Installation, Commissioning & Operating Manual 12 ZONE FULLY FUNCTIONAL REPEATER PANEL Approved Document UI-ASP-R-01 Issue 3.0 REPEATER PANEL IMPORTANT NOTE PLEASE READ THIS MANUAL BEFORE HANDLING THE EQUIPMENT AND OBSERVE ALL ADVICE GIVEN IN IT THIS PARTICULARLY APPLIES TO THE PRECAUTIONS NECESSARY TO AVOID E.S.D The panel is safe to operate provided it has been installed in compliance with the manufacturer’s instructions and used in accordance with this manual. Hazardous voltages are present inside the panel—DO NOT open it unless you are qualified and authorised to do so. There is no need to open the panel’s enclosure except to carry out commissioning, maintenance and remedial work. This work must only be carried out by competent service personnel who are fully conversant with the contents of the panel’s installation manual and have the necessary skills for maintaining this equipment. This fire alarm system requires periodic checks as specified in BS 5839 Part 1 It is the responsibility of the system user to ensure it is regularly serviced and maintained in good working order. Disclaimer No responsibility can be accepted by the manufacturer or distributors of this fire alarm panel for any misinterpretation of an instruction or guidance note or for the compliance of the system as a whole. The manufacturer’s policy is one of continuous improvement and we reserve the right to make changes to product specifications at our discretion and without prior notice. E & O E. IMPORTANT SAFETY NOTES Haes Systems Ltd, Columbia House, Packet Boat Lane, Cowley Peachey, Uxbridge, UB8 2JP Model Number AlarmSense PLUS 12 zone repeater panel ASP-R-12 European Standard EN54-2 : 1997 + A1 : 2006 Control and indicating equipment for fire detection and fire alarm systems for buildings. European Standard EN54-4 : 1997 + A1 : 2002 + A2 : 2006 Power supply equipment for fire detection and fire alarm systems for buildings. ATTENTION ASP-R Installation, Commissioning & Operating Manual Approved Document Ref: UI-ASP-R-01 Issue 3.0 1 CONTENTS Page ABOUT THIS PANEL 2 PRODUCT OVERVIEW 2 CABINET DETAILS 3 CIRCUIT BOARDS 4 MAIN PCB TERMINALS 5 COMMS PCB TERMINALS 5 TECHNICAL SPECIFICATION 6 POWER SUPPLY MODULE 7 INSTALLATION 8 SAFETY 8 ESD PRECAUTIONS 9 GENERAL 9 MOUNTING THE CABINET 9 MAINS CONNECTIONS 10 CONNECTING THE BATTERIES 11 CABLING 12 SETUP & PROGRAMMING 14 INSTALL COMMS PCB 14 SET NUMBER OF REPEATER PANELS 16 REPEATER PANEL ADDRESSING 16 PROGRAMMING REPEATER PANELS 17 OPERATING 18 PANEL CONTROLS & INDICATIONS 18 DISABLE MODE 20 TEST MODE 21 ASP-R Installation, Commissioning & Operating Manual Approved Document Ref: UI-ASP-R-01 Issue 3.0 2 ABOUT THIS PANEL PRODUCT OVERVIEW The AlarmSense PLUS repeater panels have the same, easy to use, controls and indications as the main control panel but mounted in a smaller cabinet. The repeaters are fully functional with ‘Silence’, ‘Resound’ and ‘Reset’ controls, as well as Disable and Test Mode functions. AlarmSense PLUS panels can support up to 8 repeater panels. Repeater panels are designed to be wired in a fault tolerant (fail safe) loop configuration, from comms A to B and back to the main panel again. This enables repeater panels to still work if there is a break in the cables. If replacing an older system where the existing cabling cannot be configured in a loop as above, it is possible to re-programme the panel back to legacy RS485 circuit comms monitoring. This then allows any topology of comms cabling to be utilised. The main circuit board has 2, switch –ve, inputs which can be used to sound or pulse the alarms. These inputs can also be re-programmed for use as PSU fault inputs. The internal comms PCB has 6, switch –ve, programmable outputs. Different key types are used for the door lock and the ‘activate controls’ key-switch. It is also possible to enable the controls via a 4 digit code entry if preferred. An eight button keypad is used to control the system and allow access to the function options (unless disabled). The control panel comprises of a sheet steel enclosure suitable for wall mounting with a hinged, lockable front access door. It can be semi recessed, using a suitable recessing bezel. Cable entry is via 20mm ‘knockouts’ located at the top and rear of the cabinet. The repeaters are supplied with a 1.5 amp internal power supply module. This module complies with the requirements of EN54-4 : 1988 and provides temperature compensated battery management charging. Quiesecent and alarm current details for standby battery calculations Standby Current Alarm Current ASP-R-12 repeater panel 63mA 85mA
Haes ESENTO MARINE ESEN-R-12MAR Installation, commissioning & operating  manual Main Page Preview

Installation, commissioning & operating manual [PDF] (24 pages)

  • Brand: Haes
  • Model: ESENTO MARINE ESEN-R-12MAR
  • Format: PDF
  • Key Aspects: Package Contents and Accessories List, Component Overview and Descriptions, Additional Modules and Accessories Guide
  • Updated: 27.08.2026
  • Source File: 2294903.pdf
  • Pages: 24
  • Description: Step-by-step guide for the Haes ESENTO MARINE ESEN-R-12MAR.

Document Preview & Text Transcription

Installation, Commissioning & Operating Manual 12 WAY FULLY FUNCTIONAL/PASSIVE REPEATER PANEL Approved Document UI-ESEN-RMAR-01 Issue 5.0 REPEATER PANEL MED Ref: 0832/15 IMPORTANT NOTE PLEASE READ THIS MANUAL BEFORE HANDLING THE EQUIPMENT AND OBSERVE ALL ADVICE GIVEN IN IT THIS PARTICULARLY APPLIES TO THE PRECAUTIONS NECESSARY TO AVOID E.S.D The panel is safe to operate provided it has been installed in compliance with the manufacturer’s instructions and used in accordance with this manual. Hazardous voltages are present inside the panel—DO NOT open it unless you are qualified and authorised to do so. There is no need to open the panel’s enclosure except to carry out commissioning, maintenance and remedial work. This work must only be carried out by competent service personnel who are fully conversant with the contents of the panel’s installation manual and have the necessary skills for maintaining this equipment. This fire alarm system requires periodic checks as specified in BS 5839 Part 1 It is the responsibility of the system user to ensure it is regularly serviced and maintained in good working order. Disclaimer No responsibility can be accepted by the manufacturer or distributors of this fire alarm panel for any misinterpretation of an instruction or guidance note or for the compliance of the system as a whole. The manufacturer’s policy is one of continuous improvement and we reserve the right to make changes to product specifications at our discretion and without prior notice. E & O E. IMPORTANT SAFETY NOTES Haes Technologies Ltd, Unit 3, Horton Industrial Park, West Drayton, UB7 8JD Model Number MED Ref No. Esento Marine 12 way repeater panel ESEN-R-12MAR 0832-MED-1086 ATTENTION European Standard EN54-2 : 1997 + A1 : 2006 Control and indicating equipment for fire detection and fire alarm systems for buildings. Provided Options (with requirements): Output to fire alarm devices, dependency type ‘A’, test condition European Standard EN54-4 : 1997 + A1 : 2002 + A2 : 2006 Power supply equipment for fire detection and fire alarm systems for buildings. European Standard BS IEC60092-504 : 2001 Electrical installations in ships, special features, control and instrumentation. European Standard BS IEC60533 : 1999 Electrical and electronic installations in ships, electromagnetic compatibility. ESEN-RMAR Installation, Commissioning & Operating Manual Approved Document Ref: UI-ESEN-RMAR-01 Issue 5.0 1 CONTENTS Page ABOUT THIS PANEL 2 PRODUCT OVERVIEW 2 CABINET DETAILS 3 CIRCUIT BOARDS 4 MAIN PCB TERMINALS 5 COMMS PCB TERMINALS 5 TECHNICAL SPECIFICATION 6 POWER SUPPLY MODULE 7 INSTALLATION 8 SAFETY 8 ESD PRECAUTIONS 9 GENERAL 9 MOUNTING THE CABINET 9 MAINS CONNECTIONS 10 CONNECTING THE BATTERIES 11 CABLING 12 SETUP & PROGRAMMING 14 INSTALL COMMS PCB IN MAIN CONTROL PANEL 14 SET NUMBER OF REPEATER PANELS (ON MAIN CONTROL PANEL) 15 REPEATER PANEL ADDRESSING 15 PROGRAMMING REPEATER PANELS 16 REPEATER MIMIC DSPLAY MODE 17 OPERATING 18 PANEL CONTROLS & INDICATIONS 18 DISABLE MODE 20 TEST MODE 21