EMI UNH-T2H-T3H-T4H Manuals
1 pdf manual(s) EMI UNH-T2H-T3H-T4H for free download (Document Types: Specifications)
EMI UNH-T2H-T3H-T4H Specifications [PDF] (6 pages)
- Identifier: id-262563
- Brand: EMI
- Device: EMI UNH-T2H-T3H-T4H Heat Pump
- Type: Specifications, PDF
- Key Aspects: Basic Configuration Guidelines, Control Panel and Interface Navigation, Critical Operational Precautions
- UPD Date: 16.04.2026
- Source File: 214097.pdf
- Pages: 6
- Description: Official user handbook for the EMI UNH-T2H-T3H-T4H.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Rome, New York, USA Enviromaster International LLC 1 emi ENGINEERING Submittal JOB NAME:______________________________________ LOCATION:________________________________________ PURCHASER:______________________________________________________________________________________ ENGINEER:________________________________________________________________________________________ SUBMITTED TO:__________________________________ FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY:__________________________________ DATE:____________________________________________ UNIT DESIGNATION: SCHEDULE #:_ _______________ MODEL #:_ ________________________________________ UNH-T2H-T3H-T4H Universal Air Handler Multi-Zone Limited Range Heat Pump Rev. B [10/08] Top Discharge Condensers Performance: ––––––––––––––––––––––––––––––––––––––––––––––––– Performance certified in accordance with ARI 210/240 Cooling Indoor design conditions: 80°F Dry Bulb / 67°F Wet Bulb Outdoor design conditions: 95°F Heating Indoor design conditions: 70°F Dry Bulb / 57°F Wet Bulb Outdoor design conditions (High): 47°F Dry Bulb / 43°F Wet Bulb Manufacturer reserves the right to change these specifications at any time without incurring obligation. UNH / T2H, T3H, or T4H System Capacities Model Cooling Heating Outdoor Indoor Air Handler Btuh (kW) SEER SHR EER Btuh (kW) HSPF COP T2H8800 (2) UNH24 36000 (10.5) 13 0.72 12.1 26800 (7.6) 7.7 3.3 T2H8400 (2) UNH24 42000 (12.3) 13 0.68 11.9 32000 (9.4) 7.7 3.2 T2H4400 (2) UNH24 48000 (14.0) 13 0.65 11.8 37400 (11.0) 7.7 3.2 T2H2400 (1) UNH12 (1) UNH24 35000 (10.2) 13 0.67 11.7 27800 (8.1) 7.7 3.2 T2H9800 (1) UNH09 (1) UNH24 27200 (8.0) 13 0.74 12.0 20800 (6.1) 7.7 3.3 T3H9990 (3) UNH09 27800 (8.1) 13 0.80 11.9 22200 (6.5) 7.7 3.3 T3H9920 (2) UNH09 (1) UNH12 29800 (8.7) 13 0.76 11.8 24000 (7.0) 7.7 3.3 T3H9980 (2) UNH09 (1) UNH24 36400 (10.7) 13 0.76 12.0 28200 (8.3) 7.7 3.3 T3H9940 (2) UNH09 (1) UNH24 42500 (12.4) 13 0.71 11.8 33400 (9.8) 7.7 3.2 T3H9220 (1) UNH09 (2) UNH12 31800 (9.3) 13 0.74 11.7 25800 (7.6) 7.7 3.3 T3H9280 (1) UNH09 (1) UNH12 (1) UNH24 38500 (11.3) 13 0.73 11.9 30000 (8.8) 7.7 3.3 Circuit Designators: 9 = 9000 Btuh 2 = 12000 Btuh 8 = 18000 Btuh 4 = 24000 Btuh (ex. - 8400 consists of one 18000 Btuh compressor and one 24000 Btuh compressor) UNH Chart continued next page .....
Similar Manuals in the Heat Pump Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Zodiac Z300 |
Air Conditioner #YN56BX |
96 | 115 | 29 | 02-07-2026 | view all manuals | |
Carrier 50VP |
50VP Installation manual - 8291H9 |
48 | 719 | 123 | 17-07-2026 | view all manuals | |
LG Hydro Kit |
Manual: LG Hydro Kit (123XL5, Upd.28-07-2026) |
77 | 1361 | 286 | 28-07-2026 | view all manuals | |
Carrier AQUAZONE 50KQE Series |
#UEJHLJ: AQUAZONE 50KQE Series Heat Pump Installation, operation and maintenance instructions |
32 | 174 | 39 | 29-06-2026 | view all manuals | |
Hitachi YUTAKI S Series |
Hitachi YUTAKI S Series Manual (Installation and operation manual), @8X8NL2 |
88 | 709 | 128 | 09-07-2026 | view all manuals | |
Emerson Comfort Alert 543-0033-00 |
Heat Pump #XWG7NW |
12 | 0.9 Mb | 168 | 41 | 02-07-2026 | view all manuals |