Digital Timer MENU RST PROG AUTO ON OFF AM PM OK RCL / DST MO TU WE TH FR SA SU CTD RND +1h18 88 88:88 Press to clear all settings In clock mode, press to turn on/off DST In programming mode press to clear current program setting Press and hold to program clock In programming mode, press to confirm selected settings Press to begin programming press to exit to clock mode In programming mode, press to adjust hour and minutes In clock mode, press to change timer mode (ON, Auto ON, OFF, Auto OFF) In programming mode press to adjust hour and minutes Install Set Up 1. If the time screen is completely blank it will need to be plugged into an outlet and charged for four hours before programming can begin. If the screen is displaying numbers, it can be programmed and plugged into the wall afterwards. 2. Before programming, all settings should be reset. The reset button is located just below the “RCL/ DST” button and is identified by “RST”. Use a toothpick or ball point pen to push the “RST” button. Once pushed the screen will show the display below on the screen. See Diagram A Diagram A Diagram B NOTE – Timer will automatically exit the setting mode and return to normal clock mode if no buttons are pressed for 20 seconds. Any settings made previously will be saved. Current Time Setting 1. Press and hold “OK” for two seconds to set current time. 2. Press the + or – buttons to set the hour, taking note of the AM or PM in the top left corner of the screen. Press OK to confirm. 3. Press the + or – buttons to set the minutes. Press “OK” to confirm. 4. Press “MENU” to exit the current time setting. Programming the On/Off Times 1. In clock mode, press “MENU” to program on/off times 2. 1 ON --:-- should be the first setting. There are a total of 2 On/Off settings. 3. Press “OK” to program 1 ON. 4. Press the + or – buttons to set the hour. Press “OK” to confirm. 5. Press the + or – buttons to set the minutes. Press “OK” to confirm. 6. Press the + button to move to 1 OFF programming. 7. Repeat steps 3 through 5 to program the other On/Off setting. 8. Press “MENU” to complete the current On/Off program setting. RCL (Clear Buttons) Setting 1. Press the “OK” button to select the On/Off setting that needs to be changed 2. Press the “RCL/DST” button to reset the current On/Off setting. Switch Mode Indication The actual mode is shown in the display as “ON”, “AUTO ON”, “OFF”, or “AUTO OFF” together with the time of day. In normal clock mode, use the + button to adjust this to the desired setting. This can be used to override the timer as explained in Diagram C. Diagram C ON = Always ON OFF = Always OFF; AUTO ON = Timer is activated and lamp/device is on. The timer will follow the next off program. AUTO OFF = Timer is activated and lamp/device is off. The timer will follow the next on program. Summer Time Feature (DST) Note: DST stands for Daylight Savings Time. DST is either “ON” or “OFF”. 1. Push the “RCL/DST” button to advance the current time 1 hour to reflect Daylight Savings Time. The “+1h” icon will appear in the lower left corner of the display. 2. Pushing the “RCL/DST” button will decrease the time by 1 hour and the “+1h” icon will disappear. Power Back-Up In the event of a power failure, the timer will retain its settings. This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. FCC NOTE: The manufacturer is not responsible for any radio or TV interference caused by unauthorized modifications to this equipment. Such modifications could void the user’s authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encour- age to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme á la norme NMB-003 du Canada PROG AUTO ON OFF AM PM MO TU WE TH FR SA SU CTD RND +1h18 88 88:88 AUTO OFF ON AUTO ON OFF 15430 Manual Version 1 11/02/2011 PROG AUTO OFF AM Problem Light or appliance does not turn ON. Light turns ON/OFF at day instead of night. Timer is resetting time or program. Solution Make sure light/appliance power switch is in ON position. Make sure timer is in AUTO mode. If timer is in OFF mode the program is not running. Check to make sure AM/PM time and program settings are correct. Timer is being used on a motor or transformer load. It is not recommended for this use. Troubleshooting After a few seconds http://waterheatertimer.org/plug-in-timers.html#15430
GE 15430: Timer Category Related Instructions
Questions?, ¿Preguntas? 201.661.9944 ©2010 AmerTac™ 250 Boulder Drive Breinigsville, PA 18031 www.amertac.com Made in China Fabriqué en Chine/Hecho en China I10-0001-B TMDW30 Indoor Digital Wall Switch Timer Instruction Manual & Warranty - Wire in accorda User support guide for the WESTEK TMDW30 Timer. This manual outlines installation, application scenarios, safety features, performance optimization.
Technical operations guide for the Emerson Research SmartSet JMK2442 Timer. This guide elaborates on device features and hardware components, setup guidelines, technical specifications.
Practical operating guide for the Orbit 57096 Lawn and Garden Equipment. This documentation outlines installation, operating modes, connectivity setup, firmware updates.
House Control with LOGO! 8 and Weather Sensors LOGO! 8, KTP400 Set 11 https://support.industry.siemens.com/cs/ww/en/view/68585346 Siemens Industry Online Support Official operating instructions for the Siemens SIMATIC HMI KTP400 Basic Control Systems. It contains information on support details, component replacement, installation guides.