EPH R27-VF Manuals

1 pdf manual(s) EPH R27-VF for free download (Document Types: Operating instructions)

EPH R27-VF Operating instructions Thumbnail

EPH R27-VF Operating instructions [PDF] (2 pages)

  • Identifier: id-1576565
  • Brand: EPH
  • Device: EPH R27-VF Controller
  • Type: Operating instructions, PDF
  • Key Aspects: Device Specifications Overview, Technical Data and Parameters, Component Overview and Descriptions
  • UPD Date: 04.08.2026
  • Source File: 1424708.pdf
  • Pages: 2
  • Description: Complete instruction guide for the EPH R27-VF.
Pages Preview:
  • EPH R27-VF Operating instructions preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
CAUTION! Before commencing, disconnect the device from the mains. There are parts that carry mains voltage behind the cover. Never leave unsupervised when it is open. (Prevent non specialists and especially children from gaining access to it.) Never remove this product from the electrical baseplate. Disconnect from mains supply in the event of any damage to any buttons. Do not use sharp tools to push any button. R27-VF - 2 Zone Programmer Operating Instructions Page 1 of 2 Press the or buttons to adjust the P1 ON time. Press the or buttons to adjust the P1 OFF time. Repeat this process to adjust the ON & OFF times for P2 & P3. Press and repeat the above process to adjust for Zone 2. When completed, move the selector switch to the RUN position. 1. Factory default settings 6. Adjusting the program settings 2. Factory program settings Program: 5/2D Backlight: On Keypad: Unlocked Frost Protection: Of Lower the cover on the front of the unit. Move the selector switch to the PROG SET position. You can now programthe Zone 1. Copy function may only be used if the programmer is in the 7d mode. Lower the cover on the front of the programmer. Move the selector switch to the PROG SET position. Set the ON & OFF times for the day of the week you wish to copy from. Press the button for 2 secs. The next day of the week will begin to fash. Press the button to copy the ON & OFF to this day. Press the button to skip a day. ON & OFF times can be copied to multiple days by using the button. Press the button when copying has been completed. When completed, move the selector switch to the RUN position. RUN CLOCK SET PROG SET Holiday COPY 7. Copy function 3. Resetting the programmer Press Press This 2 zone programmer is designed to provide ON/OFF control for 2 zones, with the value added application of in built frost protection. It is necessary to press the RESET button prior to initial programming. This button is located behind the cover on the front of the unit. AUTO The programmer operates 3 ‘ON/OFF’ periods per day. ALL DAY The programmer operates 1’ON/OFF’ period per day. This operates from the frst ON time to the third OFF time. ON The programmer is permanently on. **ON** OFF The programmer is permanently of. **OFF** Lower the cover on the front of the unit. By pressing the button, you can change between AUTO / ALL DAY / ON / OFF for Zone 1. Repeat this process for Zone 2 by pressing the button. 5. ON/OFF period selection There are 4 modes available on this programmer for users to choose for their individual application. Contents 1. Factory default settings 2. Factory program settings 3. Resetting the programmer 4. Setting the date and time 5. ON/OFF period selection 6. Adjusting the program settings 7. Copy function 8. Reviewing the program settings 9. Boost function 10. Advance function 11. Holiday mode 12. Backlight mode selection 13. Keypad lock and unlock 14. Frost protection function 15. Master reset 4. Setting the date and time Press Press Press Press Press Press Lower the cover on the front of the unit. Move the selector switch to the CLOCK SET position. Press the or buttons to select the day. Press the or buttons to select the month. Press the or buttons to select the year. Press the or buttons to select the hour. Press the or buttons to select the minute. Press the or buttons to select 5/2D, 7D or 24H The date, time and function are now set. Move the selector switch to the RUN position to run the program, or to the PROG SET position to change the program setting. RUN CLOCK SET PROG SET Important: Keep this document RUN CLOCK SET PROG SET Mon-Fri Sat-Sun 5/2D P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF 6:30 8:30 12:00 12:00 16:30 22:30 7:30 10:00 12:00 12:00 17:00 23:00 All 7 days 7D P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF 6:30 8:30 12:00 12:00 16:30 22:30 Everyday 24H P1 ON P1 OFF P2 ON P2 OFF P3 ON P3 OFF 6:30 8:30 12:00 12:00 16:30 22:30 EPH Controls Ireland [email protected] www.ephcontrols.com EPH Controls UK [email protected] www.ephcontrols.co.uk 20180621_R27-VF_OpIns_JW

Similar Manuals in the Controller Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Mitsubishi Electric MELSEC iQ-F Series

MELSEC iQ-F Series (Controller ePDF User Guide, #ZRF181)

56 90 23 15-05-2026 view all manuals
Parker 690+ series

690+ series Safety & quickstart - JTC5BP

32 601 145 01-07-2026 view all manuals
Kieback&Peter MD15/230

Kieback&Peter Controller Product description (File: PDF, 30-08-2026)

12 1093 208 30-08-2026 view all manuals
Johnson Controls VMA 1410

PDF Guide (@972879), Johnson Controls VMA 1410 Control Unit (11-04-2026)

35 323 65 11-04-2026 view all manuals
Analog way Axion2

Analog way Axion2 User Guide (Operation & user’s manual), @PDK1Z7

52 492 99 12-04-2026 view all manuals
Donaldson Torit DCE 2000 Series

User Guide: Donaldson Torit DCE 2000 Series (N53KB6, Upd.16-08-2026)

30 142 36 16-08-2026 view all manuals