HOST9, HS2LCDRF(P)9, HS2ICNRF(P)9, PG9920, WS900-19, et WS900-29. Remarque : Pour des instructions détaillées sur le positionnement, consultez le guide de référence de la centrale. B A C D E LED response Signal Strength Green LED blinks STRONG Orange LED blinks GOOD Red LED blinks POOR No blinks No communication Metallic (Ferrous) Materials Nonmetallic/Metallic (nonferrous) Materials Direction of Movement of the Magnet Approach/ Make Remove/ Break Approach/ Make Remove/ Break Axis Y 10 mm ± 5 mm 15 mm ± 5 mm 14 mm ± 5 mm 15 mm ± 5 mm Axis X 12 mm ± 5 mm 15 mm ± 5 mm 14 mm ± 5 mm 20 mm ± 5 mm Axis Z 10 mm ± 5 mm 10 mm ± 5 mm 24 mm ± 5 mm 25 mm ± 5 mm Recommended maximum gap separation for installation (on speci- fied materials and axes of use) is 6mm (0.24”). } J L K M Z X Y [001][01] Alarm LED - Default [Y] Enables the devices LED to activate when an alarm event occurs. [001][02] Reed Switch - Default [Y] Enables\disables the reed switch. Note: It shall be set to [N] for UL fire applica- tions. [001][03] External Input - Default [N] Enables\disables the exter- nal input. Note: It shall be set to [Y] for UL fire appli- cations. [001][04] Supervision - Default [Y] Enables supervision of the device. Note: It shall be set to [Y] for UL fire applica- tions. Zone EOL - Default [01] Configures auxiliary input as one of the following options: [00] Disabled [01] Single EOL [02] Normally Open. Note: it shall be set for UL fire applications. [03] Normally Closed N O P Frequency Bands Maximum Power 868.0MHz - 868.6 MHz 10mW 868.7MHz - 869.2MHz 10mW 433.22MHz - 434.64MHz 10mW Réponse du voyant Force du signal Le voyant vert clignote FORT Le voyant orange clignote BON Le voyant rouge clignote FAIBLE Aucun clignotement Aucune communication B A C D E F + - H I G F + - H I G D-307428