Escali M3315 Manuals

2 pdf manual(s) Escali M3315 for free download (Document Types: Product manual, Operating manual)

Available Documents for M3315:

Escali M3315 Product manual Main Page Preview

Product manual [PDF] (4 pages)

  • Brand: Escali
  • Model: M3315
  • Format: PDF
  • Key Aspects: System Limitations and Considerations, Standard Operating Procedures, Documentation and Revision History
  • Updated: 14.08.2026
  • Source File: 1252899.pdf
  • Pages: 4
  • Description: Installation and maintenance guide for the Escali M3315.

Document Preview & Text Transcription

ESCALI CORPORATION 3203 Corporate Center Drive, Suite 150 Burnsville, MN 55306 USA PRODUCT SUPPORT 24/7 Online support: https://escali.zendesk.com Email support: [email protected] Phone support: 1-800-467-6408 2 YEAR PROFESSIONAL GUARANTEE This scale is guaranteed to be free of defects in materials and workmanship. For more details visit: www.escali.com/warranties Escali’s liability is limited to two (2) times the cost of the product. © Escali Corp., Minneapolis, MN, USA. All rights reserved. Escali, the Escali logo and other Escali marks are owned by Escali Corp. and may be registered. M-Series Multifunctional Digital Scale www.escali.com PRODUCT MANUAL 2 BATTERY INSTALLATION 1. Turn the entire scale upside down, and set it securely on a firm, flat surface. 2. Open the battery door by loosening the battery door screw. 3. Install four UM2 size C batteries in the battery compart- ment, ensuring that the positive/negative side is in the direction as shown in the cabinet. 4. Close the battery door and fasten it with the screw. BATTERY STATUS  When the batteries are low, the message “Lo” will be displayed. Open the battery compartment, and replace the old batteries with new ones.  Used batteries must not be disposed of as household waste. Do not incinerate batteries, because they might explode at high temperature. Contact your local recy- cling center for more information concerning reclama- tion, and disposal of batteries.  When replacing batteries, always use brand new batter- ies of the same type. AC/DC ADAPTER (OPTIONAL) 1. Open the adapter cabinet door 2. Plug the adapter jack into the socket. 3. Take out the adapter, and close the cabinet door. 4. Plug the adapter to the AC main LEVEL THE SCALE When the scale is put to use at a new location, adjust the level of the scale by turning the 4 level adjusting feet until the bubble is located in the middle position of the bubble leveler. 7 NOTES: 6 10) Level Adjusting feet 1) Stainless Steel Platform 2) Bubble Leveler 3) LCD Display 4) Keypad 5) Battery door compart- 6) Main Power On/Off Switch 7) Adapter Door 8) AC/DC Adapter Socket 9) AC/DC Adapter PART AND KEY DESCRIPTION PRODUCT SPECIFICATIONS Model: M3315 Capacity: 33 lb / 15 kg Graduation: 0.2 oz / 5 g Product Dimensions: 10.25” x 11.75” x 4.25” Platform Dimensions: 8.25” x 10.25” Power Source: (4) C Batteries, Optional 9-volt wall adapter Automatic shut-off: 2 minutes NSF Certified Model: M6630 Capacity: 66 lb / 30 kg Graduation: 0.2 oz / 5 g Product Dimensions: 10.25” x 11.75” x 4.25” Platform Dimensions: 8.25” x 10.25” Power Source: (4) C Batteries, Optional 9-volt wall adapter Automatic shut-off: 2 minutes NSF Certified 3 ACTIVATING THE SCALE 1. Turn on the “power on/off switch” 2. Turn the scale on by pressing ON/OFF key. 3. The LCD screen will show all characters for a few seconds, and then “0.000►” will be shown on the display. 4. The scale turns off automatically after being idle for two min- utes. BACK LIGHT You can turn the back light on or off by pressing the BACK LIGHT key. WEIGHING AN ITEM 1. Turn on the scale. 2. Place an item on the platform. 3. Exact weight of the item will be displayed. SELECTING WEIGHT UNIT When the scale is powered on, press the MODE key to change weight unit according to the following sequence: kg —- lb —- oz —- lb/oz USING THE HOLD FUNCTION When the item is on the scale platform, press the HOLD key once and then remove the item from the scale platform. The weight of the item will be held for 10 seconds with a “HOLD” icon displayed on the left side of the LCD. POWER OFF 1. The scale can be powered off manually by pressing the ON/OFF key. 2. For a total shut down; use the power switch on the side. 4 USING THE TARE MODE: 1. Turn the scale on. 2. “0.000►” will be shown on the display after a few seconds. 3. Place an item on the weighing platform, and read the value ac- cordingly. 4. Press the TARE key; the weight of the item will be eliminated, and the reading will change to “0.000►”. 5. Place next item on the weighing platform, and note the reading. 6. Press TARE key again to show the total weight. 7. Repeat steps (4) to (6) when adding more items. Note: The scale will display a negative reading when you remove all items. Press the TARE key once, and the negative read- ing will disappear. USING THE COUNTING MODE: A. SET SAMPLE SIZE 1. Turn on the scale. 2. Press and hold the PCS key for about 3 seconds until a flash- ing number is displayed. 3. Press the MODE key to select the sample size in the sequence of 10 → 20 → 40 → 60 → 80 → 100 4. Once you have determined your desired sample size; place the samples on the platform. (Example: For a sample size of 10, place quantity of 10 onto the platform, for sample size of 20, place quantity of 20, etc.) 5. Press the PCS key to confirm the sample size. You can now add, and subtract samples. 6. Press the PCS key again to return to weighing mode. Remark: The sample weight is memorized in the scale. You only need to repeat steps (2), (4), and (5) for different objects or sample size. 5 B. COUNTING 1. Turn on the scale. 2. Press the PCS key; the sample size set previously by the setting above will be memorized. 3. Place items onto the platform; the scale will calculate, and display the item count on the LCD. Remark: By pressing the TARE key; this will activate the accumu- lation of counting. See Tare Mode Steps In order to ensure accurate counting figure, the minimum unit sample weight must > ld, and the counting size must not exceed 65535pcs. If over 65535pcs, the LCD will display “- - - -” PROPER USE & CARE  Use and stow the scale at room temperature.  Use on a flat, level, and stable surface.  The scale is an instrument of precision. Do not submit the scale to shaking, excessive vibration or other rough treatment.  The display may be affected by electromagnetic disturbances such as radios, microwaves, or cell phones. If such distur- bances occur, remove the source of the disturbance, and restart the scale.  Disassembling or tampering with the scale voids the warranty.  Clean the scale with dish soap, and a damp cloth.  Do not submerge in liquid; the scale is not waterproof. WARNING MESSAGES EEEE Overload warning Out2 Load cell is damaged or needs recalibration Unst The scale is in a unstable environment Lo Low battery warning
Escali M3315 Operating manual Main Page Preview

Operating manual [PDF] (4 pages)

  • Brand: Escali
  • Model: M3315
  • Format: PDF
  • Key Aspects: Package Contents and Accessories List, Common Issue Diagnostic Flows, Product Performance Metrics
  • Updated: 13.06.2026
  • Source File: 231036.pdf
  • Pages: 4
  • Description: General instruction manual for the Escali M3315.

Document Preview & Text Transcription

DIGITAL COUNTING SCALE M - Series OPERATING MANUAL INTRODUCTION Congratulations on your purchase of our Multifunctional Scale. In order to ensure the scale continues to deliver peak performance, please read these operation instructions carefully and thoroughly prior to initial usage. IMPORTANT 1. Read all instructions before operating the scale. 2. Follow the basic safety precautions for all office equipment when using this scale. 3. The manufacturer does not warrant this unit to be waterproof. Do not expose this product to rain or moisture. 4. Do not use the scale in direct sunlight. Keep it away from heating appliances such as an oven, stove, etc. 5. This scale does not contain any user-serviceable parts. Do not disassemble. 5. Use the scale for its intended purpose only. Note: The display value may be affected by electromagnetic influences, e.g. when a radio is operated in the immediate vicinity of the device. The product can be used for its intended purpose again when the interference is discontinued, but may need to be switched on again to re-start. BATTERY INSTALLATION 1. Turn the entire scale upside down and reset it securely on a firm, flat surface. 2. Open the battery door by loosing the battery door screw. 3. Install four UM2 size C batteries in the battery compartment, ensuring that the positive/negative side is in the direction as shown in the cabinet. 4. Close the battery door and fasten it with the screw. BATTERY STATUS • When the battery is low, “Lo” will be displayed. Open the battery compartment and replace the old batteries with new ones. • Used batteries must not be disposed of as household waste. Do not incinerate batteries because they might explode at high temperature. Contact your local authority for information concerning reclamation and disposal of batteries. • When replacing batteries, always use brand new batteries of the same type. AC/DC ADAPTOR (Optional) 1. Open the Adaptor cabinet door. 2. Plug the adaptor jack into the socket. 3. Take out the adaptor and close the cabinet door. 4. Plug the adaptor to the AC main. PART AND KEY DESCRIPTION 1) Stainless Steel Platform 2) Bubble Leveler 3) Liquid Crystal Display (LCD) 4) Keypad 5) Battery Door and Compartment 6) Main power On/off Switch 7) Adaptor door 8) AC/DC adaptor socket 9) AC/DC adaptor (optional) 10) Level adjusting feet (6) Main Power On/Off Switch (7) Adaptor Door (9) AC/DC adaptor (8) AC/DC Adaptor Socket (10) Level Adjusting feet (5) Battery Door and Compartment Bubble Leveler (2) LCD Display (3) Keypad (4) (1) Stainless Steel Platform OPERATION LEVEL THE SCALE When the scale is put to use at a new place, adjust the level of the scale by turning the 4 level adjusting feet until the bubble is located in the middle position of the bubble leveler. ACTIVATING THE SCALE 1. Turn on the “power on/off switch” 2. Turn the scale on by pressing “ON/OFF” key 2. The LCD screen will show all characters for a few seconds and then “0.000►” will be shown on the display. 3. The scale turns off automatically after being idle for two minutes. EL BACK LIGHT Your can turn On or Off the Back light of the scale by pressing the “Back Light” key WEIGHING AN ITEM 1. Turn on the scale. 2. Place an item on the platform and the exact weight of item will be displayed. SELECTING WEIGHT UNIT When the scale is power on, press the “MODE” key repeatedly to change weight unit according to following sequence: kg --- lb --- oz --- lb/oz Displays 4 modes, e.g. “kg” mode F 1.500kg “lb” mode F 3.32lb “oz” mode F 52.9oz ”lb/oz mode F 3lb 4.9oz USING THE HOLD FUNCTION When the object is on the scale platform, press the “HOLD” key once and then take off the object from the scale platform. the weight of the object will be hold for 1 minute with a HOLD icon displays on the left side of the LCD. USING THE TARE MODE: 1. Turn the scale on. 2. “0.000►” will be shown on the display after a few seconds. 3. Place an item on the weighing platform and read the value accordingly. 4. Press the “TARE” key, the weight of this item will be eliminated and the reading will change to “0.000►”. 5. Place next item on the weighing platform and get the reading. 6. Press “TARE” key again will show the total weight 7. Repeat step (4) to (6) for further objects. Note: The scale will display a negative reading when you remove all items. Press the “Tare” key once and the negative reading will disappear.

M3315: Related Instructions

Manuals from Other Manufacturers