1 6E 6360.c 6E 6360.c § 2 channel programmer annual and weekly cycle User instructions Navigation & value setting Validation Enter in PROGRAMME mode & return to previous step Selection of days of the week 1 = Monday, 2 = Tuesday ... 7 = Sunday Canal B command Canal A command Keyboard locked by PIN code menu + ok At any time, pressing the button menu allows you to return to the previous choice level. Programming To do the yearly programming of the clock, you have the following 4 types of programme : - Basic weekly programme This is a non-priority weekly programme. - Sub-programmes 1 to 10 These are weekly sub-programmes which are activated for a defined date-to-date period. As the sub-programme number increases, so does the priority. - DATE/TIME This is a programme step composed of a time and a date which will run in addition to the usual programme. If there is conflict between this programme step and another programme step (SP or weekly), this step has priority. - Holidays This programme allows you to define a permanent ON or OFF from date-to-date. This programme has the highest priority. Product Presentation Connection diagram A B 1 3 5 2 4 6 8 10 12 14 16 11 13 15 7 9 L N EG293B Menu Press the button menu to access the programming/ setting mode. All of the programming and adjustments are based on the following principle : - the 1st line and/or 2nd line of the display indicate the requested setting, - the buttons +/- allow navigation through the menus and settings, - the button ok allows validation. Pressing the button menu allows you to access the following settings : PROGRAM SETTINGS FUNCTIONS DATE-TIME S/W TIME LANGUAGE FACTORY SETTINGS BACK AUTO PROGRAM CREATE PROGRAM READ PROGRAM MODIFY PROGRAM DELETE PROGRAM COPY BACK AUTO COUNTER CYCLE PIN CODE INPUT BACK AUTO menu Electrical characteristics ⦁Supply voltage: 230 V +10/-15% ⦁Frequency: 50/60 Hz ⦁Power consumption : < 2 VA ⦁Output : 2 changeover contacts ⦁Maximum load : AC1 μ 10A 250 V~ Incandescent lighting : 1500 W Halogen lighting : 230 V 1500 W Compensated fluorescent tubes // : (max. 45 μF) 400 W Non compensated fluorescent tubes, compensated in series : 1000 W Compact fluorescent lamps : 400 W ⦁Minimum load AC1 100 mA 250 V~ ⦁Galvanic insulation between power supply and output < 4 kV Technical specifications Functional characteristics ⦁Programming capacity : 300 steps ⦁Minimum time between 2 steps : 1 minute ⦁Running accuracy : ± 0,2 sec/ 24h ⦁Operating reserve : lithium battery, total of 5 years autonomy (unlimited programme backup) ⦁The product is set into standby state (display switched-off) after 1 minute with power off. It switches back into automatic mode as soon as power is back on or when pressing any key. ⦁Protection degree : IP 20 / IK 04 Environment ⦁Operating temperature : -10 °C to +50 °C ⦁Storage temperature : -20 °C to +70 °C Connection by quick-connect terminals ⦁Flexible : 0,75 to 2,5 mm2 ⦁Rigid : 0,75 to 2,5 mm2 Presentation ⦁Product delivered with current time and date set. ⦁Automatic change of summer/winter time. ⦁Programming key - For permanent overrides - For program copy or save ⦁300 programme steps ; ON, OFF, pulses or . ⦁Permanent overrides On or Off ( permanent light on). ⦁Temporary overrides On or Off ( flashing). ⦁Overrides (temporary, permanent or time delayed) remote activation possible. ⦁Simulation of presence . ⦁Keyboard lock function by PIN number. ⦁Counter of operating time on every output. ⦁Programmable with power off. ⦁Display with backlight. When using for the first time, the following settings must be done : - select the language - select the year, month, day - select the hour and the minutes - select the automatic change summer/winter. Press the buttons +/– to set the display. Press OK to validate. When the settings are finished, the clock goes to automatic mode. First commissioning * * Input for external override Pressing simultaneously the menu, –, +, ok keys allows you to réinitialize the product. The program is kept in memory. Reinitializing Creating a holiday programme The Holiday programme allows you to define one or several periods during which the output contact is on ON or OFF. This programme has the highest priority. To define your Holiday programme : To visualise a programme To check the steps of the recorded programme without risk of modifying or deleting. Creating a specific programme step (day-time) : A specific programme step is a programme step composed of a switching time and a date. This happens in addition to the weekly programme type or the sub-programme. If there is conflict, this has priority. PROGRAMME READ HOLIDAYS DAY/TIME SP1 - SP10 WEEKLY HOLIDAYS DATE/TIME SP1 - SP10 WEEKLY BACK AUTO DELETE MODIFY HOLIDAYS OFF NOT REPEATED VARIABLE DATE HOLIDAYS ON FIX DATE 14.07 - 03.08 HOLIDAYS CONTINUE PROGRAM START MONTH 01.07 START DAY 14.07 END MONTH 01.08 END DAY 03.08 DATE/TIME CYCLE DATE/TIME IMPULSE DATE/TIME OFF NOT REPEATED KEEP DAYWEEK BACK AUTO DELETE MODIFY DATE/TIME ON FIX DATE 07:00 CONTINUE PROGRAM EX 03.03 ON 07:00 SET HOUR 00:00 SET MINUTES 00:00 SET MONTH 00:00 SET DAY 00:00 Select : - fixed dates : if the programme must be repeated every year at the same dates. - KEEP DAY WEEK : if the dates must be recalculated every year in order to occur on the same day of the week. - NOT REPEATED : if the programme is to be activated once only. Validate by ok. Select : - FIX DATE : if the programme must be repeated every year at the same dates. - VARIABLE DATE ( ) if the dates must be recalculated every year according to the dates of Easter. - NOT REPEATED : if the programme is to be activated once only. Validate by ok. 1.Define the weekly programme Creating a sub-programme (SP1-10) : Two phases are necessary to create a sub- programme : Define the weekly programme. Define the period when the programme will be active. Creating the basic weekly programme: CYCLE FUNCTIONS SETTINGS CHANNEL B HOLIDAYS DAY/TIME SP1 - SP10 IMPULSE OFF NO MONDAY BACK AUTO DELETE MODIFY PROGRAM COPY PROGRAM DELETE PROGRAM MODIFY PROGRAM READ PROGRAM CREATE CHANNEL A WEEKLY PROGRAM ON YES MONDAY SUNDAY SET MINUTE 00:00 ON 07:00 CONTINUE PROGRAM SET HOUR 00:00 menu HOLIDAYS DAY/TIME SP1 - SP10 SP ACTIVATE WEEKLY SP PROGRAM BACK AUTO DELETE MODIFY SUNDAY SET MINUTE 00:00 SP01 ON 07:00 CONTINUE PROGRAM SET HOUR 00:00 PROGRAM CREATE PROGRAM FUNCTIONS SETTINGS PROGRAM menu * *The cycle programme is only possible if one or several cycles have been defined in the FUNCTION/CYCLE menu. SP ACTIVATE SP01 IMPULS SP01 OFF NO MONDAY SP NUMBER 10 SP NUMBER ... SP NUMBER 02 SP PROGRAM SP NUMBER 01 SP01 ON YES MONDAY SUNDAY Select : - fixed dates : if the programme must be repeated every year at the same dates. - variable date ( ) if the dates must be recalculated every year according to the dates of Easter. - NOT REPEATED : if the programme is to be activated once only. Validate by ok. 2.Activate the sub-programme. To define the start and end of activation dates of the sub-programme : SP ACTIVATE BACK AUTO DELETE MODIFY SP NUMBER 10 SP NUMBER ... SP NUMBER 02 NOT REPEATED VARIABLE DATE SP PROGRAM SP NUMBER 01 FIX DATE 28.01 - 14.02 SP1 CONTINUE PROGRAM START MONTH 01.01 START DAY 28.01 END MONTH 01.02 END DAY 14.02 HOLIDAYS DAY/TIME SP1 - SP10 WEEKLY A sub-programme can be attributed to several different periods. When the start date and the end date are identical, the sub-programme is only valid for that day. If several programmes are activated in the same time, at the same date, the programme with the highest number (eg. Pg 10) is the one that will be activated. The other sub-progammes will be cancelled. EG293B http://waterheatertimer.org/Hagar-timers-and-manuals.html _________________________________________________________________________
hager EG293B User instructions [PDF] (4 pages)
- Identifier: id-2183041
- Brand: hager
- Device: hager EG293B Motherboard
- Type: User instructions, PDF
- Key Aspects: Pre-Installation Safety Requirements, Device Specifications Overview, Safety Recommendations and Warnings
- UPD Date: 26.08.2026
- Source File: 2104593.pdf
- Pages: 4
- Description: Operating instructions for the hager EG293B.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 6E 6360E 6E 6360E § 2 channel programmer annual and weekly cycle User instructions Navigation & value setting Validation Enter in PROGRAMME mode & return to previous step Selection of days of the week 1 = Monday, 2 = Tuesday ... 7 = Sunday Canal B command Canal A command Keyboard locked by PIN code menu + ok At any time, pressing the button menu allows you to return to the previous choice level. Programming To do the yearly programming of the clock, you have the following 4 types of programme: - Basic weekly programme This is a non-priority weekly programme. - Sub-programmes 1 to 10 These are weekly sub-programmes which are activated for a defined date-to-date period. As the sub-programme number increases, so does the priority. - DATE/TIME This is a programme step composed of a time and a date which will run in addition to the usual programme. If there is conflict between this programme step and another programme step (SP or weekly), this step has priority. - Holidays This programme allows you to define a permanent ON or OFF from date-to-date. This programme has the highest priority. Product Presentation Connection diagram A B 1 3 5 2 4 6 8 10 12 14 16 11 13 15 7 9 L N EG293B Menu Press the button menu to access the programming/ setting mode. All of the programming and adjustments are based on the following principle: - the 1st line and/or 2nd line of the display indicate the requested setting, - the buttons +/- allow navigation through the menus and settings, - the button ok allows validation. Pressing the button menu allows you to access the following settings: PROGRAM SETTINGS FUNCTIONS DATE-TIME S/W TIME LANGUAGE FACTORY SETTINGS BACK AUTO PROGRAM CREATE PROGRAM READ PROGRAM MODIFY PROGRAM DELETE PROGRAM COPY BACK AUTO COUNTER CYCLE PIN CODE INPUT BACK AUTO menu Electrical characteristics ⦁Supply voltage: 230 V +10/-15% ⦁Frequency: 50/60 Hz ⦁Power consumption: < 2 VA ⦁Output : 2 changeover contacts ⦁Maximum load: AC1 µ 10A 250 V~ Incandescent lighting: 1500 W Halogen lighting: 230 V 1500 W Compensated fluorescent tubes // : (max. 45 µF) 400 W Non compensated fluorescent tubes, compensated in series: 1000 W Compact fluorescent lamps: 400 W ⦁Minimum load: AC1 100 mA 250 V~ ⦁Galvanic insulation between power supply and output: < 4 kV ⦁Rated impulse voltage: 4 kV Technical specifications Functional characteristics ⦁Programming capacity: 300 steps ⦁Minimum time between 2 steps: 1 minute ⦁Running accuracy: ± 0,2 sec/ 24h ⦁Operating reserve: lithium battery, total of 5 years autonomy (unlimited programme backup) ⦁The product is set into standby state (display switched-off) after 1 minute with power off. It switches back into automatic mode as soon as power is back on or when pressing any key. ⦁Protection degree: IP 20 / IK 04 ⦁Action type : 1B ⦁Degree of pollution : 2 ⦁Software class: A Environment ⦁Operating temperature: -10 °C to +50 °C ⦁Storage temperature: -20 °C to +70 °C ⦁Temperature for the ball pressure Test: 75° to 125°C Connection by quick-connect terminals ⦁Flexible: 0,75 to 2,5 mm2 ⦁Rigid : 0,75 to 2,5 mm2 Standards 60730-1 60730-2-7 Presentation ⦁Product delivered with current time and date set. ⦁Automatic change of summer/winter time. ⦁Programming key - For permanent overrides - For program copy or save ⦁300 programme steps ; ON, OFF, pulses or . ⦁Permanent overrides On or Off ( permanent light on). ⦁Temporary overrides On or Off ( flashing). ⦁Overrides (temporary, permanent or time delayed) remote activation possible. ⦁Simulation of presence . ⦁Keyboard lock function by PIN number. ⦁Counter of operating time on every output. ⦁Programmable with power off. ⦁Display with backlight. * * Input for external override Pressing simultaneously the menu, –, +, ok keys allows you to réinitialize the product. The program is kept in memory. Reinitializing EG293B When using for the first time, the following settings must be done: - select the language - select the year, month, day - select the hour and the minutes - select the automatic change summer/winter. Press the buttons +/– to set the display. Press OK to validate. When the settings are finished, the clock goes to automatic mode. First commissioning § Warranty NOT APPLICABLE FOR AUSTRALIA A warranty period of 24 months is offered on hager products, from date of manufacture, relating to any material of manufacturing defect. If any product is found to be defective it must be returned via the installer and supplier (wholesaler). The warranty is withdrawn if: - after inspection by hager quality control dept the device is found to have been installed in a manner which is contrary to IEE wiring regulations and accepted practice within the industry at the time of installation. - The procedure for the return of goods has not been followed. Explanation of defect must be included when returning goods. This device must be installed only by a qualified electrician according to the installation standards in force in the country. Usable in all Europeå and in Switzerland
Similar Manuals in the Motherboard, Timer Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Foxconn 720A |
720A (Motherboard ePDF User Manual, #35OTP9) |
112 | 8.67 Mb | 664 | 127 | 18-05-2026 | view all manuals |
SOYO 6KME |
PDF User Manual (@Q1D868), SOYO 6KME Motherboard (23-08-2026) |
46 | 0.27 Mb | 43 | 11 | 23-08-2026 | view all manuals |
Analog Devices EVAL-ADM2482EEB3Z |
EVAL-ADM2482EEB3Z Operation & user’s manual - O3D359 |
12 | 115 | 20 | 04-04-2026 | view all manuals | |
MSI Z87-G43 GAMING |
Z87-G43 GAMING Operation & user’s manual - 15S854 |
110 | 1449 | 261 | 18-07-2026 | view all manuals | |
VersaLogic Lion |
VersaLogic Lion Guide (Bios reference manual), @8732N7 |
77 | 1102 | 265 | 19-06-2026 | view all manuals | |
Viglen Vig711W |
Viglen Vig711W User Manual (Manual ), @12NZU6 |
51 | 424 | 73 | 16-07-2026 | view all manuals |