elero VariEco+ L-868 Manuals

1 pdf manual(s) elero VariEco+ L-868 for free download (Document Types: Operating instructions manual)

Available Documents for VariEco+ L-868:

elero VariEco+ L-868 Operating instructions manual Main Page Preview

Operating instructions manual [PDF] (8 pages)

  • Brand: elero
  • Model: VariEco+ L-868
  • Format: PDF
  • Key Aspects: Emergency Shutdown Procedures, Information on Regular Maintenance, Documentation and Revision History
  • Updated: 29.05.2026
  • Source File: 922587.pdf
  • Pages: 8
  • Description: Manual for safe operation of the elero VariEco+ L-868.

Document Preview & Text Transcription

VariEco+-868 roller shutter/awning drive Remove the motor cable plug Switch off voltage supply. 1. Press locking mechanism on the plug towards the cable using a screwdriver. 2. Pull out the plug. Insert the motor cable plug 3. Switch off voltage supply. Insert plug until locking mechanism engages. Delivery condition 2 Insert plug Remove plug 1 3 Check the following before installation: • Only turn the limit switch ring slightly before and during assembly. (It interferes with the result of the end position adjustment) • The drive is only capable of operation as installed. • Only perform connecting work with the power turned off. • Do not connect motor plug with mains on. • The hanging must be attached to the winding shaft. • Do not drill in the area of the tubular motor! • The profile tube must have sufficient clearance from the motor tube. Warning! Important safety instructions! Observe the following instructions. Risk of injury due to electrocution. The connections to the 230 V mains must be made by authorised specialist personnel. Check the system (roller shutters, awnings) regularly for wear or damage. The regulations of the local energy supply company as well as the regulations for wet and damp rooms according to VDE 0100 must be followed when making the connections. Only use unmodified original elero electrical parts. Keep people away from the system until it is stationary. When working on the system (servicing, cleaning windows etc.), always disconnect it from the mains supply. Device function: • Commissioning the drive with the assembly cable • Quick limit switch adjustment When the drive is shipped from the factory, the quick limit position adjustment is active. Only use this function for the first adjustment. The limit switches do not switch over during the quick limit position adjustment process. Run to the limit positions. Carry out the re-adjustment via the limit switch adjusting screws after deactivation of the quick limit switch adjustment. Further limit position changes are only possible via the limit switch adjusting screw. Intended use • Please ensure that the radio installations are not operated in areas of increased possible interference. (e.g. hospitals, airports ...). • The radio control is only permitted for devices and units with which a functional interference in hand-held/wall-mounted transmitters or receivers poses no danger for persons, animals or materials or where this risk is covered by other safety appliances. • The operator has no protection whatsoever from interferences by other radio emitters and local terminals (e.g. also from radio installations), that are normally used on the same frequency range. • Only use radio receivers with equipment and units approved by the manufacturer. Optimal use of the radio signal • Do not bend the antenna. • Do not shorten or extend the antenna. • If reception is poor, adjust the antenna. • Install the antenna so that it is as exposed as possible. • The minimum distance between two radio drives must be at least 15 cm. Installation Observe the following installation instructions! – The drive must be fixed in such a way that it does not endanger personnel. – Before installing the drive, all lines and equip- ment, which are not required for operation, must be removed from the site. – During installation, during operation and when work is carried out on the system, the opti- on to separate all three poles from the mains must always exist (Hirschmann connector and Hirschmann coupling or a two-pole switch with minimum 3 mm contact gap or all-pole main switch). – If the drive is controlled by a switch with OFF pre-setting (dead man’s button), the momentary contact switch must be fitted at a height of more than 1.50 m and separated from the moving parts. The travel range of the systems must always be visible during operation. – Moving parts in a drive, which are below 2.5 m, must be protected. – Set torque and set operating time must be adapted to the requirements of the product which is driven. – Please note the technical data on the type plate. – Please note that with this drive (type M and L tubular motors) the smallest internal tube diameter corresponds with 46 mm and 56 mm. – The drive must be installed so that it cannot get wet. – Do not install drives in surroundings which are at risk of explosion or in mobile appliances (e.g. motor vehicles). – Keep children away from the (remote) control unit. Warning! Remove of the motor cable plug Risk of injury due to electric shock. When the motor cable plug is removed the supply line must have no voltage. Warning! Keep these instructions in a safe place! After installation of the tubular drive attach these instruc- tions to the cable fot the electrician. → → → 138188206_EN_1112 Mounting and initial operation Explanation of ProLine buttons Hand-held/wall transmitter elero Auto LR03 (AAA) Programming button P (Back of unit) Programming button P Back of wall transmitter 3 2 1 3 2 1 Mains Assembly cable connection (only permissible for commissioning or setting procedures) 1. Commissioning Mains 2. Switch on mains. Radio connection (transmitter operation) 3 2 1 3 2 1 2. Switch on mains. 2 Note: Before you put the drive into the radio mode, you must set the end position. Shaft assembly Installation in profile tubes ① On round tubes, cut a slot in the end of the tubes on the drive side (width 4 mm, length 6 mm)! ② Push the drive (do not knock in) so that the drive lug engages in the slot. ③ Screw on or rivet on the coupling (adaptor)! ④ Attach the hangings to the shaft! Run in the DOWN direction if it is necessary to install the hangings on the winding shaft. Secure the abutment against axial shifting by riveting or bolting the cross member. 1 4 2 3 UP button STOP button DOWN button UP button STOP button DOWN button Blue (neutral wire) (1) Black (2) Brown (3) Green-yellow Blue (neutral wire) (1) Black (2) Brown (3) Green-yellow Mounting and initial operation 3 Note: The maximum limit switch range is 35 revolutions of the shaft. Use the adjusting tool for carrying out the adjustment. Delivery status/factory setting - + - + Quick limit switch adjustment position „On“ The quick limit switch adjustment is activated at the factory. Releasing screw is in the „On“ position. The arrow of the releasing screw points in the direc- tion of the crown adaptor. Limit switches are not active in the quick limit switch adjustment. Adjusting tool Adjusting tool 13 116.3801 Note: The limit switches will only work after the motor has been installed in the shaft. Quick limit switch adjustment 1. Attach the hangings to the shaft. Run in the DOWN direction if it is necessary to move the winding shaft. 2. Use the motor cable to move the hangings in the UP direction until you reach the desired limit position. 3. Turn the releasing screw to the „Off“ position. The arrow of the releasing screw points in the direction of the cable. Use an adjusting tool to do so. 4. Both limit positions are now roughly pre-set. The fine adjustment must be carried out using the individual adjusting screws. Only at commissioning - + - + Quick limit switch adjustment position ”Off“ 4 Adjustment of the end positions Checking the end positions Allow the drive to run alternately in both directions until the limit switch switches off. - + - + Limit switch adjustment screws 1. Allow the drive to run fully in the „Down“ direction. 2. Attach the roller shutter to the shaft. 3. Press the UP button on the assembly cable and keep it depressed. Setting of the upper end position (Fine adjustment or end position changes) Setting the lower end position (Fine adjustment or end position changes) 4. Turn the adjusting tool of the UP limit switch adjustment screw in the + or – direction until the end position is reached. One turn of the limit switch adjustment screw represents approx. 60° of turning of the winding shaft. Limit switch adjustment screws 1. Press the DOWN button on the assembly cable and keep it depressed. - + - + 2. Turn the adjusting tool of the DOWN limit switch adjustment screw in the + or – direction until the final end position is reached. One turn of the limit switch adjustment screw represents approx. 60° of turning of the winding shaft. The directional arrows show the corresponding travel direction of the limit switch screws (4 mm Allen screws). minus (–) = shorter travel plus (+) = longer travel Directional arrow Adjusting tool Adjusting tool Directional arrow