VariEco+-868 roller shutter/awning drive
Remove the motor cable plug
Switch off voltage supply.
1. Press locking mechanism on the plug towards the cable using a
screwdriver.
2. Pull out the plug.
Insert the motor cable plug
3. Switch off voltage supply. Insert plug until locking mechanism
engages.
Delivery condition
2
Insert plug
Remove plug
1
3
Check the following before installation:
• Only turn the limit switch ring slightly before and during
assembly. (It interferes with the result of the end position
adjustment)
• The drive is only capable of operation as installed.
• Only perform connecting work with the power turned off.
• Do not connect motor plug with mains on.
• The hanging must be attached to the winding shaft.
• Do not drill in the area of the tubular motor!
• The profile tube must have sufficient clearance from the motor
tube.
Warning!
Important safety instructions!
Observe the following instructions.
Risk of injury due to electrocution.
The connections to the 230 V mains must be made
by authorised specialist personnel.
Check the system (roller shutters, awnings) regularly
for wear or damage.
The regulations of the local energy supply company
as well as the regulations for wet and damp rooms
according to VDE 0100 must be followed when making
the connections.
Only use unmodified original elero electrical parts.
Keep people away from the system until it is stationary.
When working on the system (servicing, cleaning
windows etc.), always disconnect it from the mains
supply.
Device function:
• Commissioning the drive with the assembly cable
• Quick limit switch adjustment
When the drive is shipped from the factory, the quick limit
position adjustment is active.
Only use this function for the first adjustment.
The limit switches do not switch over during the quick limit
position adjustment process. Run to the limit positions. Carry
out the re-adjustment via the limit switch adjusting screws after
deactivation of the quick limit switch adjustment.
Further limit position changes are only possible via the
limit switch adjusting screw.
Intended use
• Please ensure that the radio installations are not operated in
areas of increased possible interference.
(e.g. hospitals, airports ...).
• The radio control is only permitted for devices and units with which
a functional interference in hand-held/wall-mounted transmitters
or receivers poses no danger for persons, animals or materials or
where this risk is covered by other safety appliances.
• The operator has no protection whatsoever from interferences
by other radio emitters and local terminals (e.g. also from radio
installations), that are normally used on the same frequency
range.
• Only use radio receivers with equipment and units approved by
the manufacturer.
Optimal use of the radio signal
• Do not bend the antenna.
• Do not shorten or extend the antenna.
• If reception is poor, adjust the antenna.
• Install the antenna so that it is as exposed as possible.
• The minimum distance between two radio drives must be at
least 15 cm.
Installation
Observe the following installation instructions!
– The drive must be fixed in such a way that it does
not endanger personnel.
– Before installing the drive, all lines and equip-
ment, which are not required for operation, must
be removed from the site.
– During installation, during operation and when
work is carried out on the system, the opti-
on to separate all three poles from the mains
must always exist (Hirschmann connector and
Hirschmann coupling or a two-pole switch with
minimum 3 mm contact gap or all-pole main
switch).
– If the drive is controlled by a switch with OFF
pre-setting (dead man’s button), the momentary
contact switch must be fitted at a height of more
than 1.50 m and separated from the moving parts.
The travel range of the systems must always be
visible during operation.
– Moving parts in a drive, which are below 2.5 m,
must be protected.
– Set torque and set operating time must be
adapted to the requirements of the product which
is driven.
– Please note the technical data on the type plate.
– Please note that with this drive (type M and
L tubular motors) the smallest internal tube
diameter corresponds with 46 mm and 56 mm.
– The drive must be installed so that it cannot get
wet.
– Do not install drives in surroundings which are
at risk of explosion or in mobile appliances
(e.g. motor vehicles).
– Keep children away from the (remote) control unit.
Warning!
Remove of the motor cable plug
Risk of injury due to
electric shock.
When the motor cable plug is
removed the supply line must
have no voltage.
Warning!
Keep these instructions in a safe place!
After installation of the tubular drive attach these instruc-
tions to the cable fot the electrician.
→
→
→
138188206_EN_1112
Mounting and initial operation
Explanation of ProLine buttons
Hand-held/wall transmitter
elero
Auto
LR03 (AAA)
Programming button P
(Back of unit)
Programming
button P
Back of wall transmitter
3
2
1
3
2
1
Mains
Assembly cable connection
(only permissible for commissioning or setting procedures)
1.
Commissioning
Mains
2. Switch on mains.
Radio connection (transmitter operation)
3
2
1
3
2
1
2. Switch on mains.
2
Note: Before you put the drive into the radio mode, you must
set the end position.
Shaft assembly
Installation in profile tubes
① On round tubes, cut
a slot in the end of
the tubes on the drive
side (width 4 mm,
length 6 mm)!
② Push the drive
(do not knock in)
so that the drive lug
engages in the slot.
③ Screw on or rivet on the coupling
(adaptor)!
④ Attach the hangings to the shaft!
Run in the DOWN direction if it is necessary to install
the hangings on the winding shaft.
Secure the abutment against axial shifting by riveting or bolting
the cross member.
1
4
2
3
UP button
STOP button
DOWN
button
UP button
STOP button
DOWN
button
Blue (neutral wire) (1)
Black (2)
Brown (3)
Green-yellow
Blue (neutral wire) (1)
Black (2)
Brown (3)
Green-yellow
Mounting and initial operation
3
Note: The maximum limit switch range is 35 revolutions of the
shaft.
Use the adjusting tool for carrying out the adjustment.
Delivery status/factory setting
-
+
-
+
Quick limit switch
adjustment
position „On“
The quick limit switch
adjustment is activated at
the factory.
Releasing screw is in the
„On“ position.
The arrow of the releasing
screw points in the direc-
tion of the crown adaptor.
Limit switches are not
active in the quick limit
switch adjustment.
Adjusting tool
Adjusting tool
13 116.3801
Note: The limit switches will only work after the motor has been
installed in the shaft.
Quick limit switch adjustment
1. Attach the hangings to the shaft.
Run in the DOWN direction if it is necessary to move the
winding shaft.
2. Use the motor cable to move the hangings in the UP direction
until you reach the desired limit position.
3. Turn the releasing screw to the „Off“ position.
The arrow of the releasing screw points in the direction of the
cable.
Use an adjusting tool to do so.
4. Both limit positions are now roughly pre-set.
The fine adjustment must be carried out using the individual
adjusting screws.
Only at commissioning
-
+
-
+
Quick limit switch
adjustment
position ”Off“
4
Adjustment of the end positions
Checking the end positions
Allow the drive to run alternately in both directions until the limit
switch switches off.
-
+
-
+
Limit switch
adjustment screws
1. Allow the drive to run fully in the „Down“ direction.
2. Attach the roller shutter to the shaft.
3. Press the UP button on the assembly cable and keep it
depressed.
Setting of the upper end position
(Fine adjustment or end position changes)
Setting the lower end position
(Fine adjustment or end position changes)
4. Turn the adjusting tool of the UP limit switch adjustment screw
in the + or – direction until the end position is reached.
One turn of the limit switch adjustment screw represents
approx. 60° of turning of the winding shaft.
Limit switch
adjustment screws
1. Press the DOWN button on the assembly cable and keep it
depressed.
-
+
-
+
2. Turn the adjusting tool of the DOWN limit switch adjustment
screw in the + or – direction until the final end position is
reached.
One turn of the limit switch adjustment screw represents
approx. 60° of turning of the winding shaft.
The directional arrows show the corresponding travel direction of
the limit switch screws (4 mm Allen screws).
minus (–) = shorter travel
plus (+) = longer travel
Directional arrow
Adjusting tool
Adjusting tool
Directional arrow
Pages Preview: