Eaton CVX050 Manuals

2 pdf manual(s) Eaton CVX050 for free download (Document Types: Instruction manual)

Document Preview & Text Transcription

Instruction Manual IM01005016E Effective December 2018 Supersedes December 2013 Contents Description Page Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Disclaimer of warranties and limitation of liability . . . . . . . . . . . . . . . . . . . . . . . . 8 CVX050/100 surge protective device installation and operation 2 Instruction Manual IM01005016E Effective December 2018 CVX050/100 surge protective device installation and operation EATON www.eaton.com Introduction This manual describes how to install a CVX050 or CVX100 surge protective device (SPD) in parallel (shunt) across the electrical supply of the following types of electrical systems: • Single-phase • Split-phase • Three-phase wye (star) • Three-phase delta (no neutral) • Direct current (DC) The SPD is designed to be installed on service entrance, branch panels, and/or individual equipment disconnects, and functions to protect sensitive electronic equipment from damaging voltage transients . The connecting wires do not carry supply current . Instead, they carry only short-duration currents that are associated with a transient event . These instructions do not cover all details, variations, or combinations of the equipment, its storage, delivery, installation, checkout, safe operation, or maintenance . If you require further information regarding a particular application or installation that is not covered in this manual, please contact Eaton’s Power Quality Technical Support at 1-800-809-2772 . Safety precautions A licensed/qualified electrician must complete all instructions described in this manual in accordance with the U .S . National Electrical CodeT, state and local codes, or other applicable country codes . All electrical codes supersede these instructions .  WARNING IMPROPER INSTALLATION CAN CAUSE DEATH, INJURY, AND/OR EQUIPMENT DAMAGE. FOLLOW ALL WARNINGS AND CAUTIONS. COMPLETELY READ AND UNDERSTAND THE INFORMATION IN THIS INSTRUCTION MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THIS EQUIPMENT. IMPROPER WIRING COULD CAUSE DEATH, INJURY, AND/OR EQUIPMENT DAMAGE. ONLY LICENSED/QUALIFIED ELECTRICIANS WHO ARE TRAINED IN THE INSTALLATION AND SERVICE OF ELECTRICAL DEVICES ARE TO INSTALL THIS EQUIPMENT. USE APPROPRIATE SAFETY PRECAUTIONS AND EQUIPMENT FOR ARC FLASH PROTECTION. DURING NORMAL OPERATION, HAZARDOUS VOLTAGES ARE PRESENT INSIDE THE SPD. WHEN INSTALLING THE SPD, FOLLOW ALL SAFE WORK PRACTICES TO AVOID ELECTRICAL SHOCK.  CAUTION DO NOT PERFORM A HIGH-POT TEST WITH THE SPD CONNECTED TO THE ELECTRICAL SYSTEM. FAILURE TO DISCONNECT THE SPD DURING A HIGHPOT TEST WILL RESULT IN DAMAGE TO THE SPD. AFTER INSTALLATION, THIS DEVICE IS NOT REPAIRABLE AND CONTAINS NO SERVICEABLE PARTS. IF THE UNIT SHOULD MALFUNCTION OR NEEDS TO BE REPLACED, CONTACT A QUALIFIED ELECTRICIAN OR EATON CARE AT 877-ETN-CARE (877-386-2273). Table 1. Catalog numbering system In this example, Catalog Number CVX050-480Y identifies a CVX model with the following features and ratings: • Surge current rating of 50 kA peak per phase • Three-phase wye wiring configuration • Voltage range of 220/380 through 277/480 Vac Installation Refer to Table 1 and look at the label on the SPD to verify that the SPD’s voltage rating and wiring configuration matches that of the electrical system . Use a voltmeter to measure the system’s line voltage to ensure that the correct model of SPD is being installed . Damage to the SPD may result if it is connected to an electrical system of a higher voltage or different wiring configuration . Mounting The SPD can be mounted directly to the electrical panel or mounted to a wall using the enclosure’s internal mounting holes or optional external mounting feet . IMPORTANT CHOOSE A MOUNTING LOCATION FOR THE SPD THAT PROVIDES THE SHORTEST AND STRAIGHTEST POSSIBLE WIRING (LEAD LENGTH) FROM THE SPD TO THE ELECTRICAL SYSTEM CONNECTIONS. EXCESSIVE LEAD LENGTH AND SHARP BENDS WILL DEGRADE SPD PERFORMANCE. IF THE ELECTRICAL SYSTEM USES AN ISOLATED GROUND, THE SPD MUST BE ISOLATED FROM GROUND USING INSULATED CONDUIT FITTINGS. WHEN USING CONDUIT, AVOID USING 90° ELBOWS AND KEEP THE CONDUIT RUN AS SHORT AND STRAIGHT AS POSSIBLE. a DC models only available in 50 kA. CVX 050 - 480Y Per phase peak surge current (kA) 50 = 50 100 = 100 a Configuration and voltage ranges (Vac) # of Wires 230L = Single-phase—200, 208, 220, 230, 240, 277 480L = Single-phase—480 240S = Split-phase—100/200, 110/220, 120/240, single-phase 120 240H = Three-phase high leg delta—120/240 208Y = Three-phase wye (star)—100/174, 110/190, 120/208, 127/220 480Y = Three-phase wye (star)—220/380, 230/400, 240/415, 277/480 600Y = Three-phase wye (star)—305/525, 347/600 240D = Three-phase delta—200, 208, 220, 230, 240 480D = Three-phase delta—380, 400, 415, 440, 480 600D = Three-phase delta—525, 600 (600D available in 50 kA only) 048DC = Direct current—48 Vdc a 125DC = Direct current—125 Vdc a 2W 2W 3W 2W 4W+G 4W+G 4W+G 4W+G 3W+G 3W+G 3W+G 3 Instruction Manual IM01005016E Effective December 2018 CVX050/100 surge protective device installation and operation EATON www.eaton.com Conduit installation Mount the SPD directly to the electrical panel using a 3/4-inch chase nipple as shown in Figure 1 . When mounting the SPD outdoors, use weatherproof conduit and fittings to maintain the enclosure’s NEMAT 4X rating . See Figure 2 . a Number and type of wires vary with SPD model. Refer to SPD wiring diagrams. 3/4-inch chase nipple Internally threaded conduit fitting Phase, ground, and neutral wires � Drill or punch a 7/8-inch hole in wall of electrical panel CVX050 SURGE PROTECTIVE DEVICE SURGE PROTECTIVE DEVICE SEE WARNING LABEL DANGER HIGH VOLTAGE Suppression Circuit Status 1 LED per phase, normally on - OK CVX050 Figure 1. 3/4-inch chase nipple mounting Avoid sharp bends in conduit and longer than necessary wire lengths. Keep conduit length as short and straight as possible. CVX050 SURGE PROTECTIVE DEVICE SURGE PROTECTIVE DEVICE SEE WARNING LABEL DANGER HIGH VOLTAGE Suppression Circuit Status 1 LED per phase, normally on - OK CVX050 CVX050 SURGE PROTECTIVE DEVICE SURGE PROTECTIVE DEVICE SEE WARNING LABEL DANGER HIGH VOLTAGE Suppression Circuit Status 1 LED per phase, normally on - OK CVX050 Figure 2. Conduit installation Wall mounting Mount the SPD directly on a wall using the SPD’s internal mounting holes as follows: 1. Gain access to the internal mounting holes by first removing the SPD’s four front cover screws, and then removing the front cover . See Figure 3 . 2. Place the SPD against the wall and mark the locations of the four mounting holes . 3. Attach the SPD to the wall using #8 hardware . 4. Reinstall the front cover . #8 hardware (4 places) installer supplied Cover screws (4 places) torque to 6 in-lb Mounting surface Mounting holes under cover (4) 3.39 (86.0) 4.17 (106.0) Figure 3. Wall mounting using internal mounting holes