Greenheck CFSD-211 Manuals
3 pdf manual(s) Greenheck CFSD-211 for free download (Document Types: Installation, operation and maintenance manual, Installation instruction booklet, Installation, operation and maintenance instructions)
Greenheck CFSD-211 Installation, operation and maintenance manual [PDF] (8 pages)
- Identifier: id-1246568
- Brand: Greenheck
- Device: Greenheck CFSD-211 Fan
- Type: Installation, operation and maintenance manual, PDF
- Key Aspects: Emergency Shutdown Procedures, Warranty and Service Information, Routine Functionality Testing
- UPD Date: 03.09.2026
- Source File: 911701.pdf
- Pages: 8
- Description: User reference manual for the Greenheck CFSD-211.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
FSD-XXX, DFD-XXX, DFDTF-XXX CFSD-XXX, SEDFD-XXX, SEFSD-XXX, IMO-XXX, anD SSFSD-XXX SErIES 1 1⁄2 and 3 Hour Fire & Combination Fire Smoke Dampers (with factory installed sleeve and actuator) Vertical and Horizontal Mount Part number 461336 Safety Warning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. This manual is the property of the owner, and is required for future maintenance. Please leave it with the owner when the job is complete. Typical Actuator RRL Control Device Standard Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove to be defective during the warranty period will be repaired or replaced at our option. Greenheck shall not be liable for damages resulting from misapplication or misuse of its products. Greenheck will not be responsible for any installation or removal costs. Greenheck will not be responsible for any service work or backcharges without prior written authorization. Due to continuing research, Greenheck reserves the right to change specifications without notice. “UL CLaSSIFIED (see complete marking on prod- uct)” “UL CLaSSIFIED to Canadian safety standards (see complete marking on product)” UL Standard 555 & 555S (Classification #R13317) FSD-XXX, SEFSD-XXX, SSFSD-XXX, DFD-XXX, SEDFD- XXX, and CFSD-XXX Series Dampers are intended for installation in accordance with combination fire smoke damper requirements established by: national Fire Protection association NFPA Standards 80, 90A, 92A, 92B, 101, & 105 IBC International Building Codes new York City (MEA listing #260-91-M) California State Fire Marshal (Listing #3225-0981:103) & (Listing #3230-0981:104) - FSD models; (Listing #3225-0981:103) - DFD models; (Listing #3230-0981:105) & (Listing 3225-0981:106) - CFSD models; (Listing #3225-0981:109) & (Listing 3230-0981:110 ) - SSFSD models receiving and Handling Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Dampers must be kept dry and clean. Indoor storage and protection from dirt, dust and the weather is highly recommended. Do not store at temperatures in excess of 100°F (38°C). Installation, Operation and Maintenance Instructions Installation Supplements Refer to the appropriate Greenheck installation supplements for special requirements: � •�Concrete�Floor�with�Steel�Deck � •�Drive�Slip�Breakaway�Connection � •�Field�Installed�Sleeve � •�Fire�Resistant�Ventilated�Duct�Assembly � •�Greenheck�Test�Switch � •�Grille�Installation � •�Metal�Stud�in�Shaftwall � •�No�Flow�Smoke�Detector � •�Open�or�Close�Indicator � •�Quick�Connect�Breakaway�Connections � •�Resettable�Link � •�Sealant�Supplement � •�Single�Side�Retaining�Angle � •�Single�3-Sided�Retaining�Angle � •�Sleeve�Extension � •�Smoke�Detector � •�Tunnel�Corridor
Greenheck CFSD-211 Installation instruction booklet [PDF] (52 pages)
- Identifier: id-2172729
- Brand: Greenheck
- Device: Greenheck CFSD-211 Fire and Smoke Dampers
- Type: Installation instruction booklet, PDF
- Key Aspects: Error Code Explanations, Glossary of Technical Terms, End-of-Life Handling and Disposal
- UPD Date: 14.07.2026
- Source File: 2114905.pdf
- Pages: 52
- Description: Professional manual for the Greenheck CFSD-211.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Instructions included in this booklet: IOM # Description Page(s) 461335 CFSD-XXX Series 2–6 461336 FSD-XXX, DFD-XXX & CFSD-XXX Series 7–15 461337 OFSD-XXX, ODFD-XXX, OFD-XXX and OSSFD-XXX Series 16–27 461666 FSD-3XXV Series 28–35 461868 FSDR-XXX, SEFSDR-XXX, & SSFSDR-XXX Models 36–42 472477 GFSD Models 43-48 474015 Single Side Retaining Angle 49-51 KIT # 826249 MULTI-BLADE FIRE DAMPERS DFD / FSD / CFSD / OFSD INSTALLATION INSTRUCTION BOOKLET FOR MULTI-BLADE FIRE & COMBINATION FIRE SMOKE DAMPERS 1
Greenheck CFSD-211 Installation, operation and maintenance instructions [PDF] (8 pages)
- Identifier: id-1490688
- Brand: Greenheck
- Device: Greenheck CFSD-211 Fire and Smoke Dampers
- Type: Installation, operation and maintenance instructions, PDF
- Key Aspects: Unpacking and Inspection Guidelines, Operational Mode Explanations, Best Practices for Everyday Use
- UPD Date: 20.08.2026
- Source File: 1507741.pdf
- Pages: 8
- Description: Instructions for safe usage of the Greenheck CFSD-211.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
InstallatIon supplements Refer to the appropriate Greenheck installation supplements for special requirements: • Shaftwall Supplement • Drywall Supplement • Wood Supplement • Smoke Detector Supplement • Tunnel Corridor Supplement • Single Side Retaining Angle Supplement • Grille Installation Supplement • Field Installed Sleeve Supplement Installation,Operation and Maintenance Instructions for FsD-xxx, DFD-xxx,DFDtF-xxx CFsD-xxx,seDFD-xxx, seFsD-xxx, Imo-xxx, anD ssFsD-xxx serIes 1 1⁄2 and 3 Hour Fire & Combination Fire smoke Dampers (with factory installed sleeve and actuator) Vertical and Horizontal mount part #461336 saFety WarnInG: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. This manual is the property of the owner, and is required for future maintenance. Please leave it with the owner when the job is complete. Typical Actuator RRL Control Device Standard Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove to be defective during the warranty period will be repaired or replaced at our option. Greenheck shall not be liable for damages resulting from misapplication or misuse of its products. Greenheck will not be responsible for any installation or removal costs. Greenheck will not be responsible for any service work or backcharges without prior written authorization. Due to continuing research, Greenheck reserves the right to change specifications without notice. “ul ClassIFIeD (see complete marking on product)” “ul ClassIFIeD to Canadian safety standards (see complete marking on product)” UL Standard 555 & 555S (Classification #R13317) FSD-XXX, SEFSD-XXX, SSFSD-XXX, DFD-XXX, SEDFD-XXX, and CFSD-XXX Series Dampers are intended for installation in accordance with combination fire smoke damper requirements established by: national Fire protection association NFPA Standards 90A, 92A, 92B & 101 BoCa national Building Codes ICBo uniform Building Codes IBC International Building Codes sBCCI standard Building Codes new york City (MEA listing #260-91-M) California state Fire marshal (Listing #3225-0981:103) and (Listing #3230-0981:104) - FSD models; (Listing #3225- 0981:103) - DFD models; (Listing #3230-0981:105) and (Listing 3225-0981:106) - CFSD models; (Listing #3225-0981:109) and (Listing 3230-0981:110 ) - SSFSD models reCeIVInG anD HanDlInG Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Dampers must be kept dry and clean. Indoor storage and protection from dirt, dust and the weather is highly recommended. Do not store at temperatures in excess of 100°F.
Similar Manuals in the Fan, Fire and Smoke Dampers Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
SystemAir SAVE VSR 300 |
SAVE VSR 300 Installation and service - 1CJ116 |
48 | 898 | 189 | 03-05-2026 | view all manuals | |
Helios BAK Series |
User Guide: Helios BAK Series (5E9JG9, Upd.12-06-2026) |
10 | 424 | 106 | 12-06-2026 | view all manuals | |
RFT CU2 |
Fire and Smoke Dampers #8G2Q4W |
60 | 146 | 24 | 13-08-2026 | view all manuals | |
actionair A60 |
#Q37NJQ: A60 Fire and Smoke Dampers General information |