Document Preview & Text Transcription (Main Page)
Click to expand and read text
FSD-XXX, DFD-XXX, DFDTF-XXX CFSD-XXX, SEDFD-XXX, SEFSD-XXX, IMO-XXX, anD SSFSD-XXX SErIES 1 1⁄2 and 3 Hour Fire & Combination Fire Smoke Dampers (with factory installed sleeve and actuator) Vertical and Horizontal Mount Part number 461336 Safety Warning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. This manual is the property of the owner, and is required for future maintenance. Please leave it with the owner when the job is complete. Typical Actuator RRL Control Device Standard Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove to be defective during the warranty period will be repaired or replaced at our option. Greenheck shall not be liable for damages resulting from misapplication or misuse of its products. Greenheck will not be responsible for any installation or removal costs. Greenheck will not be responsible for any service work or backcharges without prior written authorization. Due to continuing research, Greenheck reserves the right to change specifications without notice. “UL CLaSSIFIED (see complete marking on prod- uct)” “UL CLaSSIFIED to Canadian safety standards (see complete marking on product)” UL Standard 555 & 555S (Classification #R13317) FSD-XXX, SEFSD-XXX, SSFSD-XXX, DFD-XXX, SEDFD- XXX, and CFSD-XXX Series Dampers are intended for installation in accordance with combination fire smoke damper requirements established by: national Fire Protection association NFPA Standards 80, 90A, 92A, 92B, 101, & 105 IBC International Building Codes new York City (MEA listing #260-91-M) California State Fire Marshal (Listing #3225-0981:103) & (Listing #3230-0981:104) - FSD models; (Listing #3225-0981:103) - DFD models; (Listing #3230-0981:105) & (Listing 3225-0981:106) - CFSD models; (Listing #3225-0981:109) & (Listing 3230-0981:110 ) - SSFSD models receiving and Handling Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Dampers must be kept dry and clean. Indoor storage and protection from dirt, dust and the weather is highly recommended. Do not store at temperatures in excess of 100°F (38°C). Installation, Operation and Maintenance Instructions Installation Supplements Refer to the appropriate Greenheck installation supplements for special requirements: � •�Concrete�Floor�with�Steel�Deck � •�Drive�Slip�Breakaway�Connection � •�Field�Installed�Sleeve � •�Fire�Resistant�Ventilated�Duct�Assembly � •�Greenheck�Test�Switch � •�Grille�Installation � •�Metal�Stud�in�Shaftwall � •�No�Flow�Smoke�Detector � •�Open�or�Close�Indicator � •�Quick�Connect�Breakaway�Connections � •�Resettable�Link � •�Sealant�Supplement � •�Single�Side�Retaining�Angle � •�Single�3-Sided�Retaining�Angle � •�Sleeve�Extension � •�Smoke�Detector � •�Tunnel�Corridor
Greenheck FSD-212 Installation instruction booklet [PDF] (52 pages)
- Identifier: id-2172729
- Brand: Greenheck
- Device: Greenheck FSD-212 Fire and Smoke Dampers
- Type: Installation instruction booklet, PDF
- Key Aspects: Error Code Explanations, Glossary of Technical Terms, End-of-Life Handling and Disposal
- UPD Date: 15.04.2026
- Source File: 2114905.pdf
- Pages: 52
- Description: Installation reference manual for the Greenheck FSD-212.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Instructions included in this booklet: IOM # Description Page(s) 461335 CFSD-XXX Series 2–6 461336 FSD-XXX, DFD-XXX & CFSD-XXX Series 7–15 461337 OFSD-XXX, ODFD-XXX, OFD-XXX and OSSFD-XXX Series 16–27 461666 FSD-3XXV Series 28–35 461868 FSDR-XXX, SEFSDR-XXX, & SSFSDR-XXX Models 36–42 472477 GFSD Models 43-48 474015 Single Side Retaining Angle 49-51 KIT # 826249 MULTI-BLADE FIRE DAMPERS DFD / FSD / CFSD / OFSD INSTALLATION INSTRUCTION BOOKLET FOR MULTI-BLADE FIRE & COMBINATION FIRE SMOKE DAMPERS 1
Greenheck FSD-212 Operation & user’s manual [PDF] (6 pages)
- Identifier: id-1216203
- Brand: Greenheck
- Device: Greenheck FSD-212 Fan
- Type: Operation & user’s manual, PDF
- Key Aspects: Environmental Factors and Restrictions, Error Code Explanations, Common Issue Diagnostic Flows
- UPD Date: 02.09.2026
- Source File: 942070.pdf
- Pages: 6
- Description: Installation and maintenance guide for the Greenheck FSD-212.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Installation instructions available at www.greenheck.com. Model FSD-212 Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage ClassII UL 555 1 1/2 Hour Fire Resistance Rating Application Model FSD-212 is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage in either direction. The FSD-212 may be installed vertically (with blades running horizontal) or horizontally. Ratings UL 555 Fire Resistance Rating Fire Rating: 11⁄2 hours Dynamic Closure Rating: Actual ratings are size dependent Velocity: Up to 2,000 fpm (10.2 m/s) Pressure: Up to 6 in. wg (1.5 kPa) UL 555S Leakage Rating Leakage Class: II Operational Rating: Actual ratings are size dependent Velocity: Up to 2,000 fpm (10.2 m/s) Pressure: Up to 6 in. wg (1.5 kPa) Temperature: Up to 350°F (177°C) - depending upon the actuator Construction Standard Optional Frame Material Galvanized steel - Frame Material Thickness 16 ga. (1.5mm) - Frame Type 5 in. x 1in. (127mm x 25mm) hat channel - Blade Material Galvanized steel - Blade Material Thickness 16 ga. (1.5mm) - Blade Type 3V - Linkage Plated steel out of airstream, concealed in jamb - Axle Bearings 304SS - Axle Material Plated steel - Blade Seals Silicone - Jamb Seals 304SS - Closure Device RRL RRL/OCI, TOR, PRV, or Fusible Link Closure Temperature 165°F (74°C) 212°F (100°C), 250°F (121°C), 350°F (177°C) Features: • Frames are constructed with reinforced corners. Low profile head and sill are used on sizes less than 17 in. high (432mm). • Blades are a double skin airfoil with full length structural reinforcement. *Width and Height dimensions furnished approximately 1⁄4 in. (6mm) undersize. Add sleeve thickness for overall sleeved damper dimension. See complete marking on product. UL 555 and UL 555S Classification R13317 Model FSD-212 meets the requirements for fire dampers, smoke dampers and combination fire smoke dampers established by: National Fire Protection Association NFPA Standards 80, 90A, 92A, 92B, 101 & 105 IBC International Building Codes CSFM California State Fire Marshal Fire Damper Listing (#3225-0981:103) Leakage (Smoke) Damper Listing (#3230-0981:104) New York City (MEA listing #260-91-M) W x H Minimum Size Maximum Size Single Section Multiple Section Horizontal Vertical 4 in. wg (1 kPa) pressure Inches 8 x 6 32 x 50 or 36 x 48 144 x 96 128 x 100 mm 203 x 152 813 x 1270 or 914 x 1219 3658 x 2438 3251 x 2540 6 in. wg (1.5 kPa) pressure Inches 8 x 6 36 x 48 144 x 48 128 x 48 mm 203 x 152 914 x 1219 3658 x 1219 3251 x 1219
Greenheck FSD-212 Installation, operation and maintenance instructions [PDF] (8 pages)
- Identifier: id-1490688
- Brand: Greenheck
- Device: Greenheck FSD-212 Fire and Smoke Dampers
- Type: Installation, operation and maintenance instructions, PDF
- Key Aspects: Unpacking and Inspection Guidelines, Operational Mode Explanations, Best Practices for Everyday Use
- UPD Date: 13.04.2026
- Source File: 1507741.pdf
- Pages: 8
- Description: Detailed product documentation for the Greenheck FSD-212.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
InstallatIon supplements Refer to the appropriate Greenheck installation supplements for special requirements: • Shaftwall Supplement • Drywall Supplement • Wood Supplement • Smoke Detector Supplement • Tunnel Corridor Supplement • Single Side Retaining Angle Supplement • Grille Installation Supplement • Field Installed Sleeve Supplement Installation,Operation and Maintenance Instructions for FsD-xxx, DFD-xxx,DFDtF-xxx CFsD-xxx,seDFD-xxx, seFsD-xxx, Imo-xxx, anD ssFsD-xxx serIes 1 1⁄2 and 3 Hour Fire & Combination Fire smoke Dampers (with factory installed sleeve and actuator) Vertical and Horizontal mount part #461336 saFety WarnInG: Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. This manual is the property of the owner, and is required for future maintenance. Please leave it with the owner when the job is complete. Typical Actuator RRL Control Device Standard Warranty Greenheck warrants this equipment to be free from defects in material and workmanship for a period of one year from the purchase date. Any units or parts which prove to be defective during the warranty period will be repaired or replaced at our option. Greenheck shall not be liable for damages resulting from misapplication or misuse of its products. Greenheck will not be responsible for any installation or removal costs. Greenheck will not be responsible for any service work or backcharges without prior written authorization. Due to continuing research, Greenheck reserves the right to change specifications without notice. “ul ClassIFIeD (see complete marking on product)” “ul ClassIFIeD to Canadian safety standards (see complete marking on product)” UL Standard 555 & 555S (Classification #R13317) FSD-XXX, SEFSD-XXX, SSFSD-XXX, DFD-XXX, SEDFD-XXX, and CFSD-XXX Series Dampers are intended for installation in accordance with combination fire smoke damper requirements established by: national Fire protection association NFPA Standards 90A, 92A, 92B & 101 BoCa national Building Codes ICBo uniform Building Codes IBC International Building Codes sBCCI standard Building Codes new york City (MEA listing #260-91-M) California state Fire marshal (Listing #3225-0981:103) and (Listing #3230-0981:104) - FSD models; (Listing #3225- 0981:103) - DFD models; (Listing #3230-0981:105) and (Listing 3225-0981:106) - CFSD models; (Listing #3225-0981:109) and (Listing 3230-0981:110 ) - SSFSD models reCeIVInG anD HanDlInG Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Dampers must be kept dry and clean. Indoor storage and protection from dirt, dust and the weather is highly recommended. Do not store at temperatures in excess of 100°F.
Similar Manuals in the Fan, Fire and Smoke Dampers Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
mercor mcr FID S c/P Series |
#F3N2V4: mcr FID S c/P Series Fire and Smoke Dampers Operation and maintenance manual |
18 | 1359 | 245 | 21-05-2026 | view all manuals | |
mercor mcr FID B |
mercor mcr FID B User Guide (Operation and maintenance manual), @4G9QI5 |
22 | 623 | 100 | 20-05-2026 | view all manuals | |
Mandik FDMB |
Mandik Fire and Smoke Dampers Manual (File: PDF, 25-05-2026) |
76 | 1270 | 229 | 25-05-2026 | view all manuals | |
SystemAir SAVE VTC 700 |
PDF Manual (@SNPJ2J), SystemAir SAVE VTC 700 Fan (20-07-2026) |
16 | 869 | 174 | 20-07-2026 | view all manuals | |
NuTone RDM2 |
NuTone Fire and Smoke Dampers Installation manual (File: PDF, 20-04-2026) |
20 | 263 | 53 | 20-04-2026 | view all manuals | |
Swegon actionair FireShield |
Swegon Fire and Smoke Dampers Manual (File: PDF, 15-06-2026) |
4 | 711 | 136 | 15-06-2026 | view all manuals |