6150-ID SHARPSHOOTER™ PIR
installation instructions
Sunlight or
reflected sunlight
Description
The 6150-ID (Figure 1) is an addressable PIR device that
interfaces with the PinPoint system. This system provides
flexible and reliable two-way communication between the
device and the controller.
Mounting location
Avoid false alarm sources (Figure 2)
The unit should not “see” sources of heat or cold. For
false alarm free operation, no part of an unwanted hot
spot should enter any part of a zone.
Locate for cross traffic (Figure 3)
Place the unit where intruders move across the beams,
not toward the unit. For best detection, an intruder
should cross the entire zone.
Do not block the coverage pattern (Figure 4)
The unit requires a clear line of sight. Inform end-users
not to block the coverage pattern with inventory or
furniture.
Figure 1. Exploded view
g
Figure 2.
False alarm sources
Sliding LED cover
Standard lens
(Masking kit included)
Swivel mounting bracket
#8 x 3/4"(2cm) screw
for ball joint shoe
Front cover
Two #6 x 3/4"(2cm) screws for
mounting the bracket or case
(Two #6 wall anchors are
included for sheet rock mounting)
Mounting knockouts
Lens shield/circuit
board assembly
Base
LED
2
6150-ID Sharpshooter PIR
Installation Instructions
7.
Strip 1/4 inch (6.4 mm) of insulation from each
PinPoint wire. Connect the wiring to the appropriate
screw terminals (Figure 8) and tighten the screws.
Make sure the cable is slack in the wall to avoid
stressing the wires at their connections.
8.
Snap the cover back on the base and seal all
openings.
9.
Walk test the unit to confirm correct operation (see
Walk test).
10. Slide the LED cover up to hide the LED (Figure 1), if
desired.
Installation
1.
Run the PinPoint system wiring to the unit location.
2.
Open the unit by snapping the front cover down and
off the base (Figure 1).
CAUTION
You must be free of all static electricity
before handling sensor circuit boards.
Touch a grounded, bare metal surface
before touching ciruit boards or wear a
grounding strap.
3.
Use the masking kit (Figure 5) if you need to adjust
zone coverage for your application. See Masking.
4.
Set the pulse and sensitivity DIP switches (Figure
6). See DIP switches.
5.
Set the PinPoint address DIP switches (Figure 6).
Devices are shipped with DIP switches set to 255.
This is an invalid address. The device will not
communicate with the controller and the walk test
LED will not light until a valid address has been set.
Refer to the controller's manual to determine the
correct address setting for each unit.
6.
Pull the PinPoint wiring through the base and attach
the base to the wall using the corner or flat wall
knockouts (Figure 7). For optimal coverage using
the standard lens, mount 6 feet 10 inches (2.1 m)
above the floor.
See Swivel bracket mounting for instructions on
mounting with the swivel bracket (Figures 9 and 10).
Figure 7.
Mounting without the swivel bracket
Figure 8.
PinPoint wiring
- + - +
Corner
Flat wall
15
10
5
0
5
10
10 5
0
5 10
Wiring
knockout
Corner
mounting
knockout
Flat wall mounting
knockouts
Corner
mounting
knockout
Figure 5.
Masking
W
V
U
T
S
R
Q
P
O
N
M
A
B
C
D
E
F
G
H
J
K
L
C
STANDARD LENS
PEEL AND STICK TO GROVE SIDE OF LENS
Figure 6.
DIP switches
Pulse (1) and
sensitivity (2)
DIP switches
PinPoint address
DIP switches
on1 2
on1 2
3 4 5 6 7 8
3
Swivel bracket mounting
The swivel bracket allows aiming and adjusting the unit
for maximum detection and avoidance of false alarms
(Figure 9).
The swivel bracket’s snap-off tabs allow angle mounting,
for applications such as hallway protection. Break the
tabs off by bending them back and forth.
Use these screws for mounting:
• Two #6 x 3/4" (19 mm) screws for mounting the
bracket or the base to the wall
• One #8 x 3/4" (19 mm) screw for mounting the base
onto the bracket (insert into ball joint shoe)
Align the arrows on the ball joint shoe with the zeroes on
the base for 6 foot 10 inch (2.1 m) mounting for typical
coverage. This is the 0 degree setting. For every 1 foot
(0.3 m) above the typical mounting height, tilt the shoe
down 1 degree. For example, for 7 feet 10 inches (2.4 m),
tilt the shoe down 1 degree, or for 8 feet 10 inches (2.7 m),
tilt the shoe down 2 degrees.
Turn the swivel bracket screw (Figure 10) until snug.
DIP switches
DIP switches on the back of the circuit board (Figure 6)
set pulse, sensitivity, and PinPoint address.
Pulse (DIP switch 1)
ON
Bi-curtain mode (3 pulse), the factory default,
increases false alarm immunity in smaller areas
and requires the intruder to pass through two
curtains to trigger an alarm. Do not use for single
curtain applications or ranges under 5 feet (1.5
m).
OFF
Standard curtain mode (2 pulse) is used for wide-
angle or single-curtain applications. It requires
the intruder to only pass through one curtain to
trigger an alarm.
Notes
Operation in the standard curtain mode is for
the specified ranges of 33 feet (10.1m) and
45 feet (13.7 m).
For operation in bi-curtain mode, the unit
has 30 feet (9.1m) of range only.
For ranges from 30 to 45 feet (9.1 to 13.7
m), the unit will provide detection within 6
steps or 14 feet (4.3 m) across the plane of
coverage.
Masking
To avoid smudging the masking strips, make sure your
hands are clean before using the masking kit.
1.
To unsnap the shield from the front cover, grasp the
edge of the circuit board and gently rotate the lens
shield/circuit board assembly up from the bottom
(see figure 1). Remove the lens from the shield.
2.
Locate the lettered masking strip on the masking kit,
peel off the masking strip, and press onto the
corresponding grooved segment on the lens. The
notch of the lens must be up.
3.
Reinstall the lens in the shield. The notch on the lens
should match the notch on the shield.
4.
Snap the shield/circuit board assembly into the front
cover.
Sensitivity (DIP switch 2)
ON
High sensitivity range up to 45 feet (13.7 m)
OFF
Low sensitivity range under 33 feet (10.1 m)
(factory default)
It's important to program the unit correctly for optimum
sensitivity and walk test the unit regularly (see Walk test).
Figure 9. Swivel bracket mounting
Figure 10. Swivel bracket screw
Flat wall
one tab
Corner
two tabs
Flat wall
no tabs
Corner mounting
holes
Wiring hole
Flat wall mounting
holes
Ceiling
Corner mounting
holes
Allow 1.6 in. (40 mm)
minimum