DSC TL-150 Manuals

1 pdf manual(s) DSC TL-150 for free download (Document Types: Installation instructions)

DSC TL-150 Installation instructions Thumbnail

DSC TL-150 Installation instructions [PDF] (2 pages)

  • Identifier: id-1556057
  • Brand: DSC
  • Device: DSC TL-150 Cell Phone
  • Type: Installation instructions, PDF
  • Key Aspects: Detailed Installation Instructions, Best Practices for Everyday Use, Pre-Deployment Preparation Steps
  • UPD Date: 23.03.2026
  • Source File: 1445218.pdf
  • Pages: 2
  • Description: User documentation for the DSC TL-150.
Pages Preview:
  • DSC TL-150 Installation instructions preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
THESE INSTRUCTIONS MUST BE USED WITH THE ALARM CONTROL PANEL INSTALLATION MANUAL Power Draw: 65 mA Terminal Connections KEYBUS - The 4-wire KEYBUS connection is used by the panel to communicate with the module. Connect the RED, BLK, YEL and GRN terminals to the KEYBUS terminals on a PowerSeries™ panel. RJ45 - Requires an 8-conductor UTP network cable with an RJ-45 connector on the end. This cable is required to plug into an available port on a router or other DHCP serving network. To Connect Module to a Control Panel 1. Connect module to the Keybus (with the panel powered down). 2. Connect an 8-conductor UTP network cable with RJ-45 connector to an available router, switch or hub port with a DHCP server available. 3. Power up the system. NOTE: The TL-150 module automatically enrolls with the security system as PC5400/DVACS module. Administrator's Programming 1. To enter Administrator's Programming: on a computer on the same net- work, launch a web browser and type "tl-150" in the URL entry line. You will be prompted for a user-name and password. The default administrative username is "admin" and the default password is "admin". This password can be changed any time. The default homeowner username is "user" and the default password is "user". 2. From the main page choose the "Config" hyperlink in the top right corner. 3. Enter the IP address of the DRL-IP where this module reports. 4. Enter the new Receiver Port number (if required). 5. Enter the Encryption Key. Enter up to 32 HEX characters, unused characters are zero padded. 6. Enter the customer's account number. 7. Enter the test transmission period (Valid Entries: 0-99). The number you enter is the number of 15 minute increments the device will wait before sending a test transmission. A value of "0" will disable the test transmission. Enabling test transmissions also enables network supervision. See NOTE 3. 8. Administrator password. 9. Reboot the module using the "Reboot Module" link at the bottom of page. Reset of Admin Password If the installer forgets the administrator password, it is possible to default the module’s administrator’s password. Defaulting the password will send a signal to the central station of a password change (SIA - JV40) . This is to inform the cen- tral station of a possible “take-over” attempt. The installer must request the fol- lowing URL to default the password: http://tl-150/8328641 NOTES: 1. Only one TL150 can be enrolled on a local network 2. If any of the DRL-IP Reporting IP, Cypher Key, Account Code fields are changed you must reboot the module using the "Reboot Module" link at the bottom of the page. 3. Enabling test transmissions also enables network supervision. If the network con- nection is down at the time of a test transmission, a General System Supervisory Trouble will be triggered and the panel will go into trouble. The trouble will be restored on the next successful communication with the receiver. Setting this value to zero disables network supervision entirely. 4. Only the following browsers are supported: Internet Explorer, Firefox/Mozilla, and Netscape. LIMITED WARRANTY Digital Security Controls warrants that for a period of twelve months from the date of purchase, the product shall be free of defects in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the control of Digital Security Controls such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out of abuse, alter- ation or improper application of the equipment. The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls. Digital Security Controls neither assumes responsibility, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume for it any other warranty or liability concerning this product. In no event shall Digital Security Controls be liable for any direct, indirect or consequential damages, loss of anticipated profits, loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this product. Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions. They cannot discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area protection. They have multiple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass doors or windows. Any type of tam- pering whether intentional or unintentional such as masking, painting, or spraying of any material on the lenses, mirrors, windows or any other part of the detection system will impair its proper operation. Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the ambient temperature rises near or above body temperature or if there are intentional or unintentional sources of heat in or near the detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting and so on. Important Information: Changes or modifications not expressly approved by Digital Security Controls could void the user’s authority to operate this equipment. Warning: Digital Security Controls recommends that the entire system be completely tested on a regular basis. However, despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this prod- uct to fail to perform as expected. FCC COMPLIANCE STATEMENT CAUTION: Changes or modifications not expressly approved by Digital Security Controls could void your author- ity to use this equipment. This equipment generates and uses radio frequency energy and if not installed and used properly, in strict accordance with the manufacturer’s instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in any residential instal- lation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause int erference to television or radio reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Re-orient the receiving antenna • Relocate the alarm control with respect to the receiver • Move the alarm control away from the receiver • Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits. If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. The user may find the following booklet prepared by the FCC useful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet is available from the U.S. Government Printing Office, Washington D.C. 20402, Stock # 004-000-00345-4. TL-150 Installation Instructions Residential IP Alarm Communicator Name Color Description KEYB Green OFF - Security system is not connected Flashing - Security system detected but device does not have IP address Solid - Normal operation OPER Red OFF - System is not powered Flashing - Normal operation Solid - Hardware fault ACT Red Flashes - Upon Ethernet activity. Incoming packets only LINK Green OFF - No Ethernet link ON - Ethernet link established Red Blk Yel Grn ACT LINK OPER KEYB RJ45 TO PANEL To available port on router or hub ©2005 Digital Security Controls Toronto, Canada • www.dsc.com Tech. Support: 1-800-387-3630 (Canada & U.S.), 905-760-3036 Printed in Canada 29007190R001

Similar Manuals in the Cell Phone Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
LG GT540

Manual: LG GT540 (5AG1U5, Upd.03-03-2026)

226 1030 176 03-03-2026 view all manuals
LG Tribute

#T314HM: Tribute Cell Phone Get started

26 1171 270 21-04-2026 view all manuals
Palm PIXI PLUS

Cell Phone #3U93Q3

60 343 83 16-06-2026 view all manuals
Samsung GT-S5611

GT-S5611 Operation & user’s manual - 4E2D1H

36 302 64 24-04-2026 view all manuals
Drive S300

#6C68Y9: S300 Cell Phone Operation & user’s manual

107 1145 229 16-08-2026 view all manuals
Motorola M3588

Motorola M3588 Manual (Service manual), @2W79WG

46 1135 216 11-07-2026 view all manuals