emmeti CS-11 Manuals

2 pdf manual(s) emmeti CS-11 for free download (Document Types: Operation & user’s manual)

emmeti CS-11 Operation & user’s manual Thumbnail

emmeti CS-11 Operation & user’s manual [PDF] (1 pages)

  • Identifier: id-1286793
  • Brand: emmeti
  • Device: emmeti CS-11 Thermostat
  • Type: Operation & user’s manual, PDF
  • Key Aspects: Step-by-Step Assembly Procedures, Manufacturer Contact and Support Data, Error Code Explanations
  • UPD Date: 09.03.2026
  • Source File: 1300909.pdf
  • Pages: 1
  • Description: Device operation guide for the emmeti CS-11.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
U9310090 M M M M M Your thermostat has the ability to reset all settings to the factory defaults. If you are certain you want to do this: In standby mode(when thermostat is turned off), press and hold button and for 5 seconds until RES is shown on LCD. Configure the menu Resetting factory defaults Setting temperature Press or once, you will see set temperature flashing. Use or again to adjust to the temperature you want your room to maintain. Press button to accept and exit. Buttons and LCD display Buttons Press < 5 seconds Press > 5 seconds Turning on/off thermostat Menu button Increase the set value Decrease the set value Lock /unlock buttons Reset to factory settings (when thermostat is turned off) + + Confirm settings The buttons are locked. Displays when heating is active Setback mode Symbol Description Set temperature Set At Sensor selection. This thermostat is a combination model allowing you to choose between 3 different models. (A, AF,F ) A model: air only, with built in sensor AF model: air & floor , with both built in and remote sensor F model: floor only, with remote sensor Press and hold button for 5 seconds. Now you can see Menu 01, to proeceed to other menu, press button again. To exit menu, press button First turn off the thermostat using the on/off button Menu # 01 Switching differential. Calibrate the room temperature. This feature is used to compensate for any difference Calibrate the floor temperature. This feature is used to compensate for any difference Set the floor temperature limit. Select temperature format 06 07 08 09 10 03 04 05 02 Feature Description Factory Default Feature Value 0°C 40 °C 4°C 10°C 35°C 2°C~ 7°C 10°C~ 20°C 20°C~ 35°C 20°C ~ 40 °C °C / °F °C A / AF / F A Press or to select The numbers of degree difference before switching. between the displayed room temperature and a thermometer. between the displayed floor temperature and a thermometer. This feature is to protect the floor surface. °C or °F. The default is 1°C which means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and will switch off 1°C above the set temperature. 1°C 1°C ~ 5°C -5°C ~ +5°C 0°C -5°C ~ +5°C Installation and Wiring Carefully separate the front half of the thermostat from the back plate by placing a small flat head terminal driver into the slots on the bottom face of the thermostat. Carefully unplug the ribbon connector which is plugged in to the front half of the thermostat. Place the thermostat front half somewhere safe. Make the wiring connections as Screw the thermostat back plate on to the back box. shown in the diagram below. Re-connect the thermostat ribbon cable and clip the CS-11 LCD Digital Setback Thermostat Frost protection. This is to avoid room temperature goes below 5°C. The setback amount( the amount of temperature reduction) on / off off Switched live output 230V ~ 50Hz L N Link terminals 1 to 3 for 230VAC live output Remote sensor for floor temperature control Timeswitch live for operation of temperature setback mode  Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW Tel: 01993 824900 : www.emmeti.co.uk : e: [email protected] This gives you the option to limit the minimum set temperature This gives you the option to limit the maximum set temperature 1. Please ensure that the electrical wiring of the installation and connections to and from the thermostat and any remote sensor connected to it are in accordance with BS 7671, the latest edition of the IET Wiring Regulations. 2. The thermostat must be wired to the electric mains through a switch capable of disconnecting all poles compliant with the current safety standards and with a contact separation of at least 3 mm in all poles. 3. Before commencing work on the installation, the electricity supply must be disconnected. 4. The depth of the back box should be 35mm minimum. WARNING Please Note: one of the following error messages will appear if one of these problems occur: E0, meaning the internal sensor is broken, short-circuit or not working properly. E1, meaning the floor sensor is broken, short-circuit, not connected, or not working properly. Single Zone Multi Zone 1 ErP Class +1% 8 ErP Class +5% two halves together.
emmeti CS-11 Operation & user’s manual Thumbnail

emmeti CS-11 Operation & user’s manual [PDF] (2 pages)

  • Identifier: id-1286794
  • Brand: emmeti
  • Device: emmeti CS-11 Thermostat
  • Type: Operation & user’s manual, PDF
  • Key Aspects: Component Longevity Optimization, Product Performance Metrics, FAQ Section for Common Queries
  • UPD Date: 08.07.2026
  • Source File: 1300908.pdf
  • Pages: 2
  • Description: Practical user guide for the emmeti CS-11.
Pages Preview:
  • emmeti CS-11 Operation & user’s manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
See overleaf for further setting up information Sensor selection. This thermostat is a combination model allowing you to choose between 4 different models. (A, AF,F ) A model: air only, with built in sensor AF model: air & floor , with both built in and remote sensor F model: floor only, with remote sensor Configuration Menu Turning ON/OFF Your Thermostat Press buttton to turn the thermostat ON or OFF. When thermostat is turned off, LCD will display OFF. This thermostat is full of useful features which can be set quite easily through the feature configuration menu. To access the feature configuration menu, simply turn off your thermostat and hold button M for 5 seconds. Now you can see Menu 1, to proeceed to other menu, press button M again. To exit menu, press button Menu # 1 Switching differential. Calibrate the room temperature. This feature is used to compensate for any difference Calibrate the floor temperature. This feature is used to compensate for any difference Set the floor temperature limit. Set backlight turning-on time. Selecting on will turn the light on continuously. Selecting off will turn the light off. Selecting 20 seconds will turn the light on for 20 seconds. Select temperature format Optimum start(preheat). This feature is to ensure that the required temperature has already been reached when you get up in the morning or come home from work. Select 12 / 24 hour clock 24 12 / 24 Pump protection(for hydronic heating only). In hydronic heating installations, it is recommended to activate the pump at least 15 seconds every 24 hours in order to avoid any seizing. Select ON to activate this feature, OFF to deactivate. When the thermostat is activating the pump, the icon will blink. 2 3 4 5 6 7 8 9 10 11 12 Feature Description Factory Default Feature Value 0°C OFF ON / OFF ON / OFF OFF 7_0 5_2 / 6_1 / 7_0 OFF ON / OFF 40 °C 20°C ~ 40 °C 20 seconds 20 seconds / ON /OFF °C / °F °C A / AF / F A Press or to select This product should be installed by a qualified electrician. The number of degrees difference between switching off at the between the displayed room temperature and a thermometer. between the displayed floor temperature and a thermometer. This feature is to protect the floor surface. °C or °F. Buttons and LCD display Buttons Short press Press > 5 seconds Turning on/off thermostat Menu button( when thermostat is turned off) Auto/Manual mode selection Increase the set value Bring up vacation mode Check floor temperature (AF model only) Decrease the set value Lock /unlock buttons Reset to factory settings (when thermostat is turned off) + + Set the time and week days Cancel override( when in override mode) Confirm settings M M The buttons are locked. Displays when heating is active Symbol Description Auto mode(use button M to select) Manual mode(use button M to select) Vacation mode Temporary temperature override Frost protection activated Set temperature The program number Program 1,2, 3,4,5,6 AUTO SET AT Program type selection. This gives user 3 options of program type. 5_2 will give you 5 days(Monday to Fiday) with the same six events(Wakeup, out, home, 6_1 will give you 6 days(Monday to Saturday) with the same six events(Wakeup, out, home, 7_0 will give you individual settings for each day from Monday to Sunday. out, home,sleep) and 2 days(Saturday and Sunday) with the same six events. out,home,sleep) and 1 day(Sunday) with the same six events. Frost protection. This feature is to avoid room temperature going below 5°C E0 = The internal sensor has developed a fault. You should contact your thermostat retailer for assistance. E1 = The remote floor sensor has not been connected, has been wired incorrectly or the probe is faulty. LO = The room or floor temperature is below 0 Error Message °C HI = The room or floor temperature is above 50 °C Program button( when thermostat is turned on) means the thermostat will switch the heating on 0.5°C below the set temperature and will turn it off 0.5°C above the set temperature. With a 2°C differential, the heating will switch on 1°C below the set temperature and switch off 1°C above the set temperature. 1°C 1°C ~ 5°C -5°C ~ +5°C 0°C -5°C ~ +5°C CS-11 LCD 7-Day 5+2 Programmable Digital Thermostat U9310044 Registered Address: 6 Tannery Yard, Witney Street, Burford, Oxon., OX18 4DW Tel: 01993 824900 : www.emmeti.co.uk : e: [email protected] Temporary set temperature and on again to reach the set temperature.The default is 1°C which

Similar Manuals in the Thermostat Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Honeywell L4188A

#7G2U9K: L4188A Controller Manual 

8 540 114 31-03-2026 view all manuals
Honeywell 191108AJ

191108AJ (Thermostat ePDF Manual, #S5COK5)

28 0.39 Mb 1120 180 05-08-2026 view all manuals
Danfoss ECL Comfort A315

#114EHF: ECL Comfort A315 Controller Installation manual

32 265 48 23-03-2026 view all manuals
Vemer Tuo Wi-Fi Batteria Bianco

Vemer Thermostat Operation & user’s manual (File: PDF, 06-06-2026)

40 1025 154 06-06-2026 view all manuals
Carrier TSTTCCPB101

Carrier TSTTCCPB101 Manual (Operation & user’s manual), @1DKHJH

18 0.31 Mb 1143 229 26-05-2026 view all manuals
Conrad 61 05 78

61 05 78 (Thermostat ePDF Manual, #43Q873)

96 1409 268 08-08-2026 view all manuals