FORENSICS DETECTORS FD-4A Manuals

1 pdf manual(s) FORENSICS DETECTORS FD-4A for free download (Document Types: Manual )

FORENSICS DETECTORS FD-4A Manual  Main Page Preview

Manual  [PDF] (12 pages)

  • Updated: 23.04.2026

Document Preview & Text Transcription

BASIC RESIDENTIAL COMBUSTION ANALYZER FORENSICS DETECTORS TM FORENSICS DETECTORS TM www.forensicsdetectors.com 1 BASIC RESIDENTIAL COMBUSTION ANALYZER Model: FD-4A CONFIGURATION & COMPONENTS INCLUDED Serial #: CO Sensor O2 Sensor Detector 4A Pump NOx Filter Water Trap + Magnet Hose Assembly Calibration Cap Cap Screw Stainless Probe Hard Carry Case 110V Wall Charger Charger USB Cable Magnet Attachment QC/CAL Certificate User Manual Other BASIC RESIDENTIAL COMBUSTION ANALYZER FORENSICS DETECTORS TM FORENSICS DETECTORS TM www.forensicsdetectors.com 2 PRODUCT FEATURES • Measures CO (ppm) & O2 (%) • Calculates COAF (air free) & EA (excess air) • Comes with a Water Trap, Particle & NOx filters • For residential combustion AND / OR ambient applications • Strong magnet for easy mount on appliances • Rechargeable Lithium-ion battery via easy USB charger • Professional aluminum hard-case • Electronic Pump with Stainless Steel Probe PRODUCT COMPONENTS 1. Analyzer - CO & O2 sensors with a niobium magnet for mounting. 2. Electronic Pump with Stainless Probe. 3. Hose assembly. 3 feet of silicone tubing, Water trap, particle and NOx filters with sensor cap. The NOx filter removes cross-interfering acid gases to minimize CO sensor interference. 4. Aluminum Hard-case 5. Screw to mount sensor cap to the Analyzer 6. USB Charging cable 7. USB Charger 8. Analyzer and Pump Aluminum Case 9. Calibration Certificate 10. Manual (this document) USER TIPS - Ensure the analyzer and pump are stored well within specifications. - When using the analyzer, condensation may occur and the water trap will slowly fill with water. Keep track of this. Empty as necessary. Always empty before storing and retiring the unit after working. Some condensation may occur in the electronic pump. Run the pump with fresh air to ensure condensation within the pump has been removed. - The NOx filter will last for the life of the detector. - The sensors have a rated life of 2 years. If well taken care of, they can last longer (up to 3 years) but will require more frequent calibration. - Please email FORENSICS DETECTORS if any part requires replacement. - FORENSICS DETECTORS does not offer sensor replacement. Given the price point of the detector and cost of the sensor parts, shipping and calibration, it is simply not economically viable to allow for customer sensor replacement – and easier to replace the detector. Both pump and detector can be separately purchased, email us. - If unsure, always ask. Email us: [email protected] BASIC RESIDENTIAL COMBUSTION ANALYZER FORENSICS DETECTORS TM FORENSICS DETECTORS TM www.forensicsdetectors.com 3 1. INTRODUCTION You have purchased the BASIC RESIDENTIAL COMBUSTION ANALYZER by FORENSICS DETECTORS. The detector is factory calibrated. This product is a BASIC analyzer - no frills, simple use, designed to simply get the job done with no messing around. Turn ON and GO. This detector is made with a robust design using high quality electrochemical sensors made in the UK. This detector was made for RESIDENTIAL use for HVAC technicians, contractors, engineers, energy inspectors, plumbers and others that need to analyze combustion and flue gases (from natural gas or propane). In addition, the detector can be used as an ambient air quality detector. The analyzer contains both CO and O2 sensors. The analyzer calculates COAF (CO Air Free) and Excess Air (EA) only when O2 is less than 20%. COAF & EA equations are calculated as follows: COAF = (COmeasured x 20.9) / (20.9 - 02measured) EA% = [[20.9/ (20.9 - 02measured)] – 1] x 100 2. QUICK SETUP 1. Ensure all components included. 2. Ensure analyzer/pump are fully charged. 3. Connect silicon tube with bottom of pump (pump outlet). Connect pump probe. Attached sensor cap on the analyzer with screw. 4. Double check all tubing is well connected and in place. 5. Check water trap, ensure it is empty of water, if not, open and dry it out. 6. Turn ON pump and detector. When ready to sample press the ON/OFF button on the pump and gas will be drawn from the probe point. 7. Read this manual and familiarize yourself with the operation of the devices & components. 8. Follow best practices when selecting combustion gas sample location for residential appliances. Follow local codes and appliance manufacturer instructions. BASIC RESIDENTIAL COMBUSTION ANALYZER FORENSICS DETECTORS TM FORENSICS DETECTORS TM www.forensicsdetectors.com 4 3. SPECIFICATIONS ANALYZER SPECIFICATIONS Warranty: 1 year limited warranty Sensor: Electrochemical Sensor CO & O2 Calculated COAF: CO Air Free (COAF) only when O2 < 20% Calculated EA: Excess Air (EA) only when O2 < 20% Sensor CO & O2 Life: 2 years Detection Range: CO (0-1000ppm), O2 (0-30%vol) Error: <±5% of reading Response Time: <60 seconds Storage/Operating Temp: 0-122F Storage/Operating Humidity: <95%RH Battery: DC3.7V Li–Ion battery 2000mAh Operation Time: >12 hours Dimension/Weight: 5 x 2.7 x 1.7 inches, 230grams (7.8 oz.) Rating: ATEX certified EXiaIICT4. IP65 certified. PUMP SPECIFICATIONS Warranty: 1 year limited warranty Storage / Operating Temp: 32°F - 140°F Storage / Operating Humidity: <95%RH Operating voltage: DC3.7V Li battery 1500mAh Flow rate: 0.5 LPM, 500 cc/min Weight: 186g (6.6 oz.) Probe Length: 8 inches Pump Device: 9 x 2.5 x 1 inches Noise: <60dB CARRY CASE SPECIFICATIONS Weight: 700g (2lb and 6 oz.) Dimension: 11 x 7 x 3 inches