Evco EVJ254 Manuals

1 pdf manual(s) Evco EVJ254 for free download (Document Types: Manual )

Evco EVJ254 Manual  [PDF] (4 pages)

  • Identifier: id-1787313
  • Brand: Evco
  • Device: EVJ254 Controller
  • Type: PDF
  • Key Aspects: User Training Recommendations, Standard Operating Procedures, Error Code Explanations
  • UPD Date: 23.06.2026
  • Source File: 1752961.pdf
  • Pages: 4
  • Description: Product operation guide for the Evco EVJ254.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
EVCO S.p.A. | EVJ254 | Instruction sheet ver. 1.0 | Code 104J254I103 | Page 1 of 4 | PT 13/18 EVJ254 Controllers for refrigerated cabinets with variable speed compressors EN ENGLISH - Controllers for low temperature units. - Power supply 230 VAC. - Incorporated clock (according to the model). - Cabinet probe and evaporator probe (PTC/NTC). - Door switch input. - Capable of managing Embraco and Secop variable speed compressors. - Alarm buzzer. - TTL MODBUS slave port for EVconnect APP or BMS. - Port for SD card data-logger module EVBD05 (according to the model). - Models in plastic container or open-frame (according to the model). 1 MEASUREMENTS AND INSTALLATION | Measurements in mm (inches) 1.1 Models in plastic container for front installation Front installation on a plastic or metal panel (with elastic holding flaps). N.B. The thickness of a metal panel must be between 0.8 and 1.5 mm (1/32 and 1/16 in), while that for a plastic panel must be between 0.8 and 3.4 mm (1/32 and 1/8 in). 1.2 Models in plastic container installed from behind Installed from behind a glass or methacrylate panel (with biadhesive) customizing the keys on the front of the unit. N.B. - The thickness of a glass panel must be between 2.0 and 4.0 mm (1/16 and 1/8 in), while that for a methacrylate panel must be between 2.0 and 3,0 mm (1/16 e 1/8 in) - The panel and the material used to make screen printing must not contain conductive substances - Keep the device and the panel at a temperature between 15 and 38 °C (59 and 100 °F) about an hour before the installation - Before the installation clean the panel surface in contact with the biadhesive carefully, making sure the product used to clean is suitable for the panel material (we recommend using isopropyl alcohol, hydrocarbon solvent in case of greasy surfaces); keep cleaning with a cloth as long as it results clean and dry after the use - During the installation, exert a uniform and constant pressure about 30 s on the panel surface in contact with the biadhesive; later keep the device and the panel horizontally about 48 h at a temperature between 15 and 38 °C (59 and 100 °F). 1.3 Open-frame models To be installed from behind, with threaded studs and membrane keypad. INSTALLATION PRECAUTIONS - Ensure that the working conditions are within the limits stated in the TECHNICAL SPECIFICATIONS section. - Do not install the device close to heat sources, equipment with a strong magnetic field, in places subject to direct sunlight, rain, damp, excessive dust, mechanical vibrations or shocks. - In compliance with safety regulations, the device must be installed properly to ensure adequate protection from contact with electrical parts. All protective parts must be fixed in such a way as to need the aid of a tool to remove them. 2 ELECTRICAL CONNECTION N.B. - Use cables of an adequate section for the current running through them. - To reduce any electromagnetic interference connect the power cables as far away as possible from the signal cables. In model EVJ254N7VXXRXV the EVlink BLE module is integrated. PRECAUTIONS FOR ELECTRICAL CONNECTION - If using an electrical or pneumatic screwdriver, adjust the tightening torque. - If the device has been moved from a cold to a warm place, the humidity may have caused condensation to form inside. Wait about an hour before switching on the power. - Make sure that the supply voltage, electrical frequency and power are within the set limits. See the section TECHNICAL SPECIFICATIONS. - Disconnect the power supply before doing any type of maintenance. - Do not use the device as safety device. - For repairs and for further information, contact the EVCO sales network. 3 FIRST-TIME USE 1. Install following the instructions given in the section MEASUREMENTS AND INSTALLATION. 2. Power up the device and an internal test will be run. The test normally takes a few seconds, when it is finished the display will switch off. 3. Configure the device as shown in the section Setting configuration parameters. Recommended configuration parameters for first-time use. PAR. DEF. PARAMETER MIN... MAX. SP 0.0 setpoint r1... r2 P0 1 probe type 0 = PTC 1 = NTC P2 0 temperature unit of measurement 0 = °C 1 = °F d1 0 defrost type 0 = electric 1 = hot gas 2 = compressor stopped r15 1 compressor type 1 = Embraco VEM 2 = Embraco VEG 3 = Embraco VNEK e VNEU 4 = Secop VNL 50... 150 Hz (25 Hz in off) 5 = Secop 33... 133 Hz Then check that the remaining settings are appropriate; see the section CONFIGURATION PARAMETERS. 4. Disconnect the device from the mains. 5. Make the electrical connection as shown in the section ELECTRICAL CONNECTION without powering up the device. 6. For the connection in an RS-485 network connect the interface EVIF22TSX or EVIF23TSX, to activate real time functions in EVJ254N7 connect the module EVIF23TSX, for recording HACCP data in CSV format on SD card connect the module EVBD05, to use the device with the Android APP EVconnect connect the interface EVIF25TBX (or use EVJ254N7VXXRXV); see the relevant instruction sheets. If EVIF22TSX or EVIF23TSX is used, set parameter bLE to 0. 7. Power up the device. 4 USER INTERFACE AND MAIN FUNCTIONS 4.1 Switching the device on and off 1. If POF = 1 (default), touch the ON/STAND-BY key for 2s. If the device is switched on, the display will show the P5 value ("cabinet temperature" default); if the display shows an alarm code, see the section ALARMS. LED ON OFF FLASHING compressor on compressor off - compressor protection active - setpoint being set evaporator fan on evaporator fan off evaporator fan stop active cabinet light on cabinet light off cabinet light on by digital input AUX 1 auxiliary function 1 on auxiliary function 1 off - auxiliary function 1 on by digital input - auxiliary function 1 delay active AUX 2 auxiliary function 2 on auxiliary function 2 off - auxiliary function 2 on by digital input - auxiliary function 2 delay active defrost or pre-drip active - - defrost delay active - dripping active - energy saving active - low consumption active - - view time - set date, time and day of the current week view temperature - overcooling or overheating active HACCP saved HACCP alarm - new HACCP alarm saved alarm active - - If Loc = 1 (default) and 30s have elapsed without the keys being pressed, the display will show the “Loc” label and the keypad will lock automatically. 4.2 Unlock keypad Touch a key for 1s: the display will show the label “UnL”. 4.3 Set the setpoint (if r3 = 0, default) Check that the keypad isn’t locked. 1. Touch the SET key. 2. Touch the UP or DOWN key within 15s to set the value within the limits r1 and r2 (default “-40... 50”) 3. Touch the SET key (or do not operate for 15s). 4.4 Activate manual defrost (if r5 = 0, default) Check that the keypad is not locked and that overcooling is not active. 1. Touch the DEFROST key for 2s. If P3 = 1 (default), defrost is activated provided that the evaporator temperature is lower than the d2 threshold. 4.5 Cabinet light on/off (if u1c... u4c = 4) 1 Touch the CABINET LIGHT key. 4.6 Button-operated load on/off (if u1c... u4c = 9 or 10) 1. Touch the CABINET LIGHT key (for 2s if u1c... u4c = 4). If u1c... u4c = 5, the demisting switch on for the u6 duration. 4.7 Silence buzzer (if u9 = 1, default) Touch a key. If u1c... u4c = 11 and u4 = 1, the alarm output is deactivated. 5 ADDITIONAL FUNCTIONS 5.1 Activate/deactivate overcooling and overheating Check that the keypad is not locked. 1. Touch the UP key for 2s. FUNCTION CONDITION CONSEQUENCE overcooling r5 = 0 and defrost not active the setpoint becomes “setpoint - r6”, for the r7 duration overheating r5 = 1 the setpoint becomes “setpoint + r6”, for the r7 duration 5.2 Activate/deactivate energy saving in manual mode (if r5 = 0) Check that the keypad is not locked. 1. Touch the DEFROST key. The setpoint becomes “setpoint + r4”, at maximum for HE2 duration. 5.3 Activate the high or low humidity functions (if F0 = 5) Check that the keypad isn’t locked. 1. Touch the DOWN key for 1s. 2. Touch the UP or DOWN key within 15s to select the label “rH”. 3. Touch the SET key until the display shows the right label for the function (only touch the key to see the function activated). LAB. DESCRIPTION rhL low humidity function (evaporator fan with F17 and F18 if the compressor is off, on if the compressor is on)

EVJ254: Related Instructions

EPJcolor
Evco EPJcolor
05.04.2026 4 pages

EPJcolor - Interfacce utente remote IMPORTANTE Leggere attentamente questo documento prima dell’installazione, seguire tutte le avvertenze prima dell’uso de Professional operation guide for the Evco EPJcolor Recording Equipment. The manual provides technical details on service instructions, device features, operating guidelines, connectivity setup.

EV3H94
Evco EV3H94
22.06.2026 5 pages

EVCO S.p.A. | EV3H94 | Instruction sheet ver. 1.0 | Code 1043H94E104 | Page 1 of 5 | PT 05/21 EV3H94 Controller for DHW heat pump heaters EN ENGLISH - power sup Installation guide for the Evco EV3H94 Controller. This documentation explains configuration and setup instructions, firmware updates, safety precautions.

EVJ 700
Evco EVJ 700
11.08.2026 52 pages

144EVJ700E204 EVCO | 29.01.2021 | 1 EVJ 700 EVJ 700 EVJ 700 EVJ 700 Application Manual: Controller for horizontal cooking modules |||| 4 cooking combinations (d Instruction booklet for the Evco EVJ 700 Controller. It includes troubleshooting procedures and installation procedures, interface navigation, wiring diagrams.

FK 200p
Evco FK 200p
03.04.2026 2 pages

Every Control S.r.l. • FK 200P • Sheet 1/1 1 PREPARATIONS 1.1 How to install the instrument Panel mounting, panel cut out 71 x 29 mm (2.79 x 1.14 in), with Installation and maintenance guide for the Evco FK 200p Controller. This guide describes testing procedures, power management, hardware components.

EV3 HRV
Evco EV3 HRV
14.08.2026 74 pages

EVCO S.p.A. EV3 HRV & EVD HRV | Application manual ver. 1.0a | Code 1443DHRVE104 page 1 of 74 EV3 HRV & EVD HRV Controllers for mechanical ventilation units for Device setup guide for the Evco EV3 HRV Controller. It outlines maintenance guidelines and device reset instructions, warranty information, technical troubleshooting, backup procedures.

c-pro 3 micro AHU
Evco c-pro 3 micro AHU
09.06.2026 104 pages

EVCO S.p.A. c-pro 3 micro AHU/c-pro 3 kilo AHU | Application Manual ver. 1.1 | Code 144CP3UKAHE104 page 1 of 104 c-pro 3 micro AHU c-pro 3 kilo AHU PROGRAMMABL Technical reference manual for the Evco c-pro 3 micro AHU Controller. This guide elaborates on device features and maintenance procedures, maintenance, system parameters.

Similar Manuals in the Controller Category

CLIQ.mini
Clare Controls CLIQ.mini
11.07.2026 7 pages

DOC ID - 1284 • Rev 09 1 / 7 CLIQ.mini Quick Start Guide Content Introduction...1 Included and recommended tools...1 CLIQ.mini diagram...2 Installation option Complete device guide for the Clare Controls CLIQ.mini Controller. It provides guidance on system setup, internal layout, operating conditions, device operation tips.

Crouse-hinds series
Eaton Crouse-hinds series
27.04.2026 2 pages

FHF BA5113-1 05/18 Zweithörer-Set Second Ear Piece Kit Typ Typ Typ Typ 5113 5113 5113 5113 Type 5113 Type 5113 Type 5113 Type 5113 Hinweis Vor Quick start guide for the Eaton Crouse-hinds series Telephone. It provides detailed operation instructions and installation procedures, network configuration, system parameters.

Z21 WLANmaus
roco Z21 WLANmaus
18.03.2026 104 pages

WLAN-MULTIMAUS® ▶ Benutzerhandbuch ▶ User Manual ▶ Manuel d'utilisation 8010813920.indd 1 13.07.2017 10:27:31 User guide for the roco Z21 WLANmaus Remote Control. It provides information on safety and component replacement, device reset instructions, device features.

TS 971
GFA TS 971
19.05.2026 68 pages

Installation instructions Door control TS 971 Automatic control panel with radio Version: 51171521 -en- Version: i / 04.2019 0000000 0000 51171521 XXXXX Maintenance and service manual for the GFA TS 971 Controller. This documentation guides on component replacement, reset instructions, hardware setup, setup instructions.