Operation & user’s manual [PDF] (84 pages)
- Updated: 21.08.2026
Document Preview & Text Transcription
User Guide
Elcometer AVU
Adhesion Verification Unit
www.elcometer.com
R
For the avoidance of doubt, please refer to the original English language version.
Dimensions:
165 x 155 x 105mm (6.5 x 6.1 x 4.1")
Weight:
3kg (6.6lbs)
© Elcometer Limited 2013 - 2017. All rights reserved. No part of this document may be reproduced, transmitted,
transcribed, stored (in a retrieval system or otherwise) or translated into any language, in any form or by any
means (electronic, mechanical, magnetic, optical, manual or otherwise) without the prior written permission of
Elcometer Limited.
CONTENTS
www.elcometer.com
en-1
R
Section
Page
1
Overview
en-2
2
Box Contents
en-2
3
Getting Started
en-3
4
Performing the Test
en-3
5
Assessing the Results
en-5
6
After Test
en-6
7
Dolly Adaptors
en-6
8
Warranty Statement
en-6
9
Technical Specification
en-6
10
Legal Notices & Regulatory Information
en-7
Appendix A:
en-8
Recommended Test Pressures & Acceptable Ranges
1 OVERVIEW
www.elcometer.com
en-2
R
a The Elcometer AVU is supplied with an Elcometer 506 / 510 20mm dolly adaptor fitted. Dolly adaptors for other
adhesion gauges from Elcometer and other manufacturers, are available as optional accessories -
see Section 7 “Dolly Adaptors” on page en-6 for details.
2
3
4
5
6
7
8
1
a
1
Dolly Adaptor
2
LCD Display
3
Softkeys
4
Battery Life Indicator
5
Adhesion Reading
6
‘Max Hold’ Key
7
Units of Measurement (MPA or PSI)
8
On/Off Key
2 BOX CONTENTS
Elcometer Adhesion Verification Unit (AVU)
Elcometer 506 / 510 dolly Adaptor for 20 & 14.2mm Skirt
Carry Case
2 x AA Batteries
Test Certificate
User Guide
3 GETTING STARTED
3.1 SWITCHING ON / OFF
To switch the gauge on, press and hold the “On/Off” ( ) key.
The gauge has an integrated backlight which will timeout after 30
seconds of inactivity.
The unit will switch off automatically after 5 minutes of inactivity.
www.elcometer.com
en-3
R
3 GETTING STARTED (continued)
3.2 SETTING UP THE ELCOMETER AVU
The procedure outlined below must be followed each time the
Elcometer AVU is switched on, prior to testing adhesion gauges.
a
1
Fit the appropriate dolly adaptor -
screwing clockwise to tighten into
position (Figure 1). The reading on
the Elcometer AVU display should be
zero.
Do not overtighten as this will apply
pressure and result in inaccurate readings.
2
Connect an adhesion gauge or
actuator to the dolly adaptor
(Figure 2).
Elcometer 506 / 510 actuator shown.
3
Apply pressure until the reading on the
Elcometer AVU display is between
2 - 3.4 MPa (300 - 500 psi).
4
Leave the gauge pressured for a
minimum of 30 minutes to prepare the
Elcometer AVU for test and allow the
equipment to settle.
Note: The Elcometer AVU should be set up in an
operating environment of between
20°C to 25°C (68°F to 77°F).
4 PERFORMING THE TEST
Figure 1
Figure 2
The Elcometer AVU is designed to provide users with a method of
a
verifying the performance of their pull-off adhesion gauges .
The performance of an adhesion gauge should be verified at a number
of test pressures. Refer to Appendix A on page en-8 for recommended
test pressures for Elcometer pull-off adhesion gauges based on our
certification procedures. For other manufacturers’ gauges, refer to the
manufacturers’ specification.
a The Elcometer AVU is supplied with an Elcometer 506 / 510 20mm dolly adaptor fitted. Dolly adaptors for other
adhesion gauges from Elcometer and other manufacturers, are available as optional accessories -
see Section 7 “Dolly Adaptors” on page en-6 for details.