Faraday 8705 Manuals

1 pdf manual(s) Faraday 8705 for free download (Document Types: Installation instructions and wiring)

Faraday 8705 Installation instructions and wiring Thumbnail

Faraday 8705 Installation instructions and wiring [PDF] (4 pages)

  • Identifier: id-1448640
  • Brand: Faraday
  • Device: Faraday 8705 Control Unit
  • Type: Installation instructions and wiring, PDF
  • Key Aspects: Step-by-Step Assembly Procedures, Recommended Spare Parts List, Hardware Verification Checklists
  • UPD Date: 13.05.2026
  • Source File: 1549802.pdf
  • Pages: 4
  • Description: Device operation guide for the Faraday 8705.
Pages Preview:
  • Faraday 8705 Installation instructions and wiring preview - page 2
  • Faraday 8705 Installation instructions and wiring preview - page 3
  • Faraday 8705 Installation instructions and wiring preview - page 4
Document Preview & Text Transcription (Main Page)
Click to expand and read text
PAGE 1 OF 4 P/N 315-034850FA-7 INTRODUCTION The 8705 Conventional Zone Module interfaces an Initiating Device Circuit of conventional devices to an Addressable Device Circuit of an MPC-6000 or MPC-7000 Control Unit. The 8705 can power up to thirty compatible 2-wire, ionization or photoelectric smoke detectors. It can also monitor an unlimited number of contact devices such as waterflow switches, thermal detectors, manual stations, etc. The 8705 may be programmed for alarm verify operation. A Status LED, visible through the cover plate, indicates the condition of the circuit. This multicolor LED displays red for alarm, yellow for trouble, and green for normal operation. The 8705 supports Style D (Class A) and Style B (Class B) wiring. Each module uses one address on the Address- able Device Circuit. It does not require any mechanical address programming. Use the 8720 Programmer/Tester to program and test the module. PROGRAMMING To prevent damage to the 8720, do not connect modules to the 8720 until the Addressable Device Circuit wiring is disconnected. Only one device must be connected to the 8720 at a time. 1. Plug the programming cable of the Faraday 8720 Programmer/Tester into the two-pin receptacle on the module. 2. Set the address for the module by following the instructions in the 8720 Programmer/Tester Manual, P/N 315- 033260FA. 3. Record the device address on the label located on the module. The module can now be installed and wired to the system. MOUNTING The 8705 must be installed in a UL Listed electrical box. 1. Mount the 8705 in a standard two gang electrical box. The box must have a depth of at least 3½ inches. 2. When the field wiring for the initiating devices, device loop, and 24 VDC is connected, press the 8705 into the box and fasten it with the four screws provided. 3. Attach a dress bezel if necessary, making sure that the ALARM LED is aligned with the hole in the bezel. INSTALLATION INSTRUCTIONS AND WIRING FOR CONVENTIONAL ZONE MODULE P/N 8705 Siemens Industry, Inc. Building Technologies Division • Florham Park, NJ Tel: (973) 593-2600 • Fax: (973) 593-6670 Web: www.faradayfirealarms.com 8705 8705 FRONT BACK SIDE ALARM 1 2 3 4 5 6 7 8 9 PROGRAMMING POINTS Figure 1 8705 Module

Similar Manuals in the Control Unit Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Viessmann VITOTRONIC 100

Manual: Viessmann VITOTRONIC 100 (7CZ63R, Upd.13-08-2026)

36 506 76 13-08-2026 view all manuals
Beast-Tek Instruments PIXEL DRUM v1.3

Beast-Tek Instruments Control Unit Build manual (File: PDF, 20-05-2026)

35 234 36 20-05-2026 view all manuals
Flowserve Valtek Mark Two

Valtek Mark Two User instructions - 92398R

16 123 30 26-08-2026 view all manuals
Infineon AIROC CYBLE-343072-02

#LOKKCN: AIROC CYBLE-343072-02 Control Unit Manual 

58 629 95 07-08-2026 view all manuals
Microchip Technology BM62

#O8D7Y1: BM62 Control Unit Manual 

75 1257 189 17-08-2026 view all manuals
oventrop Multidis SF

Multidis SF (Plumbing Product ePDF Manual, #4942J8)

40 819 205 15-07-2026 view all manuals