Evikon E2638-H2S Manuals
4 pdf manual(s) Evikon E2638-H2S for free download (Document Types: Operation & user’s manual)
Evikon E2638-H2S Operation & user’s manual [PDF] (21 pages)
- Identifier: id-1997408
- Brand: Evikon
- Device: E2638-H2S Transmitter
- Type: PDF
- Key Aspects: Model Variations and Compatibility, Pre-Installation Safety Requirements, Environmental Factors and Restrictions
- UPD Date: 09.06.2026
- Source File: 2290450.pdf
- Pages: 21
- Description: Instruction manual for the Evikon E2638-H2S.
Click to expand and read text
PluraSens® Hydrogen Sulfide Detector-Transmitter E2638-H2S User Manual
Evikon E2638-H2S Operation & user’s manual [PDF] (5 pages)
- Identifier: id-1787173
- Brand: Evikon
- Device: E2638-H2S Transmitter
- Type: PDF
- Key Aspects: Recommended Spare Parts List, System Connectivity and Wiring Basics, Storage and Care Recommendations
- UPD Date: 05.05.2026
- Source File: 1753101.pdf
- Pages: 5
- Description: User support manual for the Evikon E2638-H2S.
Click to expand and read text
Nitric oxide Colourless toxic gas, relatively insoluble in water. When exposed to oxygen (including air), nitric oxide is converted into nitrogen dioxide. Chemical formula NO Molar weight 30 Relative gas density (to air) 1.03 Conversion 1 ppm = 1.23 mg/m3 Boiling point -152 °C Flammability Nonflammable, but accelerates the burning of combustible materials. Odour Pure NO is odourless, but in the air it oxidizes to NO2 which has a pungent odour Hazards Irritates respiratory tract and eyes, at high concentrations may cause lung edema and death. Exposure limits (Directive 91/322/EEC) TWA 30 mg/m3 /25 ppm IDLH (NIOSH) 123 mg/m3 /100 ppm Conversion of ppm to mg/m3 is calculated for 25°C and 1 atm. Installation guidelines (See Installation and connections section for general information.) Nitric oxide has practically the same density as air. As it is easily oxidized to form nitrogen dioxide, the sensor should be placed as close as possible to the gas source. Calibration E2608-NO detectors have been calibrated by Manufacturer with standard gas mixtures before delivery. Provided that the sensor is used under moderate conditions,the recommended interval for field recalibration is 6 months. Please contact your dealer for more information. Maintenance Do not perform any maintenance operation with the power on. Clean the device with soft damp cloth. Do not use any abrasive cleaning agents. Do not immerse the device into water or any cleaning media. Delivery set –Detector-transmitter E2608 (wall mount or duct mount version) – Mounting accessories: 4 cross-shaped mounting lug with screws and 4 screws with plastic dowels for wall mount version rubber flange for duct mount version fixing clamp for remote probe versions E2608-NO_UM_EN Rev 06.06.2020 Specifications Sensor type electrochemical cell Sampling method diffusion Typical detection range 0...250 ppm Maximum overload 1000 ppm Resolution / digital unit 1 ppm Response time T90 < 40 s Sensor lifetime > 12 months Calibration interval 6 months Signal update every 1 second Power supply options 11...30 VDC, 24 VAC or 90...265 VAC (with mains power unit) Power consumption < 2 VA Load resistance RL < (Us - 2 V) / 22 mA for 4-20 mA RL > 250 kOhm for 0-10 V mode Digital interface RS485, Modbus RTU protocol no galvanic isolation Analog outputs 2 × 4-20 mA / 0-10 V, user settable Outputs assignment OUT1 2 gas; OUT2 2 gas Output scale width > 10 × resolution Recommended: 20-100% of the detection range Relay otputs 2 × SPST, max 5 A, 30 VDC / 250 VAC Default alarm setpoints RE1 (LOW): set 10 ppm, release 8 ppm RE2 (HIGH):set 25 ppm, release 20 ppm Cable connections screwless spring loaded terminals Enclosure grey ABS, wall mount, protection class IP65 Dimensions H85 × W82 × D55 mm CE marking according to 2014/30/EU and EN61326-1 requirements Operating conditions -30...50 °C, 15...90% RH non-condensing, 0,9...1,1 atm explosion safe indoor areas, non-aggressive atmosphere NOTE The sensor may exhibit considerable sensitivity to hydrogen sulfide and nitrogenr dioxide Warranty This product is warranted to be free from defects in material and workmanship for a period of one year from the date of original sale. During this warranty period Manufacturer will, at its option, either repair or replace product that proves to be defective. This warranty is void if the product has been operated in conditions outside ranges specified by Manufacturer or damaged by customer error or negligence or if there has been an unauthorised modification. Evikon MCI OÜ Teaduspargi 7/9, Tartu [email protected] Tel. +372 733 6310 50411 Estonia www.evikon.eu PluraSens® Nitric Oxide Detector-Transmitter E2608-NO User Manual
Evikon E2638-H2S Operation & user’s manual [PDF] (39 pages)
- Identifier: id-1844780
- Brand: Evikon
- Device: E2638-H2S Transmitter
- Type: PDF
- Key Aspects: Unpacking and Inspection Guidelines, Efficiency and Calibration Tips, Product Performance Metrics
- UPD Date: 24.03.2026
- Source File: 1877983.pdf
- Pages: 39
- Description: Owner’s guide for the Evikon E2638-H2S.
Click to expand and read text
PluraSens® Solvent Vapor Detector-Transmitter E2638-PID User Manual
Evikon E2638-H2S Operation & user’s manual [PDF] (20 pages)
- Identifier: id-1997422
- Brand: Evikon
- Device: E2638-H2S Transmitter
- Type: PDF
- Key Aspects: Troubleshooting Information, Risk Mitigation and Accident Prevention, Common Issue Diagnostic Flows
- UPD Date: 25.07.2026
- Source File: 2290436.pdf
- Pages: 20
- Description: Product documentation for the Evikon E2638-H2S.
Click to expand and read text
PluraSens® Hydrogen Sulfide Detector-Transmitter E2638-H2S User Manual
E2638-H2S: Related Instructions
PluraSens® Sulfur Dioxide Detector-Transmitter E2648-SO2 User Manual User reference guide for the Evikon E2648 Series Gas Detectors. This manual describes setup, usage, and user instructions, connectivity setup, product safety.
PluraSens® Carbon Dioxide Detector-Transmitter E2638-CO2 User Manual Setup and usage guide for the Evikon PluraSens E2638-CO2 Security Sensors. The documentation guides users through setup and device calibration, testing procedures, setup instructions.
PluraSens® Low differential pressure transmitter E2418DP User Manual Service and user manual for the Evikon PluraSens E2418DP Transmitter. It explains installation, setup, and interface navigation, usage recommendations, device calibration.
PluraSens® Ozone Detector-Transmitter E2608-O3 User Manual Essential instructions for the Evikon PluraSens E2608 Series Gas Detectors. This reference includes hardware instructions, user preferences, technical assistance.
PluraSens® Ethylene Transmitter E2618-C2H4 User Manual User operation guide for the Evikon PluraSens E2618-C2H4 Transmitter. The manual describes backup procedures, operational safety, application scenarios, basic operation.
PluraSens® Refrigerant Detector-Transmitter E2648-HFC User Manual Reference manual for the Evikon PluraSens E2648-HFC Transmitter. It describes maintenance tasks and interface navigation, technical specifications, assembly reference, safety precautions.
Similar Manuals in the Transmitter Category
1 all-guides com Device technical manual for the LINK-MI LM-WHD10 Series Transmitter. The manual guides users through warranty information, maintenance, wiring setup.
Emergency Locator Transmitters DOC06006D Ref. 0141922D TP PAGE : 1 Date of rev. FEB 01/2008 Revision 03 First issue: FEB 01/2007 INSTALLATION MANUAL OPERATION M User instruction manual for the Kannad 406 AF-COMPACT Transmitter. It provides information on safety and system checks, troubleshooting, repair references, support details.
CROUSE-HINDS SERIES Explosionsgeschützte Leergehäuse GBXE Explosion-protected empty enclosure GBXE Boîtier vide GBXE pour atmosphères explosives Betriebsanl User and installation guide for the Eaton CROUSE-HINDS GBXE Enclosure. This manual offers stepwise instructions for adjustment procedures, system checks, device features.
User support guide for the Siemens SITRANS P DS III Transmitter. The manual outlines technical specifications and operating modes, system checks, device instructions.