Eagle Tree Systems eLogger V3 Manuals
2 pdf manual(s) Eagle Tree Systems eLogger V3 for free download (Document Types: Instruction manual)
Eagle Tree Systems eLogger V3 Instruction manual [PDF] (11 pages)
- Identifier: id-2009836
- Brand: Eagle Tree Systems
- Device: Eagle Tree Systems eLogger V3 Data Loggers
- Type: Instruction manual, PDF
- Key Aspects: Hardware Setup Instructions, Risk Mitigation and Accident Prevention, Manufacturer Contact and Support Data
- UPD Date: 02.08.2026
- Source File: 2278022.pdf
- Pages: 11
- Description: User guidebook for the Eagle Tree Systems eLogger V3.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Copyright © 2003-2007 Eagle Tree Systems, LLC Instruction Manual for the eLogger V3 Patent Pending Document Version 2.0, Model # MPRV3-CONN-100, MPRV3-LEADS-100, and MPRV3-LEADS-150 Thank you for your purchase! This instruction manual will guide you through the installation and operation of your eLogger. Please read the entire manual carefully before proceeding. If, after you read the manual (including the Troubleshooting sections!) you have further questions or problems, please visit our web support page for additional support options, at http://www.eagletreesystems.com/Support/support.html. Note that the latest version of this manual is available in PDF form from the Support page of our website. Please also fill out the registration form at the end of this manual if you did not purchase your eLogger directly from Eagle Tree Systems, so we can send you important update information. Key Features Here are a few of the features of the eLogger: • Logs pack current to +/- 100 amps (150 amps with MPRV3-LEADS-150) and voltage from about 5 volts to 70 volts • Current is measured with a true Hall Effects Sensor - NOT a resistance shunt like other units on the market! • Great for bench monitoring of battery charging also! • Supports the PowerPanel LCD Display • Accepts optional inexpensive sensors for three Temperatures, RPM (brushless, magnetic or optical), Airspeed, Altitude, GPS, Servo Current, Throttle Movement, and more • Adjustable logging rate (1-10 samples/second) and lossless data compression for long log times • 4 times the logging space of the eLogger V2, and all data is logged to permanent memory, which retains the data even when the power is removed • Software computes Wattage, mAH, etc. for complete e-flight data. • Fully Compatible with Windows 7 (32 and 64 bit), Vista, 98SE, ME, Win2K and XP™ • Weighs about 0.7 oz (20 grams). Versions with Wire Leads weighs slightly more. • Comes with our state of the art Windows virtual playback display and graphing • Powerful Graphing software has advanced charting features, such as amps vs volts • Internet Updatable firmware - as we add new features or (heaven forbid) have a firmware bug, the update is just a download away! No need to ship hardware back and forth. • Full support for English and Metric units Intended Uses The eLogger was designed for use in Unmanned Radio Controlled models. It is intended to be used exclusively in model planes, boats and cars. Using the eLogger for other purposes is not supported. Further, using the eLogger in situations where its use or failure could result in loss of life, bodily injury or property damage is expressly prohibited. Packing List Your package should include the following: eLogger (either with integrated connectors or with wire leads), Custom USB Cable, and CD-ROM. Steps to Follow Installation and use of the eLogger will be quite easy and enjoyable if you follow these few steps: 1. Read through the manual to understand the important warnings, determine what parameters you want to log, etc. 2. Install the eLogger in your model, as described in the eLogger Installation section below. Pay special attention to the polarity and plug-in location of the sensors, since some of the plugs will fit in more than one location!
Eagle Tree Systems eLogger V3 Instruction manual [PDF] (17 pages)
- Identifier: id-1909174
- Brand: Eagle Tree Systems
- Device: Eagle Tree Systems eLogger V3 Data Loggers
- Type: Instruction manual, PDF
- Key Aspects: Basic Configuration Guidelines, Model Variations and Compatibility, Technical Data and Parameters
- UPD Date: 19.06.2026
- Source File: 1813586.pdf
- Pages: 17
- Description: Full technical guide for the Eagle Tree Systems eLogger V3.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Copyright © 2003-2010 Eagle Tree Systems, LLC Instruction Manual for the eLogger V4 Document Version 1.1, Model # MPRV4-CONN-100, MPRV4-LEADS-100, and MPRV4-LEADS-150 Thank you for your purchase! This instruction manual will guide you through the installation and operation of your eLogger. Please read the entire manual carefully before proceeding. If, after you read the manual (including the Troubleshooting sections!) you have further questions or problems, please visit our web support page for additional support options, at http://www.eagletreesystems.com/Support/support.html. Note that the latest version of this manual is available in PDF form from the Support page of our website. Please also fill out the registration form at the end of this manual if you did not purchase your eLogger directly from Eagle Tree Systems, so we can send you important update information. Key Features Here are a few of the features of the eLogger: • Logs pack current to +/- 100 amps (150 amps with MPRV4-LEADS-150) and voltage from about 5 volts to 80 volts • Current is measured with a true Hall Effects Sensor - NOT a power robbing resistance shunt • Adjustable logging rate (from 50 samples per second to one sample every 5 minutes) • 16 times the logging space of the standard eLogger V3, and lossless data compression. Typically logs all available sensors for about four hours, at 10Hz. • All data are logged to permanent memory, which retains the data even when the power is removed • Fully compatible with our OSD Pro expander • Includes Y cable for throttle position logging • Great for bench monitoring of battery charging also! • Supports the PowerPanel LCD Display • Accepts optional inexpensive sensors for three Temperatures, RPM (brushless, magnetic or optical), Airspeed, Altitude, GPS, Servo Current, and more • Software computes Wattage, mAH, etc. for complete e-flight data. • Fully Compatible with Windows 7 (32 and 64 bit), Vista, 98SE, ME, Win2K and XP™ • Weighs about 0.8 oz (22 grams). Versions with Wire Leads may weigh slightly more. • Comes with our state of the art Windows virtual playback display and graphing software • Powerful Graphing software has advanced charting features, such as amps vs. volts • Internet Updatable firmware - as we add new features or (heaven forbid) have a firmware bug, the update is just a download away! No need to ship hardware back and forth. • Full support for English and Metric units. • Software has built in English, German and Chinese languages. Intended Uses The eLogger was designed for use in Unmanned Radio Controlled models. It is intended to be used exclusively in model planes, boats and cars. Using the eLogger for other purposes is not supported. Further, using the eLogger in situations where its use or failure could result in loss of life, bodily injury or property damage is expressly prohibited. Eagle Tree Systems, LLC, is not responsible for your use of this product, or for any damages or injuries you may cause or sustain as a result of its usage.
Similar Manuals in the Data Loggers Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Trivinci Systems Road-Keeper |
#G7OQ5T: Road-Keeper Data Loggers Operation & user’s manual |
25 | 1129 | 204 | 24-05-2026 | view all manuals | |
Velleman DVM171THD |
Velleman DVM171THD User Manual (Operation & user’s manual), @W24WW7 |
27 | 1015 | 254 | 09-05-2026 | view all manuals | |
Thermo Scientific Smart-Vue Pro |
Thermo Scientific Smart-Vue Pro Manual (Operation & user’s manual), @R36O7V |
50 | 927 | 140 | 14-07-2026 | view all manuals | |
Microtronics myDatalogGauge 3G |
Microtronics Data Loggers Operation & user’s manual (File: PDF, 27-04-2026) |
158 | 1489 | 224 | 27-04-2026 | view all manuals | |
TESTO 191 |
#T3KXF5: 191 Data Loggers Instruction manual |
32 | 897 | 216 | 09-05-2026 | view all manuals | |
Extech Instruments CO220 |
User Guide: Extech Instruments CO220 (4D8K57, Upd.18-07-2026) |
15 | 936 | 216 | 18-07-2026 | view all manuals |