GE GE 15136 Manuals

1 pdf manual(s) GE GE 15136 for free download (Document Types: Quick start manual)

GE GE 15136 Quick start manual [PDF] (3 pages)

  • Identifier: id-825674
  • Brand: GE
  • Device: GE 15136 Timer
  • Type: PDF
  • Key Aspects: Control Panel and Interface Navigation, Hardware Setup Instructions, Efficiency and Calibration Tips
  • UPD Date: 13.08.2026
  • Source File: 814088.pdf
  • Pages: 3
  • Description: Stepwise user guide for the GE GE 15136.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
APPLICATION This digital GE Time Switch (15132) is a universal, electromechanical time switch which can be field configured for various power supply voltages. The voltage options include 120VAC, 208/240VAC and 277VAC – all within the same unit! Selection of the desired supply voltage is easily achieved by positioning dipswitches on the printed circuit board assembly (consult Dipswitches Configuration on back). The mechanism is mounted in a NEMA indoor or outdoor enclosure and is intended for the control of lighting, heating, air conditioning, pumps, motors, or general electrical circuits in residential, commercial, industrial and agricultural facilities. SPECIFICATIONS Input Voltage: 120 VAC, 208/240 VAC, or 277 VAC in all units based upon dipswitch configuration. 15087 NEMA 3R Indoor & Outdoor BM-A301US5-O2 15207 NEMA 1 Indoor BM-A301US5-I2 56922 NEMA 1 Indoor BM-A301US5-I2 15132 NEMA 3R Indoor & Outdoor EM-A301US9-O2 Switch Rating: DPDT Models Normally Open Contacts 40A Resistive, 120-277Vac. 30A General Purpose, 120-277Vac. 20A Resistive, 30Vdc 1 HP, 120Vac ; 2HP, 240Vac ; 20A Ballast, 120-277Vac. 15A Tungsten, 120Vac 5.4A Tungsten, 208-277Vac. 800VA, Pilot Duty, 120Vac. 720VA, Pilot Duty, 240-277Vac. TV-5, 120Vac Normally Closed Contacts 30A Resistive, 120-277Vac 15A General Purpose, 120-277Vac 15A Resistive, 30Vdc 20A Ballast, 120-277Vac 1/4HP, 120Vac; 1/2HP, 208-240Vac. 290VA, Pilot, 120Vac. 360VA, Pilot, 208-240Vac. NOTE: If loads are connected to both NC and NO contacts, both contacts are decorated to 67% of the above values. ENVIRONMENTAL RATINGS Ambient Temperature: –40F to 130F Humidity: 0-95% RH, Non-condensing WIRING CONNECTIONS Screw clamp terminals for up to 2 AWG #8 wires per position. For supply connections, use 8AWG or larger wires suitable for at least 105° C. Use copper conductors only. Lights Power LED (Orange) – Light illuminates when power is applied to the timer Status LED (Green) – Light illuminates when power is applied to load. Included Hardware INSTALLATION CAUTION: Before wiring or servicing, power to this time switch and the equipment it controls must be turned off. Turning off the time switch only will not prevent a shock hazard. Replace cover plate within housing before supplying power to time switch. If you are not comfortable installing this device please contact a licensed electrician. Before installing this product read all instructions carefully. Removing Knockout 1. Select knockouts to be used. Remove the inner 1/2” knockout by inserting a flathead screwdriver on the inner most ring and carefully punching the knockout loose. Remove slug. If the 3/4” knockout is required, remove the outer ring with pliers after removing the 1/2” knockout. Smooth edges with a knife if necessary. Please refer to Quick Start Guide for Examples and More Details. Mounting of the Time Switch Box NOTE - Before mounting be sure to remove knockouts for the wires, (see Quick Start Guide) 1. In order to mount the box you will need the 3 supplied anchors and 3 supplied screws from the hardware list above. (Anchors included are designed for mounting on sheetrock.) 2. Using the box as a template, mark with a pencil where the three pilot holes will be drilled. 3. Using the appropriate drill bit size, drill the pilot holes (Note that if drilling into wood or metal a specialized drill bit may be needed.) See Drill Diagram. 4. For sheetrock; use a hammer to gently tap the anchors into the pilot holes. 5. Place the box up to the pilot holes or anchors and insert the screws accordingly. Wiring the Device to the Timer NOTE - For outdoor installation use rain tight or wet location conduit hubs that comply with requirements of UL 514B (standard for fittings for conduit and outlet boxes). 1. Remove 2 screws retaining the interior cover panel and remove the panel. 2. Refer to Figure 1 and wiring diagrams to determine appropriate placement of wires. It is the responsibility of the installer to ensure that all applicable National and Local code requirements are met. If you are unsure of these requirements, contact a licensed electrician immediately. 3. GROUNDING: This enclosure is of plastic construction and does not require a ground connection. This enclosure does not provide grounding between Digital Time Switch Soft Wood 5/64” Material Drill Bit Size Drill Diagram Hard Wood 3/32” Metal 5/64” Sheetrock 3/16” No Anchors Needed? No No Yes QTY Hardware 3 M4 Anchors 1” Long 3 M4 Screws 1” Long 2 8 AWG Jumpers for 240V AC 2 10 AWG Jumpers for 120V AC 1 Wire Nut (For Ground Wires) 15136 NEMA 3R Indoor & Outdoor GE 15136 Timer http://waterheatertimer.org/How-to-wire-GE-15136-timer.html

GE GE 15136: Timer Category Related Instructions

DTR-20
Entes DTR-20
22.07.2026 17 pages

������������� ���������������������� �������� ����������������������������������� Product reference manual for the Entes DTR-20 Timer. This reference includes adjustment procedures, replacement parts, specifications.

SP2
Protectrix SP2
07.08.2026 2 pages

2013-11-10 ProtectrixDP2 and SP2 - Automatic Garage Door Closer Manual Start – Setup SP2 & DP2 Thank you for your purchase of the Protectrix™ Automatic Garage Door Closing Timer. This manual supports SP2, S+, DP2 and (( )) models. Video - of how to install User support guide for the Protectrix SP2 Timer. This manual elaborates on network configuration, device instructions, regulatory notices, performance guidelines.

Apollo 12
Titan Controls Apollo 12
23.06.2026 2 pages

Note : This unit has been set to perform 24-hour control. For night or day only control, refer to Optional settings. Note : Ce contrôle est configuré pour opérer jour et nuit. Pour opérer de nuit ou de jour seulement, voir Réglages optionnels. Nota : Est Usage and setup manual for the Titan Controls Apollo 12 Timer. The guide explains operation and operational guidelines, usage examples, software updates, application scenarios.

DTM-9
EMX Industries, Inc. DTM-9
23.06.2026 2 pages

DTM-9 SEVEN DAY PROGRAMMABLE ELECTRONIC TIMER DTM-9 • Has a large display and control push-buttons for easy operation • Has a back-up rechargeable battery for power outages or brown out. The power input is protected by MOV and a fuse. • Has the flexibili Quick reference guide for the EMX Industries, Inc. DTM-9 Timer. It contains information on testing procedures, firmware updates, performance guidelines.