Ferm FCD-2400 Manuals

1 pdf manual(s) Ferm FCD-2400 for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

Ferm • P.O. Box 134 • 8280 AC Genemuiden • NL • www.ferm.com 0306-03 Ferm Combidrill with Impact function FCD-2400 I 2 USER’S MANUAL Art.nr. 718790 Screwfix art.nr 19323 UK Subject to change Document Ref: FCD240012/19323/PMR6/issue 1/Mar 02 Copyright © These instructions are the sole property of Ferm-Omega Tools and may not be reproduced Ferm 7 FERM COMBIDRILL FCD-2400 1 2 USERS MANUAL TECHNICAL SPECIFICATIONS PACKAGE CONTENTS 1 Cordless drill 2 Batteries 1 Battery charger 2 Double sided bits 1 Case 1 Users manual 1 Safety instructions 1 Guarantee card Check the machine, loose parts and accessories for transport damage. PRODUCT INFORMATION 1 Direction switch 2 On/off switch 3 Torque setting ring 4 Impact sleeve 5 Chuck 6 Battery SAFETY INSTRUCTIONS The following pictograms are used in these instructions for use: Denotes risk of personal injury, loss of life or damage to the tool in case of non-observance of the instructions in this manual. Denotes risk of electric shock. Carefully read this manual before using the machine. Make sure that you know how the machine functions and how to operate it. Maintain the machine in accordance with the instructions to make sure it functions properly. Keep this manual and the enclosed documentation with the machine. Ferm products are manufactured to high quality standards they are safe and fit for purpose at time of sale, but all tools can be dangerous if the correct precautions are not taken. Always follow these instructions, do not carry out the ope- ration until you are sure you can do so in safety. Remember to consider the work environment for safe operation as well as safety for tool use. Warning! When using electric tools, basic safety precautions should always be followed to reduce the risk of fire, electric shock and personal injury. Read all these instructions before attempting to operate this product. Save these instructions for future reference. PERSONAL SAFETY Use Personal Protection Safety Equipment Protect eyes with safety glasses or goggles note: the use of safety protective eyewear without the CE mark can lead to serious injury if the lens breaks. A suitable dust mask should be worn if cutting; drilling or sanding is dusty, in particular chipboard or MDF. Approved safety footwear and headgear should worn as appropriate, for example on building works or when heavy weights are involved. Wear a suitable apron to protect against sparks/debris. Wear earplugs or ear defenders. Dress properly Do not wear loose clothing or jewellery. It can get caught in moving parts. Non-skid footwear is recommended when working out doors. Wear protective hair covering to contain long hair Stay alert Watch what you are doing Use common sense. Do not operate tools when tired or after taking alcohol or pre- scription/ non-prescription drugs. 2 3 4 5 1 1 2 3 4 5 6 Voltage | 24 V Voltage battery charger | 230 V~ Frequency battery charger | 50 Hz Capacity battery | 1.2 Ah (NiCd) Charging time | 1 h Speed, no load | 0 - 900/min Impact frequency | 0 - 16200/min Machine weight (incl. 1 battery) | 2.5 kg Lpa Sound pressure level | 91.3 dB(A) Lwa Sound power level | 104.3 dB(A) Vibration | 7 m/s2 2 Ferm EXPLODED VIEW SPARE PARTS LIST FCD-2400 I 2 REF NR. DESCRIPTION FERM NR. 3 SWITCH 406654 4 FCD-2400 I B BATTERY 718791 11 DRILL CHUCK 406516 12 LEFT BOLT DRILL CHUCK 406403 29 LEFT / RIGHT BUTTON 406656 - CHARGER FCD-2400 I C 406517 ELECTRICAL INFORMATION This product is complete with a pre-wired mains plug, it is double insulated in accordance with EN 60335 – no earth wire is required If the plug needs replacing follow these instructions. Wire correctly The wires in the mains lead are coloured in the following way: BLUE -Neutral BROWN -Live Securing wires Secure wires carefully and firmly to the correct termi- nals. Secure the mains cable in the plug cord grip firmly Fit a 5-amp fuse. If a 13amp (BS1363) plug is used a (BS 1362) ASTA approved 5-amp fuse must be fitted. Recycle/Dispose of old plug and cable Prevent inadvertent connection to socket and risk of electric shock. If in doubt always consult a Qualified Elec- trician. ENVIRONMENT Recycle the packaging according to the identification marks on it. At the end of the product or its accessories life please recycle where facilities exist. NiCd batteries are recyclable, take them to a local recy- cling station or phone the Helpline for current advice on recycling. Helpline For any questions relating to operational or safety matters contact: Ferm Customer Helpline on: 0115 966 1199 Monday-Friday 8am – 6pm Saturday 9am – 1 pm GUARANTEE The guarantee conditions can be found on the separately enclosed guarantee card. We declare under our sole responsibility that this product is in conformity with the following standards or standardized documents prEN50260-1, prEN50260-2-1, prEN50260-2-2, EN60335-1, EN60335-2-29, EN55014-1, EN55014-2, EN61000-3-2, EN61000-3-3. in accordance with the regulations. 98/37/EEC, 73/23/EEC, 89/336/EEC from 01-12-2000 GENEMUIDEN NL G.M. Ensing Quality department CEı DECLARATION OF CONFORMITY (UK) Blue (Neutral) Green & Yellow (Earth) Brown (Live) Fuse (13 Amp) 6 Ferm OPERATIONAL SAFETY Warning! The battery is normally sealed but in event of the battery being damaged be aware that it contains acid, if you get any on your skin or in your eyes wash the affected parts with water immediately and seek medical advice as soon as possible. Warning! Do not short circuit the battery it will cause it to overheat, catch fire or even explode. To avoid this happening: Do not connect wires to the terminals of the battery. Do not expose the battery or drill to water, rain or damp atmospheres. Ensure that no metal objects (coins, nails etc) are caught in the battery housing or battery socket in the drill. Do not throw or dispose of the battery into water or fire. Concentrate Routine and repetition can lead to mistakes. Remember that a slight lack of concentration can result in serious injuries in a split second. Keep work area clean Cluttered areas and benches invite injuries. Consider the work environment Do not expose power tools to rain or use them in damp or wet locations. Keep work area well lit. Do not use power tools in the presence of flammable liquids, vapours or gases. Guard against electric shock This unit and its charger contain dangerous voltages. Use a RCD (residual current device) to provide protection against electrical shock. Prevent body contact with grounded surfaces (e.g. pipes, radiator, ranges or refrige- rators). Keep children and pets away Do not let children or pets come into contact with the tool, extension cable or work area. Do not force the tool It will work better and safer at the rate for which it was intended. Use the right tool Do not force small tools or attachments to do the job of a heavy-duty tool. Do not use tools for purposes for which they were not intended; for example do not use a circular saw for cutting trees or logs. Do not abuse cable Never carry the tool by the cable or pull it to disconnect it from the power socket. Keep the cable away from heat, oil and sharp edges. Do not touch the metal plug pins when connecting or removing the plug. Secure Work Use clamps or a vice to hold work. It is safer than using your hand and it frees both hands to operate the tool Do not over-reach Keep a proper footing and balance at all times. Disconnect tools from power supply When not in use, before servicing and when changing accessories such as blades, bits and cutters. Always remove the battery and set the direction switch to lock position. Always switch off and unplug from the power supply before making adjustments or inserting batteries into charger unit. Remove adjusting keys and wrenches Ensure that they are removed from the tool before swit- ching on. Avoid unintentional starting Do not carry plugged in tools with your finger on the switch. Check that the switch is off before plugging in to socket. Extension cables Use only three core earthed extension cables suitable for the power input of the tool (minimum cable size 1.5mm2). Plug into an earthed socket only. When using a cable reel unwind it fully. Do not use long extension cables. Outdoors use If the tool is suitable to be used outdoors, only use an extension cable intended for outdoor use and marked accordingly. Use a RCD (residual current device) to pro- vide protection against electrical shock. Do not use in rain or damp conditions. Connect a dust extraction device Whenever there are facilities for fitting a dust or fume extraction system, make sure it is connected and used. Use recommended accessories The use of any other accessory or attachment other than recommended in the instructions or catalogue may pre- sent a risk of personal injury. Warning! Before using this drill check carefully for hazards, for example when drilling walls make sure you do not contact with electrical wires, water pipes or asbe- stos. If asbestos is present, cease operations and contact your local council for advice. Ferm 3