Dwyer Instruments SAH SMART Air Hood Series Manuals
3 pdf manual(s) Dwyer Instruments SAH SMART Air Hood Series for free download (Document Types: Installation and operating instructions manual, Specifications-installation and operating instructions)
Dwyer Instruments SAH SMART Air Hood Series Installation and operating instructions manual [PDF] (20 pages)
- Identifier: id-1620701
- Brand: Dwyer Instruments
- Device: SAH SMART Air Hood Series Scales
- Type: PDF
- Key Aspects: Information on Regular Maintenance, End-of-Life Handling and Disposal, Operational Mode Explanations
- UPD Date: 07.06.2026
- Source File: 1609622.pdf
- Pages: 20
- Description: Manual for installation and usage of the Dwyer Instruments SAH SMART Air Hood Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Series SAH SMART Air Hood™ Balancing Instrument - PredictAir™ Application Software Specifications - Installation and Operating Instructions Bulletin TE-SAH-SW The SERIES SAH SMART Air Hood™ Balancing Instrument is the most accurate and easy to operate air flow hood on the market. By using the included hood stand and wireless communications to the handheld, a single operator can balance a branch in less time than traditional balancing teams. Besides being lighter than most traditional capture hoods, the ergonomic design makes the Series SAH easy to maneuver, with less physical stress. The rugged polypropylene base hood features patented Quad Flow Design Technology for controlling air flow and minimizing back pressure, which yields superior measurement accuracy. The Wi-Fi direct communication gives reliable communication with a distance of up to 200 yards between the hood and the handheld test instrument. The SMART Air Hood™ Balancing Instrument includes the PredictAir™ Application Software which reduces the number of steps in the air flow balancing process using Predictive Balancing’s Express Balance mode. Predictive Balancing is a method of predicting the optimal flow set point for each register and the order in which they should be adjusted. Please see Bulletin TE-SAH for general installation instructions. TABLE OF CONTENTS Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Connecting to a Wi-Fi Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Setting up a Google Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Updating the PredictAir™ Application Software . . . . . . . . . . . . . . . . . . . . . . . . . 4 Application Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connecting to the Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Importing a Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Meter Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Zeroing the Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Selecting the Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Manual K-Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Logging Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Hood Information Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Volume Airflow Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Temperature Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Humidity Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Barometer Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Overall Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Predictive Balancing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Branches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Branches Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 Add Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Balancing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Final Results Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18 FCC/Industry Canada Notice . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19 1 DWYER INSTRUMENTS, INC. P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057 www.dwyer-inst.com e-mail: [email protected] ®
Dwyer Instruments SAH SMART Air Hood Series Installation and operating instructions manual [PDF] (12 pages)
- Identifier: id-1841764
- Brand: Dwyer Instruments
- Device: SAH SMART Air Hood Series Test Equipment
- Type: PDF
- Key Aspects: Unpacking and Inspection Guidelines, Environmental Factors and Restrictions, Control Panel and Interface Navigation
- UPD Date: 11.07.2026
- Source File: 1880999.pdf
- Pages: 12
- Description: User support guide for the Dwyer Instruments SAH SMART Air Hood Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 Series SAH SMART Air Hood® Balancing Instrument - SMART Air Hood App® Software Specifications - Installation and Operating Instructions Bulletin TE-SAH-SWV2 The Series SAH SMART Air Hood® Balancing Instrument is the most accurate air flow hood on the market. With single-user ability, the ergonomic design is light weight and easy to maneuver, with less physical stress, while speeding up the balancing process and reducing costs. Constructed of a rugged polypropylene material, the Hood features Quad Flow Design Technology for controlling air flow and minimizing back pressure, which yields superior measurement accuracy. Featuring Wi-Fi direct communication, with a range of up to 200 yards between the hood and the handheld test instrument. The SMART Air Hood® Balancing Instrument includes the SMART Air Hood App® Software for air flow balancing. The app uses predictive balancing which is a method of predicting the optimal flow set point for each diffuser while balancing the HVAC system. The handheld application software includes algorithms enabling the SMART Air Hood to achieve best in class accuracy. TABLE OF CONTENTS Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Connecting to a Wi-Fi Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Setting up a Google® Account . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Updating the SMART Air Hood Application Software. . . . . . . . . . . . . . . . . . . . . 3 Application Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Connecting to the Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 Meter Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Zeroing the Hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Selecting the Diffuser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Manual K-Factor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Preferences . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Hood Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Logging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Predictive Balancing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Branches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Branches Menu . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Add Registers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Balancing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 FCC/Industry Canada Notice. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 Warranty/Return . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 DWYER INSTRUMENTS, INC. P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A. Phone: 219/879-8000 Fax: 219/872-9057 www.dwyer-inst.com e-mail: [email protected] ®
Dwyer Instruments SAH SMART Air Hood Series Specifications-installation and operating instructions [PDF] (5 pages)
- Identifier: id-1570651
- Brand: Dwyer Instruments
- Device: SAH SMART Air Hood Series Test Equipment
- Type: PDF
- Key Aspects: Recommended Spare Parts List, Critical Operational Precautions, Hardware Verification Checklists
- UPD Date: 27.05.2026
- Source File: 1430623.pdf
- Pages: 5
- Description: Complete instruction guide for the Dwyer Instruments SAH SMART Air Hood Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
INCLUDED WITH THE SAH SMART AIR HOOD™ 1. Base unit with 2' x 2' (600 mm x 600 mm) opening 2. UHH2 handheld 3. Storage/carrying case 4. 12' (3.66 m) extension pole 5. 3' (0.91 m) extension pole 6. UHH2 pole attachment 7. Pole pins (Pack of 3) 8. Charging cable and block for SMART Air Hood™ 9. Charging cable and block for UHH2 10. 1' x 4' hood with assembly pack The Series SAH SMART Air Hood™is designed to measure air flow from HVAC air ducts and diffusers for balancing. The SAH is lightweight, rugged, and ergonomically designed for easy use and maneuverability. The interface is Wi-Fi direct to the UHH2 handheld and can transmit up to 200 yards (183 m). The unit includes an on/off switch and LEDs to alert when the unit is connected, transmitting, and when the battery is running low in order to avoid recording inaccurate measurements. The SAH SMART Air Hood™ is durable and easily stores in the included travel case. INTRODUCTION Do not use the UHH2/hood unit for liquid or gas mixtures other than air. No responsibility will be taken by Dwyer Instruments, Inc. for any resulting damage to the unit or to the operators if it is used with corrosive or dangerous or explosive gas mixtures. When using the UHH2/hood to check air flow at ceiling diffusers, make certain that you can raise and hold the unit safely during use. This instrument is not classified as flameproof or intrinsically safe; therefore, it must not be used where an explosion hazard may exist. The unit is not authorized for use on life support applications. Note: Observe standard safety procedures when working on ladders and scaffolding. Also, ensure the unit does not become caught in moving machinery or on sharp objects. • If stored under conditions outside normal operating range, allow the unit to stabilize at room conditions before use. • Owing to its size and shape, take care when carrying the assembled unit from place to place. • Avoid people and nearby equipment. • Avoid objects that may damage the capture hood. • Turn the instrument off before storage or transportation and remove the batteries if storing for long periods of time. • Avoid subjecting the capture hood sensing grid to excessive loading during use or assembly. Any air flow other than through the calibrated sensing holes, such as any hair-line cracks, will seriously affect the sensitivity. • A damaged sensing grid must be replaced. It cannot be repaired. • Take care when fitting different sized canvas hoods of the protruding pins at the capture hood. • Do not disassemble the sensing grid from the capture hood. The retaining structure is specifically designed to accommodate loading due to normal operation. • Under low humidity conditions, static electric charges may be encountered. These can be avoided by applying a suitable anti-static solution. Bulletin TE-SAH Series SAH SMART Air Hood™ SPECIFICATIONS VOLUME FLOW Service: Air. Units: CFM, l/s, m3/h. Range: 30 to 2000 CFM. Accuracy for Any Diffuser > 50 CFM: ±3% of reading ±10 CFM. Resolution: 1 CFM TEMPERATURE Units: °F, °C, K. Range: 40 to 140°F (4.4 to 60°C). Accuracy: ±1.8°F (±1°C). Resolution: 0.01°C RELATIVE HUMIDITY Range: 5 to 95%, non-condensing. Accuracy: ±5% of reading (no calibration required) Resolution: 0.04% RH. ABSOLUTE PRESSURE Units: mbar, Pa. Range: 10 to 2000 mbar. Accuracy @ 25°C: ±2% of reading (between 300 and 1100 mbar). Resolution: 0.016 mbar Power Requirements: 3.7 V MH12210 lithium ion battery, included, user replaceable or (4) 1.5 V AA alkaline batteries, not included, user replaceable. Dimensions: 15" x 24" x 24" (381 mm x 610 mm x 610 mm). Weight: 5.5 lb (2.5 kg) Agency Approvals: CE, FCC.