hager WUT09 Manuals

2 pdf manual(s) hager WUT09 for free download (Document Types: Manual )

hager WUT09 Manual  [PDF] (2 pages)

  • Identifier: id-825998
  • Brand: hager
  • Device: WUT09 Controller
  • Type: PDF
  • Key Aspects: Control Panel and Interface Navigation, Hardware Setup Instructions, Error Code Explanations
  • UPD Date: 26.06.2026
  • Source File: 813764.pdf
  • Pages: 2
  • Description: Setup and usage guide for the hager WUT09.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 05/2017 - 6LE003205A Hager Controls S.A.S., 33 rue Saint-Nicolas, B.P. 10140, 67703 SAVERNE CEDEX, France - www.hager.com WUT09 KNX room controller WUT08 KNX thermostat 6LE003205A 1,5m ϑ (15) (1) (2) (12) (16) (13) (14) (3) (4) A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 Config mode Settings language config mode factory reset 247 16:27 11.11.2015 Settings Settings device info setpoint heating internal sensor A12 θ A2-1 A8-1 B1 B2 B3 (13) (13) (2) (1) (2) (15) (14) (12) (16) (14) (14) (16) (16) (15) (13) (16) (14) (4) (3) (4) (3)

hager WUT09 Manual  [PDF] (2 pages)

  • Identifier: id-825999
  • Brand: hager
  • Device: WUT09 Controller
  • Type: PDF
  • Key Aspects: Best Practices for Everyday Use, Risk Mitigation and Accident Prevention, Troubleshooting Information
  • UPD Date: 21.08.2026
  • Source File: 813763.pdf
  • Pages: 2
  • Description: Professional operation guide for the hager WUT09.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 6LE000447C WUT08 KNX thermostat with display WUT09 KNX room controller with display z 02/2016 - 6LE000447C Hager S.A.S. - 132 bld d‘Europe - BP 78 - 67212 Obernai cedex (FRANCE) - Tel. +333 88 49 50 50 - www.hagergroup.com Safety instructions z Electrical equipment may only be installed and assembled by a qualified electrician. Always follow the relevant accident prevention regula- tions. Failure to comply with these installation in- structions may result in damage to the device, fire or other hazards. When installing and laying cables, always com- ply with the applicable regulations and stand- ards for SELV electrical circuits. The CE declaration of conformity of the KNX thermostat, KNX room controller has taken place in the Hager/Berker System. In this con- text, we can only guarantee complete safety and functionality if suitable power supplies are used (see Accessories, Technical Data). These instructions are an integral component of the product and must be retained by the end user. Design and layout of the device (2) (1) Figure 1: Front view Sensor 24V (5) (3) (4) Figure 2: Rear view (1) Touch-sensitive control surface (2) Display area (3) Connecting terminal auxiliary voltage 24 V SELV (4) KNX bus connection terminal (5) Connecting terminal of external temperature sensor (not in scope of delivery, enclosed with the temperature sensor) Function System information This device is a product of the KNX system and corresponds to the KNX guidelines. Detailed specialised knowledge obtained from KNX training courses is required for understanding. The plan- ning, installation and commissioning are carried out with the help of KNX-certified software. system link start-up The function of the device is software-depend- ent. The software is to be taken from the product database. You can find the latest version of the product database, technical descriptions as well as conversion and additional support programmes on our website. easy link start-up The function of the device is configuration-de- pendent. The configuration can also be done using devices developed specially for simple setting and start-up. This type of configuration is only possible with devices of the easy link system. easy link stands for easy, visually supported start-up. Preconfigured standard functions are assigned to the in/outputs by means of a service module. Correct use - Single room temperature control in KNX instal- lations - Installation into wall box according to DIN 49073 - Auxiliary voltage supply according to EN 61558 or in the context of the specifications (see Tech- nical data) Product characteristics - Start-up and programming in S-mode and E-mode - Measurement of the room temperature and comparison with set temperature - Touch-sensitive control surface - Setpoint specification by selecting the operating mode - Operating modes comfort, standby, economy mode, frost/heat protected, holiday mode - Heating and cooling mode - Ventilation function - Timer function - Display of statuses and power consumption - Push-button functions such as switching, dimming, blind/roller shutter etc. (only KNX room controllers) - Connection for external temperature sensor (see Accessories) Functional description The device compares the current room temperature with the set temperature and controls heating and cooling devices according to the current requirements. The heating system must also be suitable when used for heating or cooling mode. The set temperature is defined by the operating mode and can be changed via the menu operating mode - holiday mode or settings. The selected op- erating mode, current time and measured room tem- perature are indicated in the display as an example (figure 3). The display contents can be represented in different ways depending on the setting. The upper status line symbolically represents the status of the device currently set (6). Room controller variant The room controller also has push-button functions in addition to the thermostat. This allows e.g. lighting to be switched/dimmed or roller shutters/blinds to be moved. This first requires making settings in the ETS or service-module easy link. Up to 3 control surfaces can be freely configured for these functions per display page. A maximum of 9 functions are freely programmable. Operation Display elements and operating concept The display is subdivided into a display area and control surface. In the upper rows of the display (6) only symbols indicate the set/active parameters in the basic display. Below this e.g. the current room tem- perature (7), current display of an external tempera- ture sensor (11) and the current date or current time (10) are visualised in basic operation. In the setting mode, both areas are used for displaying possible selection and parameter values. The lower row of the display area (8) changes its dis- play depending on the menu item. Symbols indicate the active/inactive functions that can be triggered using the touch control surface (9) below. - Push button operation: Switching on/off, confirming or changing a function of a function parameter by pressing the respective touch control surface below the displayed symbols. - Slider operation: P By "swiping" from left to right or right to left over the touch-sensitive control surface it is possible to switch to the next/previous page, exit the current operating level or cancel the parameter entry/change. Operating a function or load Loads, such as lighting or blinds, are operated using the touch-sensitive control surface and is dependent on the device configuration. z Press a touch control surface (9) below the symbols (8). The stored function is executed. The actuation pulse lasts for the duration of the actuation. Depending on the function, short and long touches can trigger different actions, e.g. switching/dimming. Operation in the basic display The following functions are active in the basic display: / : Increase/decrease room temperature setpoint. The temperature can be varied between 7 ... 40°C for each operating mode.The display changes to red when the heating energy is supplied or to blue when cooled. Extension of the comfort operating mode. Display of comfort extension via . Or: / Change-over between comfort mode and economy mode. The functions for the basic display can be set and configured individually in the ETS. 24.7 16:27 -13.3°C (6) (7) (8) (9) (10) (11) °C Figure 3: Basic display (6) Status line with symbols (7) Current room temperature display (8) Display of the active functions (9) Touch-sensitive control surface (10) Display of date/time (11) Temperature display of the external tempera- ture sensor Setting the parameters and values z Change to the next/previous page by swiping your finger over the touch control surface (9). <<<< <<<< 24.7 16:27 -13.3°C °C Figure 4: Slider function By "swiping" your finger over the touch-sensi- tive control surface you cancel the parameter P P P P setting on each menu level and change to the next higher menu level. Pressing one of the three touch areas (figure 5) be- low the function symbols causes the corresponding function to be executed. 24.7 16:27 -13.3°C °C Figure 5: Touch areas of the touch control surface Menu Status - A1 The current state of the parameterised devices, such as window contact request, status of the connected loads, dewpoint operation, is displayed in the menu status. A symbol and the correspond- ing value display with unit can be assigned to the current status. Home status dew point active window is open Figure 6: Menu status Menu - A2 The menu allows you to reset the thermostat to one of the two last parameter settings saved (figure 7). If one of the last saved settings is selected, the current parameters in the device will be overwritten with the last settings saved. No problem Would you like to return to your settings of JJJJ/MM/DD Figure 7: Menu Settings menu - A3 In the settings menu, the basic functions and parameters of the device are to be set/changed manually. Settings setpoint heating device info setpoint cooling Figure 8: Settings menu z Select the parameter with / . z Confirm the selection with . P The selected parameter will open in a new screen. Setpoint heating: Setting of the temperature setpoint for the operat- ing modes Comfort, Standby and Night Reduction. Setpoint cooling: Setting of the temperature setpoint for the operat- ing modes Comfort, Standby and Night Reduction. Internal sensor: Parameter for setting the temperature adjust- ment with the temperature sensor in the device. External sensor: Parameter for setting the temperature adjust- ment with an external temperature sensor. Heating or cooling mode: Settings Heat/coo mode External senssor Date & Time Figure 9: Heating or cooling mode selection z Press touch control surface under . The operating mode (figure 9) changes from heating to cooling . In the function line (8) the inactive operating mode is displayed on the right, which can be activated using the control surface. Date/time: Date/time time 10:45 date 24 / 04 / 2014 Figure 10: Date/time setting Date and time are not set in the default state. The respective value selected can be changed (figure 10). z Increase/decrease numerical value with / . z Change to the next adjustable value with . At the last value to be set, the display changes from to . z Confirm the entry with . 24h/12h Time format 24 12h Settings time format date & time screen brightness h Figure 11: Time format setting z Press touch control surface under 12h for the 12h display. The time format changes from the 24h to 12h display. In the function line (8) the 24h appears in order to switch back again to 24h (figure 11). P P P Screen brightness: Individual adjustment of the screen brightness for operation. The display is not switched off completely with at value 0%, residual bright- ness is always still present. Screensaver: Basic setting for the screensaver (brightness, screensaver symbol). Language: Changeover of the display and menu language to German, English, French,... Programming mode: Activation of the programming mode. The device can be loaded with the physical address and application software. Reset: Resetting to the factory settings. Afterwards, the device must be reprogrammed and set. Info: Display of system information using the touch control surface under , such as the manu- facturer, software version, last ETS download date and phys. address. Timer menu - A4 In the timer menu you have to set on which week- days or sections of the week and at what times the operating modes Comfort, Standby or Economy mode (Night Reduction) should be switched on and off. Timer program Monday-Friday Saturday-Sunday Monday-Sunday Figure 12: Setting timer Setting switching times for operating mode change- over z Select a section of the week or weekday with / . z Confirm with .(figure 12). The display changes for setting the switching time (figure 13). The operating mode Economy (Night Reduction) is selected automatically. If necessary, change with to select another operating mode (figure 14). z Set the switch-on/switch-off time with / (figure 13). 00:00 Timer program Figure 13: Setting the switching time The operation should be repeated for additional switching times. z Swipe your finger over the touch control surface. The display returns to the Timer submenu. The coloured circle next to the weekday or section of the week changes colour. Weekdays or sections of the week with the same coloured circle are configured with the same timers. P Activating/deactivating timer Timer program Timer program Monday Monday-Sunday Activating/deactivating the timer z Select the timer parameter with / . z Switch timer on/off using / . If the timer is activated, the set programming block is automatically executed once a week recurrently. If the timer is deactivated, adjust- ments to the temperature setpoint or operating mode must be set manually. Optimisation: The KNX thermostat/room controller "learns" inde- pendently which lead time is required to reach the desired temperature. Holiday mode menu - A5 In the holiday mode menu the set temperature can lowered to an adjustable minimum temperature in absence. Vacation mode Figure 15: Activating holiday mode z Activate the holiday mode with . The symbol changes to the display . In the status line (6) of the basic display indicates the holiday mode. The display changes for setting the operating mode for the holiday mode (figure 16). Holiday mode Figure 16: Selecting operating mode for holiday mode z Select the desired operating mode for the peri- od of absence. The display additionally indicates the number of days for the holiday mode. 1 Holiday mode Number of days OK Figure 17: Setting duration of holiday mode P P z Increase/decrease the number of days of ab- sence with / . z Confirm the setting with OK The holiday mode operating mode is activated for the duration of the set days. The display switches to the holiday mode display (figure 17). z Deactivate the holiday mode prematurely with the touch area. In the status line (6) of the basic display the symbol for the holiday mode disappears. Or: z Confirm the entry with . Operating mode menu - A6 In the operating mode menu, you can select be- tween three operating modes (figure 19): Mode selection Figure 18: Selecting operating mode - Comfort in presence - Standby in absence - Economy (nighttime operation) for the night re- duction z Activate the desired mode using the touch control surface. In the status line (6) of the basic display the symbol. / / indicates the respective holiday mode. Extractor fan menu- A7 In the extractor fan menu, extractor fan stages from 0 ... 6 can be set. 2 a Fan control Figure19: Setting of the extractor fan stages z Increase/decrease the extractor fan stage with touch control surface / . The number in the extractor fan symbol indi- cates the set stage. z Press touch control surface a. The extractor fan function switches to automatic operation. The symbol a provides the option of returning back to manual operation . s å `

hager WUT09: Controller Category Related Instructions

UT75A
YOKOGAWA UT75A
17.08.2026 498 pages

User’s Manual UT75A Digital Indicating Controller User’s Manual IM 05P01B41-01EN IM 05P01B41-01EN 3rd Edition Functional Enhancement User support guide for the YOKOGAWA UT75A Controller. It explains installation, setup, and device calibration, user settings, product specifications.

York YKN2Open board
Johnson Controls York YKN2Open board
23.05.2026 44 pages

YKN2Open board Technical Information Ref.: N-27730_EN 1113 Manual for safe operation of the Johnson Controls York YKN2Open board Controller. This manual covers installation, operation, and energy usage, device safety checks, installation guides.

Z series
CAME Z series
13.04.2026 18 pages

s F B l E Z l Z s r n r s l srnrr Z Krl zBxT AF ? - 6 3 mm. n , : l l ?nr** 80AFo ZBXT ,uE (€ [EqP4N9!J ) o l |z I l ù : i s : i ì : i o i \ z a , ) | Documenlazione Tecnica s 1 9 rev 2.1 11120f5 Oclue CANCÉLLI AI'TOMATICI 3 1 9 5 1 9 - 1 SCHEDA COM Essential instructions for the CAME Z series Control Unit. The guide provides instructions on specifications, energy usage, safety.

Electronic Brake Control
Tekonsha Electronic Brake Control
29.06.2026 2 pages

Electronic Brake Control For 2, 4, 6* and 8* brake applications Components of the Brake Control A. Power Knob B. Manual Slide Knob C. Bracket Mounting Holes D. Bi-Colored Light E. Level Knob Important Facts to Remember 1. Do not mount or activate RF generating Operating and setup manual for the Tekonsha Electronic Brake Control Controller. It explains maintenance and security instructions, installation steps, installation.