hager TX 206A Manuals
1 pdf manual(s) hager TX 206A for free download (Document Types: Quick start manual)
hager TX 206A Quick start manual [PDF] (4 pages)
- Identifier: id-1506570
- Brand: hager
- Device: hager TX 206A Switch
- Type: Quick start manual, PDF
- Key Aspects: Package Contents and Accessories List, Unpacking and Inspection Guidelines, Model Variations and Compatibility
- UPD Date: 16.06.2026
- Source File: 1491859.pdf
- Pages: 4
- Description: User guide for the hager TX 206A.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
F GB D NL I F 1 6T 7208.a 6T 7208.a E S P N D GB µ4 A 230 V� auto TX 206A 4 6 Module de sortie 6 contacts Schaltausgang 6 Schließer Switch output 6 contacts Uitgangsmodule 6 kontakten Modulo di uscita 6 contatti Die Steuergeräte mit 6 Ausgängen TX206 fungieren als Schnittstelle zwischen dem EIB/KNX-Bus und im Modus „Alles oder Nichts“ elektrisch angesteuerten Lasten. Diese Geräte gehören zum Tebis-Installations- System. Insbesondere dienen sie zur Steuerung der Beleuchtung bzw. der Heizung (Heizkörper oder Elektro-Thermostatventile) oder sonstiger über spannungsfreie Kontakte gesteuerter Lasten. Diese Geräte existieren in 3 Ausführungen, die sich nur durch die Leistung der anzuschließen- den Lasten unterscheiden. Einstellungen ● TX 100 : Ausführliche Beschreibung in der mit dem Konfigurationsgerät mitgelieferten Bedienungsanleitung. ● ETS : Anwendungssoftware TL206. Datenbank und Beschreibung beim Hersteller erhältlich. Funktionen ● 6 unabhängige Kanäle, Ansteuerung über EIB/KNX-Bus ● 6 spannungsfreie Kontakte ● Zustandsanzeige der Ausgänge am Gerät. ● Möglichkeit zur manuellen Ansteuerung der Ausgänge über das Gerät gegeben. Die genauen Funktionen dieser Geräte hängen von der jeweiligen Konfiguration und den jeweiligen Parametereinstellungen ab. Anschluß, Test, Inbetriebnahme In der Stellung „Manu“ des Umschalters ➀, dienen die Taster ➄ zur Ansteuerung der an die Ausgänge angeschlossenen Lasten. Die LEDs ➃ zeigen den Zustand der entsprechenden Ausgangsrelais an: LED leuchtet = Relais geschlossen. In der Stellung „Auto“ des Umschalters sind die Taster ➄ deaktiviert. Die Relais werden über den Bus angesteuert. Die LEDs ➃ zeigen den Zustand Achtung: - Einbau und Montage dürfen nur durch eine Elektrofachkraft erfolgen. - Installationsvorschriften zur Schutzmaßnahme SELV beachten. der Ausgangsrelais an. Die physikalische Adressierung erfolgt anhand von Taster ➁ und LED ➂. Das Anliegen des BUSSES wird durch das Aufleuchten der LED ➂ nach Betätigung des Tasters ➁ angezeigt. Das Blinken aller LEDs ➃ zeigt die Ladung einer falschen Anwendungssoftware an. Die Konfiguration ist nur möglich, wenn der Umschalter ➀ in Stellung „Auto“ steht. Die physikalische Adressierung erfolgt anhand von Taster ➁ und LED ➂. Die Ausgänge können über unterschiedliche Phasen gespeist werden. The 6-output drivers TX206 are relays used to interface the EIB/KNX Bus with electrical loads controlled in go-no-go mode. They are part of the Tebis installation system. They can be used to control lighting, heating (convector, thermoelectric valves, or any other load controlled by a contact free of potential). Three different models are available according to the power of connectable loads. Configuration ● TX 100 : A description is included in the note supplied with the configurer . ● ETS : Application software TL206. The database and description are available from the manufacturer. Functions ● 6 independent channels controlled by bus EIB/KNX. ● 6 contacts free of potential. ● Display of output state on the product . ● The manual control of the outputs is possible from the product . The particular functions of each product depend on the configuration and the set-up. Wiring, test, startup With switch ➀ in Manu position, BP ➄ can control the loads connected to the outputs. LEDs ➃ indi- cate the state of the corresponding output relays: ON = closed relay. When set in Auto position, BPs ➄ are inactive. The relays are controlled from the bus. LEDs ➃ indicate the state of output relays. Pushbuttons ➁ and LED ➂ control the physical addressing of the product. LED ➂ switches on after pressing ➁ and indicates the presence of the BUS. Caution : - This device must be installed only by a qualified electrician. - Conform to TBTS installation rules. The flickering of all LEDs ➃ indicates loading of wrong software. Configuring is possible only when switch ➀ is in Auto position. Physical addressing is done using BP ➁ and LED ➂. Outputs can be supplied by different phases. Les pilotes 6 sorties TX206 sont des relais permettant d’interfacer le Bus EIB / KNX avec des charges électriques commandées en tout ou rien. Ils font partie du système d’installation Tebis. En particulier, ils permettent de commander de l’éclairage, du chauffage (convecteur ou vannes électrothermiques, ou toute autre charge commandée par un contact libre de potentiel. Ces produits existent en 3 variantes qui ne se distinguent que par la puissance des charges raccordables. Configuration ● TX 100 : description détaillée dans la notice livrée avec le configurateur. ● ETS : logiciel d’application TL 206 : base de données et descriptif disponibles chez le constructeur. Fonctions ● 6 voies indépendantes commandées par le bus EIB/KNX ● 6 contacts libres de potentiel. ● Visualisation de l’état des des sorties sur le produit. ● Possibilité de commande manuelle des sorties à partir du produit. Les fonctions précises de ces produits dépendent de la configuration et du paramétrage. Câblage, test et mise en route En position manu du commutateur ➀, les BP ➄ permettent de commander les charges raccordées aux sorties. Les LED ➃ indiquent l’état des relais de sortie correspondants : Allumé = relais fermé. En position Auto, les BP ➄ sont inactifs. Les relais sont commandés à partir du bus. Les LED ➃ indiquent l’état des relais de sortie. Le bouton poussoirs ➁ et la Led ➂ permettent Attention : - Appareil à installer uniquement par un installateur électricien. - Respecter les règles d’installation TBTS. l’adressage physique du produit. La présence du bus est signalée par l’allumage de la LED ➂ après appui sur le BP ➁. Le clignotement de toutes les LED ➃ indique le chargement d’un mauvais logiciel d’application. La configuration n’est possible qu’en position auto du commutateur ➀. L’adressage physique se fait à l’aide du BP ➁ et de la LED ➂. Les sorties peuvent être alimentées par des phases différentes. / RF tebis TP 230V~ Bus 29 V TX 206A : 6 x4 A TX 206B : 6 x10 A TX 206C : 6 x16 A TX 206D : 3x6 A + 3x16 A L N 1 3 7 9 13 15 8 10 14 5 11 6 12 16 µ4 A 230 V� auto TX 206A 4 6 ➄ ➀ ➂ ➁ BUS EIB ➃
Similar Manuals in the Switch Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Net2Edge Liberator 44 Series |
#RWYQ19: Liberator 44 Series Switch Installation manual |
65 | 1005 | 252 | 18-03-2026 | view all manuals | |
Avaya 5000 Series |
5000 Series (Switch ePDF Manual, #NZX5R4) |
101 | 1321 | 291 | 21-03-2026 | view all manuals | |
NETGEAR SB104 Network Starter Kit SB104 SB104 |
PDF Guide (@59YE4G), NETGEAR SB104 Network Starter Kit SB104 SB104 Switch (11-08-2026) |
2 | 1175 | 247 | 11-08-2026 | view all manuals | |
H3C S9500 Series |
S9500 Series (Switch ePDF Manual, #KCKD38) |
13 | 1133 | 272 | 04-05-2026 | view all manuals | |
Encore ENH905-NWY |
Encore Switch Specifications (File: PDF, 22-04-2026) |
2 | 0.07 Mb | 935 | 206 | 22-04-2026 | view all manuals |
Hama 00053180 |
PDF User Guide (@NT9RT4), Hama 00053180 Switch (07-07-2026) |
14 | 1348 | 257 | 07-07-2026 | view all manuals |