Fluke 2680A-RF24G 120 Manuals
1 pdf manual(s) Fluke 2680A-RF24G 120 for free download (Document Types: Instruction sheet)
Fluke 2680A-RF24G 120 Instruction sheet [PDF] (4 pages)
- Identifier: id-1112174
- Brand: Fluke
- Device: 2680A-RF24G 120 Wireless Access Point
- Type: PDF
- Key Aspects: End-of-Life Handling and Disposal, Performance Optimization Tips, Information on Regular Maintenance
- UPD Date: 26.08.2026
- Source File: 1046223.pdf
- Pages: 4
- Description: User instructions for the Fluke 2680A-RF24G 120.
Click to expand and read text
® PN 2558823 November 2005 ©2005 Fluke Corporation. All rights reserved. Printed in U.S.A. 1 2680A-RF24G 120 / 230 Wireless Network Bridge Instruction Sheet Introduction The 2680A-RF24G 120 or 230 Wireless Network Bridge (hereafter referred to as “the Wireless Bridge”) is a wireless network device that creates a wireless link between Fluke 2680 Series or NetDAQ models and a computer (PC) running Fluke DAQ or NetDAQ Logger application software. Note The Wireless Bridge operates in the 2.4 GHz frequency range using the WiFi Wireless-G or IEEE-802.11g standard supported internationally. However, when operating outside the United States, check with the appropriate governing agency in the host country prior to Wireless Bridge operation. This instruction sheet assumes familiarity with the Fluke DAQ or NetDAQ Logger software and 2680 Series or NetDAQ model operation. If unfamiliar with Fluke DAQ or NetDAQ Logger software or the 2680 Series or NetDAQ models, refer to the software user documentation or the 2680 Series or NetDAQ users manuals. Figure 1 shows the Wireless Bridge. Antenna Power Connection LAN Port Reset efff01.eps Figure 1. 2680A-RF24G 120 / 230 Wireless Bridge Contacting Fluke To locate an authorized service center, visit us on the World Wide Web at www.fluke.com or call Fluke using any of the following numbers: USA: 1-888-99-FLUKE (1-888-993-5853) Canada: 1-800-36-FLUKE (1-800-363-5853) Europe: +31 402-678-200 Japan: +81-3-3434-0181 Singapore: +65-738-5655 Anywhere in the world: +1-425-446-5500 Shipping Contents The Wireless Bridge comes with the following items: • Instructions for use with Fluke DAQ or NetDAQ Logger software (this sheet) • Quick Installation Guide • CD-ROM with set up software and documentation • Antenna • 1 meter Ethernet network patch cable • AC power adapter • Stand feet/wall-mount-accessory kit • Universal AC adapter (230 only) Requirements A PC with Ethernet port or network connection and Windows XP, 2000, or 98 SE plus a CD-ROM drive is required to set up the Wireless Bridge. In operation, no Windows drivers or software is required for the Wireless Bridge: it connects directly to an Ethernet port on either a network device or a LAN. Installation There are two ways to use the Wireless Bridge – either as part of an “Ad-Hoc” wireless network, or in “Infrastructure” mode. • “Ad-Hoc” is typically used for an isolated network of 2680 Series or NetDAQ models. In
2680A-RF24G 120: Related Instructions
TM OneTouch Series II Network Assistant Users Manual September 1999 Rev. 1, 11/00 © 1999, 2000 Fluke Corporation. All rights reserved. Printed in USA All produ User and installation guide for the Fluke Series II Network Card. This guide includes device overview, installation support, network setup, configuration options.
Victoreen® 05-437 Primalert® 35 Area Radiation Monitor Operators Manual March 2005 Manual No. 126011 Rev. 3 ©2003, 2005 Fluke Corporation, All rights reserv Advanced user guide for the Fluke Victoreen 05-437 Operators Monitor. The document explains service contacts, startup procedures, energy usage, reset instructions.
QuickStart: Fluke TiX-640, TiX-660, TiX-1000 © 2013 The Snell Group / 322 N. Main St. / Suite 8 / Barre, VT 05641 / 800.636.9820 / www.thesnellgroup.com Fluke General instruction manual for the Fluke tix640 Thermal cameras. The document highlights operating procedures and product safety, technical guidelines, device calibration, operation.
® 725Ex Multifunction Process Calibrator Calibration Manual PN 2406553 January 2005 Rev. 1, 5/09 © 2005, 2009 Fluke Corporation. All rights reserved. Printed Comprehensive guide for the Fluke 725Ex Test Equipment. It outlines installation and maintenance schedule, firmware installation, connectivity setup.
PN 2142235 April 2004, Rev. 4 4/10 ©2004-2010 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective comp User operation guide for the Fluke DTX-MFM2 Control Unit. It details safety instructions and operating guidelines, device reset instructions, technical specifications.
© 2008 DH Instruments, a Fluke Company GB-H-152-70M and GB-H-152-100M Gas Booster Packages Operation and Maintenance Manual Product usage manual for the Fluke GB-H-152-100M Other. It contains information on setup guidelines, installation support, product maintenance.
Similar Manuals in the Wireless Access Point Category
How To Set Up Wireless Network Security Part 1: WEP Part 2: WPA-PSK Part 3-1: RADIUS Server Installation Part 3-2: 802.1x-TLS Part 3-3: WPA You can secure your Step-by-step guide for the D-Link DWL-2000AP - AirPlus Xtreme G Wireless Access Point. This documentation covers operating modes, product maintenance, connectivity setup.
– 1 – Quick Start Guide 1. Unpack the AP ◆ Spark AC Wave2 Mini, SP-W2M-AC1200 ◆ Universal AC/DC power adapter ◆ USB cable — Micro to Type A ◆ Ca Official installation manual for the IgniteNet Spark SP-W2M-AC1200 Wireless Access Point. It offers guidance on safety information, operational procedures, service procedures.
LevelOne WAP-6002 150Mbps N Wireless Access Point User Manual V1.2.0 Instruction and reference manual for the LevelOne WAP-6002 Wireless Access Point. This reference manual outlines control functions, wiring setup, startup procedures, dimensions and layout.
NanoStation loco Zip Tie Package Contents Installation Requirements Shielded Category 5 (or above) cabling with drain wire should be used for all outdoor wired Full user manual for the Ubiquiti Loco5AC Wireless Access Point. This manual explains supported accessories, performance details, application scenarios.