Graco 310584D Manuals

1 pdf manual(s) Graco 310584D for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

SHARPE MANUFACTURING COMPANY • P.O. BOX 1441, MINNEAPOLIS, MN 55440-1441 1-800-742-7731, www.sharpe1.com 310584D, 4/2006 THE SPRAY GUN PEOPLE FOR PRODUCT INFORMATION CALL: 1-800-742-7731 T1-Titanium Non-HVLP Spray Gun Maximum Fluid and Air Inlet Pressure:100 psi (0.7 MPa, 7 bar) Important Safety Instructions Read all warnings and instructions in this manual. Save these instructions. Gun Part No. Needle/Nozzle Size Air Consumption (CFM) Recommended Usage 5430 1.2 mm 11* Pressure feed production 5435 1.8 mm 13.8* Medium solids, colors and clears * At 50 psi (345 kPa, 3.4 bar) II 2 G 2 310584D 3 Year Limited Warranty Sharpe warrants this product to the original user against defective material or workmanship for a period of 1 year from the date of purchase. Sharpe reserves the right to determine whether the part or parts failed because of defective material, workmanship, or other causes. Failures caused by accident, alteration, or misuse are not covered by this warranty. Sharpe, at its discretion, will repair or replace products covered under this warranty free of charge. Repairs or replacements of products covered under this warranty are warranted for the remainder of the original warranty period. Sharpe or its authorized service representatives must perform all warranty repairs. Any repair to the product by unauthorized service representatives voids this warranty. The rights under this warranty are limited to the original user and may not be transferred to subsequent owners. This warranty is in lieu of all other warranties, expressed or implied, including warranties of merchantability and fitness for a particular purpose. Some states do not allow the exclusion or limitations of incidental or consequential damages, so the above limitations may not apply to you. WARNING FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present. • Ground equipment and conductive objects in work area. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Tech- nical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. • Check equipment daily. Repair or replace worn or damaged parts immediately. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your Graco distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equip- ment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. • Tighten all fluid connections before operating the equipment. • Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. 3 310584D T1-TITANIUM NON-HVLP SPRAY GUN Setup • Check that your shop air provides adequate air flow. • Use a minimum 5/16 in. ID air supply hose. • Set air and fluid pressure regulator according to paint man- ufacturer’s recommendation for conventional equipment. Do not exceed 100 psi (0.7 MPa, 7 bar). • Make sure no air restrictions, such as low-volume cheater- valves, obstruct the air flow. If an air adjusting valve is desired, use a SHARPE Air Adjusting Valve 24AAV (part no. 2210), 36AAV-HOV (part no. 3310) or HOV (part no. U04410). • Install a shutoff valve (not supplied) downstream of the air regulator to shut off gun air. • Install a shutoff valve (not supplied) on the fluid supply line to shut off fluid to the gun. • Install an inline air filter (not supplied) to clean and dry the air supply to the gun. 1. Connect a clean, dry, filtered air supply to gun air inlet (9). 2. Connect fluid supply line to the gun fluid inlet (38). If this is first time using the equipment, flush the spray gun. 3. Operation Pressure Relief Procedure 1. Turn off gun air and fluid supply. 2. Trigger the gun to relieve pressure. Flushing Flush before using the equipment, before changing colors, and when you are done spraying. Use solvent that is compatible with gun wetted parts and fluid that will be sprayed. Flush at lowest possible pressure. 1. Follow Pressure Relief Procedure. 2. Connect a solvent supply line to the gun fluid inlet (38). 3. Spray into grounded metal waste container until equipment is clean. 4. Follow Pressure Relief Procedure. Spraying 1. Connect the fluid supply line to the gun fluid inlet (38). 2. Turn on shop air to gun and set atomizing pressure with the gun fully triggered. 3. Adjust the pattern size and shape with the spray width adjustment knob (17d). Turn knob clockwise to reduce pat- tern size and counterclockwise to increase it. 4. Fluid control knob (16) is factory set for maximum needle trigger travel and material flow. To decrease needle/trigger travel and decrease fluid flow, turn the knob clockwise. 5. Adjust fluid pressure regulator until desired fluid flow rate is reached. FIG. 1 WARNING Follow Pressure Relief Procedure when you stop spraying and before cleaning, checking, or servicing equipment. Read warnings, page 2. 17d 38 6 16 9 WARNING Read warnings, page 2. Refer to Compliant Cleaning Methods, page 4, to com- ply with air quality laws if applicable. CAUTION Excessive atomizing air pressure can increase over-spray, reduce transfer efficiency, result in a poor quality finish from dry spray. See Troubleshooting guide if you experience an irregular pattern.