12-05 JR
Air Conditioners
Safety Instructions . . . . . . . . . . .2
Operating Instructions
Air Direction . . . . . . . . . . . . . . . .4
Auxiliary Controls . . . . . . . . . .5–9
Controls . . . . . . . . . . . . . . . . . . . .3
To Remove the Room Cabinet . .4
Vent Control . . . . . . . . . . . . . . . .4
Care and Cleaning
Air Filters . . . . . . . . . . . . . . . . . .11
Base Pan . . . . . . . . . . . . . . . . . .10
Outdoor Coils . . . . . . . . . . . . . .10
Room Cabinet and Case . . . . . .10
Vent Filter . . . . . . . . . . . . . . . . .10
Installation Instructions
Electrical Supply . . . . . . . . .14–17
Installing the Zoneline . . . .18, 19
Optional Drain Kit . . . . . . . . . .20
Preparation . . . . . . . . . . . . . . . .12
Replacing an Existing Unit? . . .13
Troubleshooting Tips . . . .21, 22
Normal Operating Sounds . . . .23
Consumer Support
Consumer Support . . .Back Cover
Product Registration . . . . . .25, 26
Warranty . . . . . . . . . . . . . . . . . .27
Heat/Cool Model 2800
Heat Pump Model 3800
Owner’s Manual and
Installation Instructions
ge.com
Write the model and serial
numbers here:
Model # ____________________
Serial # ____________________
Find these numbers on a label
behind the room cabinet on the
base pan.
Zoneline
®
Español
For a Spanish version of this
manual, visit our Website at
ge.com.
Para consultar una version
en español de este manual
de instrucciones, visite
nuestro sitio de internet
www.GEAppliances.com.
Française
For a French version of this
manual, visit our Website at
www.GEAppliances.com.
Pour une version française de
ce manuel d’utilisation, veuillez
visiter notre site web à l’adresse
www.GEAppliances.com.
Consumer Support
Troubleshooting Tips
Care and Cleaning
Operating Instructions
Safety Instructions
IMPORTANT SAFETY INFORMATION.
READ ALL INSTRUCTIONS BEFORE USING.
WARNING!
For your safety, the information in this manual must be followed to minimize the risk of fire or
explosion, electric shock, or to prevent property damage, personal injury, or loss of life.
I This Zoneline must be properly
installed in accordance with the
Installation Instructions before it is
used. See the Installation Instructions
in the back of this manual.
I Replace immediately all electric service
cords that have become frayed or
otherwise damaged. A damaged power
supply cord must be replaced with a
new power supply cord obtained from
the manufacturer and not repaired.
Do not use a cord that shows cracks
or abrasion damage along its length
or at either the plug or connector end.
I Unplug or disconnect the Zoneline at
the fuse box or circuit breaker before
making any repairs.
NOTE: We strongly recommend that any
servicing be performed by a qualified
individual.
Replacing an existing unit?
For details, see the Installation
Instructions in this manual.
SAFETY PRECAUTIONS
READ AND FOLLOW THIS SAFETY INFORMATION CAREFULLY.
SAVE THESE INSTRUCTIONS
2
Safety Instructions
Operating Instructions
Care and Cleaning
Troubleshooting Tips
Consumer Support
3
Controls
Temp Control
The temp control is used to maintain the
room temperature. The compressor will
cycle on and off to keep the room at the
same comfort level. When you turn the
knob to COOLER (blue), the indoor air
will become cooler. Turn the knob to
WARMER (red) and the indoor air will
become warmer.
3800 Series only
When the outdoor temperature is lower
than 20°F, heat is provided by the electric
heater in the air conditioner instead of by
the heat pump.
Mode Control
HIGH COOL and LOW COOL provide cooling
with different fan speeds.
HIGH HEAT and LOW HEAT provide heating
with different fan speeds.
LOW FAN or HIGH FAN provides air
circulation and filtering without cooling
or heating.
NOTE: If you move the switch from a cool or heat
setting to STOP or to a fan setting, the unit has an
automatic 3-minute delay before allowing the
compressor to restart in the cool or heat mode.
TEMP CONTROL
MODE CONTROL
About the controls on your Zoneline.
ge.com
About Your Heat Pump (3800 Series only)
Heat pumps can save money by removing heat
from the outside air—even when the outside
temperature is below freezing—and releasing
that heat indoors.
To get the best performance from your heat
pump, don’t change the room thermostat very
often. Raising the heat setting 2–3 degrees will
cause the Zoneline to use its electric heating
elements in order to reach the new temperature
setting quickly.
There is a three minute minimum compressor
run time at any setting to prevent short cycling.
The indoor fan motor starts before the
compressor and stops after the compressor
cycles off.
The electric heating elements use much
more electricity than heat pumps and cost
more to operate.
Consumer Support
Troubleshooting Tips
Care and Cleaning
Operating Instructions
Safety Instructions
Ventilation Control
The ventilation control lever is located at the
upper left side of the Zoneline unit, behind
the room cabinet.
When set at the closed position, only the air
inside the room is circulated and filtered.
When set at the open position, some outdoor
air will be drawn into the room. This will
reduce the heating or cooling efficiency.
Energy Tip: Keep the vent control at the closed
position. The room air will be filtered and
circulated.
NOTE: Two shipping screws must be removed from the
vent door before use. See the Installation Instructions
in the back of this manual.
Air Direction
To adjust the air direction, remove the room
cabinet. Remove the 7 louver screws that hold
the louver insert in place. Flip the louver insert
180°, replace the screws and the room cabinet.
Remove the room cabinet and flip the louver
insert to change the air direction.
4
Other features of your Zoneline.
To Remove the Room Cabinet
Additional controls are located behind the
room cabinet.
To remove: Pull out at the bottom to release it
from the tabs (1). Then lift up (2).
To replace: Place the tabs over the top rail (1).
Push inward at the bottom until it snaps into
place (2).
Vent
control
(shown in
middle
position)
Open
position
Closed
position
Louver screws
Louver screws
Pages Preview: