Euroterm 2604 Manuals
1 pdf manual(s) Euroterm 2604 for free download (Document Types: Installation and wiring instructions)
Euroterm 2604 Installation and wiring instructions [PDF] (2 pages)
- Identifier: id-827654
- Brand: Euroterm
- Device: Euroterm 2604 Controller
- Type: Installation and wiring instructions, PDF
- Key Aspects: Periodic Inspection Checklists, End-of-Life Handling and Disposal, Risk Mitigation and Accident Prevention
- UPD Date: 07.07.2026
- Source File: 812108.pdf
- Pages: 2
- Description: User handbook for the Euroterm 2604.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
VL SUPPLY VOLTAGE OPTION This is suitable for connection to a power supply of 24Vac -15,+10% 48-62Hz or 24Vdc -15,+20%, 20W maximum. Note. This MUST be fused using a T type fuse (EN60127 time-lag type) rated at 4A. ! Caution Ensure that mains supplies are connected to the power supply terminals (100 to 230Vac only), the fixed relay terminals or to relay or triac modules. Under no circumstances should mains supplies be connected to any other terminals. A protective Earth connection is required. ALWAYS ensure that the protective Earth is fitted first and disconnected last. INSTALLATION CATEGORY AND POLLUTION DEGREE This unit has been designed to conform to BS EN61010 installation category II and pollution degree 2. These are defined as follows: � Installation category II. The rated impulse voltage for equipment on nominal 230V ac mains is 2500V. � Pollution degree 2. Normally, only non-conductive pollution occurs. However, a temporary conductivity caused by condensation must be expected. PERSONNEL Installation MUST only be carried out by qualified personnel. ENCLOSURE OF LIVE PARTS To prevent hands or metal tools touching parts that may be electrically live, the unit must be installed in an enclosure. WIRING It is important to connect the unit in accordance with the data on this sheet, ensuring the protective Earth connection is ALWAYS fitted first and disconnected last. Wiring MUST comply with all local wiring regulations, i.e. UK, the latest IEE wiring regulations (BS7671), and USA, NEC Class 1 wiring methods. Only use copper conductors for connections. Terminal tightening torque 0.4Nm (3.5lbin) max. Caution Do not connect AC supply to low voltage sensor input or low level inputs and outputs. POWER ISOLATION The installation must include a power isolating switch or circuit breaker. This should be in close proximity (1 meter) to the unit, in easy reach of the operator and marked as the disconnecting device for the unit. OVERCURRENT PROTECTION It is recommended that the power supply to the system is fused appropriately to protect the cabling to the unit. CONDUCTIVE POLLUTION Electrically conductive pollution, i.e. carbon dust, MUST be excluded from the enclosure in which the unit is installed. To secure a suitable atmosphere in conditions of conductive pollution, fit an air filter to the air intake of the enclosure. Where condensation is likely, include a thermostatically controlled heater in the enclosure. OVER-TEMPERATURE PROTECTION When designing a contol system it is essential to consider the consequences should any part of the system fail. In temperature control applications the primary danger is the heating will remain constantly on. This could spoil the product, but more seriously damage the process machinery being controlled, or even cause a fire. This may occur if the, � temperature sensor is detached from the process � thermocouple wiring has short circuited � unit fails with the heating output constantly on � external valve or contactor is sticking in the heating condition � unit setpoint is set to high Where damage or injury can occur, it is recommended that a separate over-temperature protection unit, and independant temperature sensor, to isolate the heating circuit, is fitted. Note. Alarm relays within the unit will not indicate all failure conditions. INSTALLATION REQUIREMENTS FOR EMC To comply with European EMC directive certain installation precautions are necessary: � General guidance. Refer to EMC Installation Guide, Part no. HA025464. � Relay outputs. It may be necessary to fit a suitable filter to suppress conducted emissions. Filter requirements depend on the type of load. � Table top installation. If using a standard power socket, compliance to commercial and light industrial emissions standard is usually required. To comply with conducted emissions standard, a suitable mains filter must be installed. Installation Safety Requirements Various symbols used on the instrument are described below: ! Caution (refer to the accompanying documents) Protective earth terminal Functional (ground) earth MANUFACTURING ADDRESS U.K. Worthing Eurotherm Limited Telephone: (+44 1903) 268500 Fax: (+44 1903) 265982 E-mail: [email protected] Web: www.eurotherm.com General This unit is intended for Industrial Temperature and Process Control applications, within the requirements of the European Directives on Safety and EMC. Warning The Safety and EMC protection provided can be seriously impaired, if the unit is not used in the manner specified. The installer MUST ensure the Safety and EMC of the installation. UNPACKING AND STORAGE If on receipt, the packaging or unit are damaged, do NOT install, but contact the supplier. If being stored before use, protect from humitity and dust in an ambient temperature range of -30ºC to +75ºC. Caution: Electrostatic discharge Always observe all electrostatic precautions, before handling the unit. SERVICE AND REPAIR The unit has no servicable parts. Contact the supplier for repair. CLEANING Use Isolpropyl Alcohol to clean label. Labels will become illegible if water or water based products are used. Use a mild soap solution to clean other exterior surfaces. © Copyright Eurotherm Limited™ 2013 All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be stored in a retrieval system other than for the purpose to act as an aid in operating the equipment to which the document relates, without the prior written permission of Eurotherm Limited. Eurotherm Limited pursues a policy of continuous development and product improvement. The specification in this document may therefore change without notice. The information in this document is given in good faith, but is intended for guidance only. Eurotherm Limited will accept no responsibility for any loses arising from errors in this document. Power Supply Note. Labels may differ between communication protocol variants. POWER SUPPLY SPECIFICATION VH SUPPLY VOLTAGE OPTION This is suitable for connection to a power supply of between 100 and 230Vac ±15%, 48 to 62 Hz, 20W maximum. Note. This MUST be fused using a T type fuse (EN60127 time-lag type) rated at 1A. Digital I/O Terminals The eight digital I/O connections provided can be individually configured as, � Input. Inputs are Logic (-1 to 35Vdc) or Contact Closure, and can be configured for Manual, Remote, Run, Hold, Reset, etc, � Output. Outputs are open collector requiring an external power supply, and can be configured as event Alarms, Time proportioning or valve position outputs. Note. These terminals are NOT isolated from the Instrument ground. DIGITAL INPUTS Common Logic Inputs See Note 1, & 2 Common Contact Closure Inputs See Note 1 See Note 3 Notes Digital Inputs 1 Logic Inputs or Contact Closure can be wired in any combination. 2 Logic Inputs can accept drive signals from a voltage source Voltage Drive Signal Limits <2V Active (1) -1V >4V Inactive (0) +35V 3 D8 supports Digital Inputs Only. Thyristor Unit Thyristor Unit S S R S S R Relay Relay Relay External P S U Notes Digital Outputs 1 Relay, Thyristor or Solid State Relay (SSR) Drive can be wired in any combination. 2 Digital Outputs support 10 to 35Vdc External Power Supply Unit (PSU) 3 Each output is current limited to 40mA. See Note 2 I/O Expander Terminals DATA TRANSFER The primary use of the I/O Expander terminals (E1 and E2) is to connect an I/O Expander Module (Model No 2000IO). This adds a further 20 digital inputs and 20 digital outputs to this instrument. Data transfer is performed serially via a two wire interface from instrument to expander. DIGITAL INPUT These terminals can only be used as a secondary digital input if the I/O Expander is not fitted. If used in this way simply connect a 2K2, ¼W limiting resistor in series with the input. To I/O Expander Module 2K2 Limits -1V, +35V COMMUNICATIONS SEE COMMUNICATIONS - DEVICENET™, MODBUS/TCP, MODBUS AND EI-BISYNCH, AND PROFIBUS™ Process Variable (PV) Input Terminals The fixed Process Variable (PV) input terminals can be configured for Thermocouple, PRT (Pt100), Pyrometer, Voltage (e.g. 0-10Vdc) or Milliamp (e.g. 4-20mA) and vacuum - log10 signals. These sensors are used to provide inputs to Control Loop 1. Note. The terminals are isolated from the Digital I/O. If using shielded cables, only ground one end to avoid ground loop currents. Voltage (V) Current (mA) See Note 4 + - 2.49ΩΩΩΩΩ mA + - V Milli-volts (mV) + - m V See Note 5 Notes 1 Use appropriate compensating cable when configuring and extending a Thermocouple input. 2 Operating range between 0V to 10V or 0V to 2V. 3 Operating range up to 80mV. 4 Operating range between 0 to 20mA or 4 to 20mA. 5 A link MUST be fitted between V+ and V- if using a 2-wire PRT. The resistance of each wire in a 3-wire PRT must be the same. 6 Do NOT run power and signal cables together. 2-, 3-wire Platinum Resistance Thermometer (PRT) Thermocouple or Pyrometer See Note 1 + - See Note 3 See Note 2 MODULES SEE PLUG-IN I/O MODULES Note. Module position 2 is for future expansion. 24Vac (-15,+10%) or 24Vdc (-15,+20%) 100 to 230Vac Relay Terminals These terminals can be configured as a control output, an alarm, or event output. A single changeover relay is provided as standard. Notes 1 Connect the Power Supply last to avoid electrical damage. 2 Use copper conductors only. 3 Do NOT run power and signal cables together. Common Normally Open (NO) Normally Closed (NC) Relay Rating Max - 264Vac, 2A Min - 1V, 1mA Analogue Input Terminals The Analogue Input Terminals (BA and BB) accept volts, e.g. 0-10Vdc, or Milliamp, e.g. 4-20mA, signals. The signals can be used for remote setpoint input, remote setpoint trim or as a high level PV input to a control loop and can be characterised to match a particular curve from a transmitter. Note. The terminals are NOT isolated from the Digital I/O and do NOT support direct input from a Thermocouple. Notes 1 To earth screened cables, connect the screen at supply end. 2 To earth screened cables, connect the screen to terminal BC. Isolated Voltage (0V - 10V) Non-Isolated Current (0 - 20mA) (4 - 20mA) See Note 1 + - 100ΩΩΩΩΩ Isolated Current (0 - 20mA) (4 - 20mA) + - See Note 2 Non-Isolated Voltage (0V - 10V) See Note 1 + - + - See Note 2 100ΩΩΩΩΩ DIGITAL OUTPUTS + - Note Wiring Specifics. All electrical connections made to screw terminals protected by a clear plastic hinged cover, used to prevent accidental contact with live wires. The terminals accept wire sizes from 0.5 to 1.5mm2 (16 to 22 AWG) and should be tightened to a torque of 0.4Nm (3.5lbin). If using crimp connectors, the correct size is AMP, part number 349262-1. High Voltage Supply Low Voltage Supply Legend Supply Legend Supply L Line 24 24V ac/dc N Neutral 24 24V ac/dc Earth Earth - + 2604/2704 HIGH PERFORMANCE CONTROLLER/PROGRAMMER INSTALLATION AND WIRING INSTRUCTIONS These instruments are modular, fully configurable, high accuracy, high stability temperature and process controllers, available in a single, dual or three loop format. Each unit is supplied as a specific hardware configuration, e.g. there are five ‘slots’ that contain specific plug in modules, identified by a hardware code printed on the label on the side of the controller at time of ordering. The unit can also be supplied with pre-configured software for some simple applications according to an optional Configuration Code, or configured via the front panel or iTools Engineering Studio. The 2604 has a dual 7-segment display of process value and setpoint with a LCD panel for display of information and user defined messages. The user interface is menu driven via the display and seven front panel keys. Part No. HA029465 (CN29750) Issue 3 Mar 13 The 2704 has a 120 x 160 pixel electroluminescent display of all process value and setpoint information and user defined messages. The user interface is menu driven via the display and seven front panel keys. FEATURES INCLUDE: � Advanced ramp/dwell programmer with storage of up to 50 programs for the 2604 and 60 programs for the 2704. � Application specific controllers (including Handbook), i.e. Vacuum Furnace, Carbon Potential, Humidity, Boiler (TDS) and Melt Pressure. � A wide variety of configurable inputs, including thermocouples, Pt100 resistance thermometers (PRT) and high level process inputs. � Loop configuration as PID, On/Off or motorised valve position, with control of strategies including single, cascade, override and ratio control. � PID control outputs can be relay, logic, triac or dc with motorised valve position outputs being relay triac or logic. � Simplified commissioning and optimised process available via Auto Tuning and PID gain scheduling. Note. Refer to the Engineering Handbook for Operation and Configuration details, available on the enclosed CD (Part No. LA029175) or via the website. 2704 2604 WARNING This instrument is fitted with a back up battery which should be changed at regular intervals. It is important to maintain a record of instrument configuration or, preferably, a clone file which can be re-loaded after a battery change or any other maintenance. The battery is not serviceable, contact your local service centre to make suitable arrangements. For further information see the User Manuals at www.eurotherm.co.uk
Similar Manuals in the Controller Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Roger Technology H70/200AC |
Roger Technology Controller Instruction and warnings for the installer (File: PDF, 13-03-2026) |
172 | 539 | 108 | 13-03-2026 | view all manuals | |
Siemens Simatic ET 200S |
PDF User Manual (@BA75NH), Siemens Simatic ET 200S I/O Systems (27-03-2026) |
320 | 199 | 44 | 27-03-2026 | view all manuals | |
EOS Infratec Classic |
#556A4E: Infratec Classic Controller Assembly and operating instruction |
41 | 374 | 83 | 24-04-2026 | view all manuals | |
GE C30 |
PDF User Manual (@D16FA9), GE C30 Controller (06-04-2026) |
392 | 1114 | 190 | 06-04-2026 | view all manuals | |
Eaton A201 |
A201 Instruction leaflet - W99PA8 |
6 | 904 | 154 | 12-05-2026 | view all manuals | |
Chamberlain MyQ |
MyQ Troubleshooting manual - X6D4C7 |
5 | 908 | 200 | 05-05-2026 | view all manuals |