GE PROFILE JS998SK Manuals

1 pdf manual(s) GE PROFILE JS998SK for free download (Document Types: Dimensions and installation information)

GE PROFILE JS998SK Dimensions and installation information Thumbnail

GE PROFILE JS998SK Dimensions and installation information [PDF] (2 pages)

  • Identifier: id-643568
  • Brand: GE
  • Device: GE PROFILE JS998SK Cooktop
  • Type: Dimensions and installation information, PDF
  • Key Aspects: Unpacking and Inspection Guidelines, Periodic Inspection Checklists, Performance Optimization Tips
  • UPD Date: 17.07.2026
  • Source File: 639363.pdf
  • Pages: 2
  • Description: User support manual for the GE PROFILE JS998SK.
Pages Preview:
  • GE PROFILE JS998SK Dimensions and installation information preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
For answers to your Monogram,® GE Profile™ or GE® appliance questions, visit our website at ge.com or call GE Answer Center® service, 800.626.2000. JS998SK GE Profile™ 30" Slide-In Electric Range with Trivection™ Technology Specification Revised 7/09 220454 All GE ranges are equipped with an Anti-Tip device. The installation of this device is an important, required step in the installation of the range. Listed by Underwriters Laboratories Dimensions and Installation Information (in inches) Note: Cabinets installed adjacent to slide-in ranges must have an adhesion spec of at least 194° temperature rating. Note: To reduce the possibility of scorching the side walls above the countertop when no load is present on burners, it is recommended that a minimum 6” spacing from adjacent side wall be allowed for possible extended high-heat element operation. Receptacle Locations: For all 30" Slide-In Ranges locally approved flexible service cord or conduit must be used because terminals are not accessible after range installation. See shaded area in drawing for location of electrical outlet box. Recommended outlet locations allow range to be installed directly against rear wall. KW Rating 240V 12.8 208V 8.7 Breaker Size 240V 40 Amps 208V 40 Amps Installation information: Before installing, consult installation instructions packed with product for current dimensional data. Optional Kits For Slide-In Electric Ranges (Available At Additional Cost) Accessory Backguards (Attaches to the back of range as a backguard when unit is installed in 30" free-standing cutout) JXS32SS (Stainless) - 4" High JXS32WW (White) - 4" High JXS32BB (Black) - 4" High JXS37WW (White) - 5-1/4" High JXS37CC (Bisque) - 5-1/4" High JXS37BB (Black) - 5-1/4" High Body Sides (Slide-in ranges are sold without sides installed. Can be installed on either left or right when unit has one exposed side [no cabinet adjacent]. Kit contains 1 body side) JXS77WW (White) JXS77BB (Black) Rear Filler Strip WB07T10680 - Black Filler Strip Assembly Optional Lower Trim Kits (If counter height is greater than 36.5", a lower trim kit is recommended to extend the useful height to 38" maximum) JXS56WW – White JXS56BB – Black 28-1/4* 36 Maintain at least 6" from nearest combustible surface. Acceptable Electrical Outlet Area 30" Slide-In Range Dimensions (in inches) 45-1/8 2-1/4 5 6 4-1/2 30 30" Min. 15" Min. 6 30" Slide-in Elec. Range Aug. 8, 2003 -km 23-3/16 30 30 If you are NOT using the Filler strip or Backguard: If you are using the Filler strip or Backguard: 25 *Wall to front of closed door handle on model JSP34. 28" on models JSP26/JSS26/16. Note: Range may be placed with 0" clearance (flush) at the back wall and side walls below countertop if the range side trims above the countertop extend beyond the cabinet fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest combustible surface. 30 31-1/2 28-1/4* 36 Maintain at least 6" from nearest combustible surface. Acceptable Electrical Outlet Area 30" Slide-In Range Dimensions (in inches) 45-1/8 2-1/4 5 6 4-1/2 30 30" Min. 15" Min. 6 30" Slide-in Elec. Range Aug. 8, 2003 -km 23-3/16 30 30 If you are NOT using the Filler strip or Backguard: If you are using the Filler strip or Backguard: 25 *Wall to front of closed door handle on model JSP34. 28" on models JSP26/JSS26/16. Note: Range may be placed with 0" clearance (flush) at the back wall and side walls below countertop if the range side trims above the countertop extend beyond the cabinet fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest combustible surface. 30 31-1/2 Acceptable Electrical Outlet Area 30" Min. 30" Min. Shave Raised Edge To Clear 31-1/8" Wide Control Panel Excluding Models JSS28 and JSP39 2-7/8" To Front Surface Of Countertop 20-5/8" Door Clearance From Front Surface of Countertop 31-1/4 30 25-3/4** Recommended 6" Min. From Walls 23-3/16 15" Min. A/B* 13" Max. 2-1/2 30 25 9/16 7-1/2 2-1/2 Accessory Backguard 24 36-1/4 *JXS37 is 5 (excluding handle) **Total depth front of clo including h 35-7/8"–38" from floor to countertop If the countertop area is not flat, excess tension may be applied to the glass cooktop causin and voiding the warranty. Make sure the wall covering, countertop, flooring and cabinets aro can withstand the heat (up to 200˚F) generated by the range. A. Allow 30" minimum clearance between surface units and bottom of unprotected wood or or allow a 24" minimum when bottom of wood or metal cabinet is protected by no less the flame retardant millboard covered with no less than No. 28 MSG sheet metal (.015" thick Acceptable Electrical Outlet Area 30" Min. 30" Min. Shave Raised Edge To Clear 31-1/8" Wide Control Panel Excluding Models JSS28 and JSP39 2-7/8" To Front Surface Of Countertop 20-5/8" Door Clearance From Front Surface of Countertop 31-1/4 30 25-3/4** Recommended 6" Min. From Walls 23-3/16 15" Min. A/B* 13" Max. 2-1/2 30 25 9/16 7-1/2 2-1/2 Accessory Backguard 24 36-1/4 *JXS37 is 5-1/4" and (excluding handle) **Total depth from wal front of closed oven including handle is 2 35-7/8"–38" from floor to countertop If the countertop area is not flat, excess tension may be applied to the glass cooktop causing breakage and voiding the warranty. Make sure the wall covering, countertop, flooring and cabinets around the rang can withstand the heat (up to 200˚F) generated by the range. A. Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabine or allow a 24" minimum when bottom of wood or metal cabinet is protected by no less then 1/4" thick flame retardant millboard covered with no less than No. 28 MSG sheet metal (.015" thick), .015" thick stainless steel, .025" aluminum or .020" copper. B. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, a minimum 6" spacing to surfaces less than 15" above the cooktop and adjacent cabinetry is recommended to reduce exposure to steam, grease splatter and heat. Allow 1/4" minimum clearanc at the back wall. To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space abov the cooktop should be avoided. If cabinet storage space is to be provided above the cooktop, the risk ca be reduced by installing a range hood that projects at least 5" beyond the front of the cabinets. Cabinets installed above the cooktop must be no deeper than 13".

Similar Manuals in the Cooktop Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Whirlpool RF310PXY

PDF Manual (@774T18), Whirlpool RF310PXY Cooktop (16-04-2026)

28 790 174 16-04-2026 view all manuals
GE 164D3333P027

GE Cooktop Use and care manual (File: PDF, 13-03-2026)

24 0.53 Mb 670 128 13-03-2026 view all manuals
Frigidaire FPIC3695MSA

FPIC3695MSA (Cooktop ePDF User Guide, #81F8JM)

18 1208 290 30-06-2026 view all manuals
Miele KM391

Miele Cooktop Operating instructions manual (File: PDF, 17-06-2026)

36 121 25 17-06-2026 view all manuals
Amana AKR2000 series

#X727TZ: AKR2000 series Cooktop Owner's manual

8 163 38 23-05-2026 view all manuals
Bosch NGM5056UC

PDF User Manual (@6X4UT7), Bosch NGM5056UC Cooktops (03-09-2026)

36 148 30 03-09-2026 view all manuals