GE Appliances Zoneline 2800 Manuals

4 pdf manual(s) GE Appliances Zoneline 2800 for free download (Document Types: Owner's manual and installation instructions, Data manual)

Document Preview & Text Transcription

TINSEA471JBRZ 49-7536 12-05 JR Air Conditioners Safety Instructions . . . . . . . . . . .2 Operating Instructions Air Direction . . . . . . . . . . . . . . . .4 Auxiliary Controls . . . . . . . . . .5–9 Controls . . . . . . . . . . . . . . . . . . . .3 To Remove the Room Cabinet . .4 Vent Control . . . . . . . . . . . . . . . .4 Care and Cleaning Air Filters . . . . . . . . . . . . . . . . . .11 Base Pan . . . . . . . . . . . . . . . . . .10 Outdoor Coils . . . . . . . . . . . . . .10 Room Cabinet and Case . . . . . .10 Vent Filter . . . . . . . . . . . . . . . . .10 Installation Instructions Electrical Supply . . . . . . . . .14–17 Installing the Zoneline . . . .18, 19 Optional Drain Kit . . . . . . . . . .20 Preparation . . . . . . . . . . . . . . . .12 Replacing an Existing Unit? . . .13 Troubleshooting Tips . . . .21, 22 Normal Operating Sounds . . . .23 Consumer Support Consumer Support . . .Back Cover Product Registration . . . . . .25, 26 Warranty . . . . . . . . . . . . . . . . . .27 Heat/Cool Model 2800 Heat Pump Model 3800 Owner’s Manual and Installation Instructions ge.com Write the model and serial numbers here: Model # ____________________ Serial # ____________________ Find these numbers on a label behind the room cabinet on the base pan. Zoneline ® Español For a Spanish version of this manual, visit our Website at ge.com. Para consultar una version en español de este manual de instrucciones, visite nuestro sitio de internet www.GEAppliances.com. Française For a French version of this manual, visit our Website at www.GEAppliances.com. Pour une version française de ce manuel d’utilisation, veuillez visiter notre site web à l’adresse www.GEAppliances.com. Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. I This Zoneline must be properly installed in accordance with the Installation Instructions before it is used. See the Installation Instructions in the back of this manual. I Replace immediately all electric service cords that have become frayed or otherwise damaged. A damaged power supply cord must be replaced with a new power supply cord obtained from the manufacturer and not repaired. Do not use a cord that shows cracks or abrasion damage along its length or at either the plug or connector end. I Unplug or disconnect the Zoneline at the fuse box or circuit breaker before making any repairs. NOTE: We strongly recommend that any servicing be performed by a qualified individual. Replacing an existing unit? For details, see the Installation Instructions in this manual. SAFETY PRECAUTIONS READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY. SAVE THESE INSTRUCTIONS 2 Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support 3 Controls Temp Control The temp control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same comfort level. When you turn the knob to COOLER (blue), the indoor air will become cooler. Turn the knob to WARMER (red) and the indoor air will become warmer. 3800 Series only When the outdoor temperature is lower than 20°F, heat is provided by the electric heater in the air conditioner instead of by the heat pump. Mode Control HIGH COOL and LOW COOL provide cooling with different fan speeds. HIGH HEAT and LOW HEAT provide heating with different fan speeds. LOW FAN or HIGH FAN provides air circulation and filtering without cooling or heating. NOTE: If you move the switch from a cool or heat setting to STOP or to a fan setting, the unit has an automatic 3-minute delay before allowing the compressor to restart in the cool or heat mode. TEMP CONTROL MODE CONTROL About the controls on your Zoneline. ge.com About Your Heat Pump (3800 Series only) Heat pumps can save money by removing heat from the outside air—even when the outside temperature is below freezing—and releasing that heat indoors. To get the best performance from your heat pump, don’t change the room thermostat very often. Raising the heat setting 2–3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperature setting quickly. There is a three minute minimum compressor run time at any setting to prevent short cycling. The indoor fan motor starts before the compressor and stops after the compressor cycles off. The electric heating elements use much more electricity than heat pumps and cost more to operate. Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions Ventilation Control The ventilation control lever is located at the upper left side of the Zoneline unit, behind the room cabinet. When set at the closed position, only the air inside the room is circulated and filtered. When set at the open position, some outdoor air will be drawn into the room. This will reduce the heating or cooling efficiency. Energy Tip: Keep the vent control at the closed position. The room air will be filtered and circulated. NOTE: Two shipping screws must be removed from the vent door before use. See the Installation Instructions in the back of this manual. Air Direction To adjust the air direction, remove the room cabinet. Remove the 7 louver screws that hold the louver insert in place. Flip the louver insert 180°, replace the screws and the room cabinet. Remove the room cabinet and flip the louver insert to change the air direction. 4 Other features of your Zoneline. To Remove the Room Cabinet Additional controls are located behind the room cabinet. To remove: Pull out at the bottom to release it from the tabs (1). Then lift up (2). To replace: Place the tabs over the top rail (1). Push inward at the bottom until it snaps into place (2). Vent control (shown in middle position) Open position Closed position Louver screws Louver screws

Document Preview & Text Transcription

www.GEAppfiances.com © © Safety Instructions ........... 9 Operating Instructions Air Direction ................ 4 Auxilia, T Controls .......... 5-9 Controls .................... 3 To Remoxe the Room Cabinet . .4 Vent Control ................ 4 Care and Cleaning Air Fihers .................. 11 Base Pan .................. 10 Outdoor Coils .............. ] 0 Room Cabinet and Case ...... 10 Vent Filmr . ................ 10 Installation Instructions Electrical Supply ......... 14-1 7 Installing the Zoneline .... 18, 19 Optional Drain Kit .......... 20 Preparation ................ 19 Replacing an Exisung Unit? . . .13 Troubleshooting Tips .... 21,22 Normal Operating Sounds .... 23 Consumer Support Consumer Support . . .Back Cover Product Registration ...... 25, 26 _'arranty .................. 27 Write the model and serial numbers here: Model # Serial # Find these numbex_ on a label behind the room cabinet on the base pan. Heat/Cool Model 2800 Heat Pump Model 3800 Conditionneur d'air Zoneline ® La section frangaise commence a la page 29 Acondicionador de aire Zoneline ® La seccion en espa#ol empieza en la pagina 57 TINSEA381JBflZ 494484-1 05-04Jfl IMPORTANTSAFETYINFORMATION. READALLINSTRUCTIONSBEFOREUSING. WARNING! For your safe_ the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. SAFETYPRECAUTIONS This Zoneline must be properly installed in accordance with the Installation Instructions before it is used. See the Installation Instructions in the back of this manual. Replacing an existing unit? For details, see the Installation Instructions in this manual. • Immediately repair or replace all electric service cords that have become flaved or otherwise damaged. • Unplug or disconnect the Zoneline at the fllse box or circuit breaker before making any repairs. NOTE; ¼:e strongly recommend that any servicing be performed by a qualified individual. READANDFOLLOWTHISSAFETYINFORMATION CAREFULLY. SAVETHESEINSTRUCTIONS 2 Aboutthe controlsonyourZoneline. CEA..lia.cescom / TEMPCONTROL 0 MODECONTROL @ Co trols TempControl The temp control is used to maintain the I'00111 tell/pei'att/i'e. The COlll[)i'essoi" will c_cle on and off to kee I) the room at the same comtort level. _,_]_en w)u tm'n the knob to COOLER(blue), the indoor air will become cooler. Tm'n the knob to WARMER (red) and the indoor air will becollle wa illlei i 3800Series only _,_]_en the outdoor temperatm'e is lower than 20°E heat is provided b)' the electric heater in the air conditioner instead of bv the heat I)ump. Mode Control HIGH COOLand LOW COOLpr_Mde cooling with different tim speeds. HIGHHEATand tOW HEATprovide heating with different tim speeds. LOWFAN or HIGH FAN provides air circulation and filtering without cooling or heating. NOTE:If youmove the switch from a cool orheat setting to STOPorto a fan setting, the unit hasan automatic 3-minute delaybefore allowing the compressorto restart in thecool or heat mode. About Your Heat Pump (3800 Series only) Heat pmnps can save money by removing heat fl'om the outside air----even when the outside temperature is below freezing--and releasing that heat indom_. To get the best pet_kmnance flxm_ ):ore" heat l)ump, don't change the room them_ostat ve_y otten. Raising the heat setting 2-3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperatm'e setting quickly. There is a three mimlte minimum compressor run time at any setting to prevent shin* cycling. The indoor tim motor starts befl)re the COllll)I'essoI" and stops aJ[teI" the coI/ll)I'essoI" cycles off. The electric heating elements use much more electricit_ than heat pmnps and cost II/OI'e to ol)erate. 3 Otherfeaturesof yourZoneline. Ventilation Control The xentilation control lexer is located at the upper lett side of the Zoneline unit, behind the room cabinet. _4q_en set at the closed position, onE' the air inside the room is circulated and filtered. X_]_en set at the open position, some outdoor air will be drawn into the room. This will reduce the heating or cooling efficiency. Energy Tip: Kee I) the vent control at the closed position. The room air will be filtered and circulated. NOTE:Twoshippingscrewsmustberemovedfromthe ventdoorbeforeuse.Seethe/nstal/aflonInstructions in thebackof thismanual Open position Vent control Closed (shownin position middle position) ToRemovethe RoomCabinet Additional controls are located 1)ehind the I'OOIll cabinet. To remove:Pull out at the bottom to release it fl'om the tabs (l). Then lift up (2). To replace: Place the tabs oxer the top rail ( l ). Push imvard at the bottom tmtil it snaps into place (2). Air Direction To a(!just the air direction, remove the room cabinet. Remove the 7 louver screws that hold the louver insert in place. Flip the louver insert 180°, replace the screws and the room cabinet. Louverscrews Removethe room cabinet and flip the louver insert to change the air direction, Louverscrews 4

Document Preview & Text Transcription

ge.com © © Safety Instruc_tions ........... 2 Operating Instructions Air Direction ................ 4 Auxiliary Controls .......... 5-9 Controls .................... 3 To Remo_e the Room Cabinet . .4 Vent Control ................ 4 Care and Cleaning Air Filters .................. 11 Base Pan .................. 10 Outdoor Coils .............. 10 Room Cabinet and Case ...... 10 Vent Filter ................. 10 Installation Instruc_tions Electrical Supply ......... 14-17 Installing the Zoneline .... 18, 19 Optional Drain Kit .......... 20 Preparation ................ 12 Replacing an Existing Unit? . . .13 Troubleshooting Tips .... 21,22 Normal Operating Sounds .... 23 Consumer Support Consumer Support . . .Back Cover Product Registration ...... 25, 26 *¢\,_rranty .................. 27 Heat/Cool Modal 2800 Heat Pump Model 3800 Espa_ol For a Spanish version of this manual, visit our _Yebsite at Be.com. Para consultar una version en espaflol de este manual de instrucciones, visite nuestro sitio de internet w_v.GEAppliances.com. Fran_aise For a French version of this manual, visit our V¢ebsite at w_v.GEAppliances.com. Pour une version fiangaise de ce manuel d'utilisation, veuillez visiter notre site web _ l'adresse w_v.GEAppliances.com. ® Write the model and serial numbers here: Model # Serial # Find these numbers on a label behind the room cabinet on the base pan. TINSEA471JBRZ 49-7538 12-05JR IMPORTANTSAFETYINFORMATION. READALLINSTRUCTIONSBEFOREUSING. WARNING! For your safe_ the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, personal injury, or loss of life. SAFETYPRECAUTIONS • This Zoneline must be properly installed in accordance with tile Installation Instructions before it is used. See the Installation Instructions ira tile hack of this manual. Replacing an existing unit? For details, see the Installation Instructions in this manual. • Replace immediately all electric service cords that have become flaved or otherwise damaged. A damaged power supply cord must he replaced with a new power supply cord ohtained flom the mamffacturer and not repaired. Do not use a cord that shows cracks or ahrasion damage along its length or at either tile plug or connector end. • Unplug or disconnect tile Zoneline at tile fllse box or circuit hreaker before making any repairs. NOTE: ¼:e strongly recommend that any servicing be performed hv a qualified individual. READANDFOLLOWTHISSAFETYINFORMATION CAREFULLY. SAVETHESEINSTRUCTIONS 2 Aboutthe controlsonyourZoneline. ge.com [, % TEMPCONTROL @ MODECONTROL @ Co trols TempControl The temp control is used to maintain the I'00111 telllpei'attli'e. The coi/li)i'essoi" will c_cle on and off to kee I) the room at the same comfort level. _]_en you tm'n the knob to COOLER(blue), the indoor air will become coole_: Tm'n the knob to WARMER (red) and the indoor air will become war/nei: 3800Series only _]_en the outdoor temperatm'e is lower than 90°E heat is provided b)' the electric heater in the air conditioner insmad of bv the heat I)ump. Mode Control HIGH COOLand LOW COOLpr_vi(le cooling with different tim speeds. HIGHHEATand tOW HEATprovide heating with different tim speeds. LOWFAN or HIGH FAN provides air circulation and filtering without cooling or heating. NOTE:If youmove the switch from a cool orheat setting to STOPorto a fan setting, the unit hasan automatic 3-minute delaybefore a//owlbg the compressorto restart in thecool or heat mode. About Your Heat Pump (3800 Series only) Heat l)mnps can save money by removing heat fl'om the outside ai_e\'en when the outside temperature is below fl'eezing--and releasing that heat indom_, To get the best perlommnce fl'om ):our heat pmnp, don't change the room them_ostat ve_T often. Raising the heat setting 2-3 degrees will cause the Zoneline to use its electric heating elements in order to reach the new temperatm'e setting quickly. There is a three mimlte minimum compressor run time at any setting to prevent short cycling. The indoor tim motor starts beli)re the COllll)I'essoI" and stops aJ[teI" the cOI/ll)I'essoI" cycles off'. The electric heating elements use much more electricit_ than heat pmnps and cost II/OI'e to operate. 3
GE Appliances Zoneline 2800 Data manual Main Page Preview

Data manual [PDF] (60 pages)

  • Updated: 09.06.2026

Document Preview & Text Transcription

GE Zoneline ® packaged terminal air conditioners 2007 contract sales architects and engineers data manual Quick Reference 2800 Series Cooling with Electric Heat 2800 and 3800 Series Control Panel 5800 Series Control Panel Full Specs on pages 54 and 55 ALL UNITS REQUIRE POWER CONNECTION KIT Power Connection Kit determines resistance heat output 7000 Btuh units do not activate 5 KW resistance heater MODEL NUMBER COOLING (Btuh) EER AZ28E07DA* 7100/6900 12.7/12.7 AZ28E09DA* 9300/8900 12.0/12.0 AZ28E12DA* 11800/11500 11.5/11.5 AZ28E15DA* 14600/14300 10.2/10.2 AZ28E07EA* 7100 12.7 AZ28E09EA* 9000 12.0 AZ28E12EA* 11700 11.5 AZ28E15EA* 14600 10.2 Dry Air 25 2800 Series Cooling with Electric Heat MODEL NUMBER COOLING (Btuh) EER AZ28E07DAP 6800/6600 12.1/12.1 AZ28E09DAP 8600/8400 11.5/11.5 AZ28E12DAP 11200/11000 11.0/11.0 AZ28E07EAP 6800 12.1 AZ28E09EAP 8600 11.5 AZ28E12EAP 11200 11.0 3800 Series Heat Pump with Backup Electric Heat MODEL NUMBER COOLING (Btuh) EER Reverse Cycle BTUH COP AZ38H07DA* 7100/6900 12.7/12.7 6400/6200 3.6/3.6 AZ38H09DA* 9000/8800 12.0/12.0 8400/8200 3.6/3.6 AZ38H12DA* 11700/11500 11.5/11.5 10900/10700 3.4/3.4 AZ38H15DA* 14600/14300 10.0/10.0 13400/13200 3.2/3.2 AZ38H07EA* 7100 12.7 6400 3.6 AZ38H09EA* 9000 12.0 8400 3.6 AZ38H12EA* 11700 11.5 10900 3.4 AZ38H15EA* 14600 10.0 13400 3.2 5800 Series Heat Pump with Backup Electric Heat MODEL NUMBER COOLING (Btuh) EER Reverse Cycle BTUH COP AZ58H07DA* 7200/7000 13.0/13.0 6400/6200 3.7/3.7 AZ58H09DA* 9300/9050 12.0/12.0 8400/8200 3.6/3.8 AZ58H12DA* 11800/11600 11.7/11.7 10900/10700 3.4/3.4 AZ58H15DA* 14700/14400 10.3/10.3 13800/13800 3.2/3.2 AZ58H07EA* 7300 13.0 6400 3.7 AZ58H09EA* 9300 12.0 8400 3.6 AZ58H12EA* 11800 11.7 10900 3.4 AZ58H15EA* 14700 10.3 13800 3.2 *Dual rated 230/208-volt units are shown with ratings separated by “/”. Units with single rating are 265-volt units. 2 3 ge.com Electric Heat Amps include electric heater and fan motor current draw. 265-volt units are to be permanently connected in compliance with National Electrical Code and local codes and have a factory-installed junction box on the chassis. Each 265-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-base to chassis and wiring to connect sub-base to building wiring. 265-Volt Power Connection Kit must be ordered separately. Power Connection Kits Zoneline® Chassis Nomenclature The Zoneline chassis is identified by a model number defining the type of unit, cooling capacity, electrical information and optional features included on the unit. When specifying or ordering the Zoneline chassis, the use of this nomenclature will assure receiving the correct unit. 230/208-Volt Line Cord Connection Units Line Cord Kit Electric Heat BTUH Electric Heater Watts Electric Heat Amps Min. Circuit Protection (Amps) RAK3153 8600/7100 2550/2090 11.6/10.6 15 RAK3203 11700/9600 3450/2820 15.5/14.1 20 RAK3303 170100/13900 5000/4090 22.3/20.3 30 Electric Heat Amps include electric heater and fan motor current draw. Each Line Cord Kit has an integral Leakage Current Detection and Interruption (LCDI) or Arc Fault Current Interrupter (AFCI) device as required by National Electrical Code (NEC) and Underwriters Laboratories (UL) for units manufactured after August 1, 2004. 230/208-Volt Sub-Base and Direct Connected Units Sub-Base Direct Connection Kit Electric Heat BTUH Electric Heater Watts Electric Heat Amps Min. Circuit Protection (Amps) RAK204D15P RAK4157 8600/7100 2550/2090 11.6/10.6 15 RAK204D20P RAK4207 11700/9600 3450/2820 15.5/14.1 20 RAK204D30P RAK4307 170100/13900 5000/4090 22.3/20.3 30 Electric Heat Amps include electric heater and fan motor current draw. Units connected through sub-base do not require a LCDI or AFCI device since they are not considered to be line-cord connected. Each 230/208-volt sub-base kit consists of sub-base with appropriate receptacle for minimum circuit amperage, chaseway to route power connector from sub-base to chassis, wiring to connect sub-base to building wiring and a short line cord with 9-pin connector to connect to chassis and plug into receptacle in sub-base. Short sub-base line cord may not be used without sub-base. Junction box for 230/208-volt chassis must be purchased separately. RAK4002A for 2800 and 3800 series units RAK4002B for 5800 series units. 265-Volt Sub-Base and Direct Connected Units Sub-Base Power Connection Kit Direct Connection Kit Electric Heat BTUH Electric Heater Watts Electric Heat Amps Min. Circuit Protection (Amps) RAK204E15 RAK5172 RAK5157 8600 2550 9.6 15 RAK204E20 RAK5202 RAK5207 11700 3450 13.0 20 RAK204E30 RAK5302 RAK5307 17000 5000 18.9 30 Important Essential Elements Ordering Overview 230/208-volt line cord connected units — order line cord kit 230/208-volt sub-base connected units — order sub-base and junction box 265-volt units — order sub-base and power connection kit EXAMPLE A Z 5 8 H 1 2 D A D Chassis series 28=deluxe line cool/ electric heat 38=deluxe line heat pump 58=premium line heat pump Unit type E=cooling with electric resistance heat H=heat pump with electric resistance heat Zoneline packaged terminal chassis Nominal cooling capacity 07=7,000 BTUH cooling 09=9,000 BTUH cooling 12=12,000 BTUH cooling 15=15,000 BTUH cooling Special Features B=base unit C=corrosion treated D=internal condensate removal (ICR) system (heat pump models only) (not for coastal areas) P=Dry Air 25 (2800 Series only) Voltage/Phase/ Frequency D=230/208-Volt, single-phase, 60 Hz E=265-Volt, single-phase, 60 Hz Universal power connection