Operation & user’s manual [PDF] (12 pages)
- Updated: 02.04.2026
Document Preview & Text Transcription
1
LZR
®
EN
FOR PLATFORM SCREEN DOORS
detection range of 5.0 m x 5.0 m
LASER SCANNERS
User’s Guide for product version 0600 and more
-T305/LZR-T305-P
2
Avoid extreme
vibrations.
Do not cover
the front screens.
Avoid moving objects
and light sources in
the detection field.
Avoid condensation.
Avoid the presence
of smoke and fog in
the detection field.
Avoid exposure to
sudden and extreme
temperature changes.
Keep the sensor
permanently powered
in environments where
the temperature can
descend below -10°C.
Wipe the front
screens regularly
with a clean and
damp cloth.
Do not use aggressive
products to clean
the front screens.
Avoid direct exposure
to high pressure
cleaning.
SAFETY
INSTALLATION AND MAINTENANCE
Do not look into the laser
emitter or the visible red
laser beams.
The warranty is void if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Only trained and qualified
personnel may install and
adjust the sensor.
The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the
door system in compliance with applicable national and international regulations and standards on door safety and if
applicable, the machinery directive 2006/42/EC. Other use of the device is outside the permitted purpose and can not be
guaranteed by the manufacturer. The manufacturer cannot be held responsible for incorrect installations or inappropriate
adjustments of the sensor.
Test the good functioning
of the installation before
leaving the premises.
The device contains IR and visible laser diodes.
IR laser: wavelength 905nm; max. output pulse power 75W
(Class 1 according to IEC 60825-1)
Visible laser: wavelength 650nm; max. output CW power 3mW
(Class 3R according to IEC 60825-1)
The visible laser beams are inactive during normal functioning.
The installer can activate the visible lasers if needed.
CAUTION!
Use of controls, adjustments or performance of procedures other than those specified herein
may result in hazardous radiation exposure.
3
1
2
3
4
5
6
8
10
9
7
1
2
3
4
1x
DESCRIPTION
SYMBOLS
LED-SIGNAL
DETECTION LEDs
no detection
ERROR LED
POWER LED
detection
no error
error
no power
power
Caution!
Laser radiation
LED flashes quickly
LED flashes
LED is off
1.
laser sweep emission
2.
laser sweep reception
3.
LED-signals (4)
4.
screws for position lock (2)
5.
connector
6.
protection cover
7.
visible laser beams (3)
8.
notches for tilt angle adjustment (2)
9.
adjustable bracket
10.
cable conduits (4)
1. Detection LED: relay 1 - optional field
2. Detection LED: relay 2 - safety field
3. Error LED
4. Power LED
Remote control
sequence
Possible
remote control
adjustments
Factory
values
LED flashes slowly
All 4 LEDs can be switched off and on again by remote control.
This can be useful in cases where the sensor should not draw any attention.
LED flashes once
Attention!
Important!
Tip
Info
CAT2
Pl d
CAT2
Pl d
EN ISO 13849-1:2008
CAT 2, Pl «d»
According
to
Not
according
to
4
x
4x
2x
1x
3x
30’
HOW TO USE THE REMOTE CONTROL
30 minutes after last use, the sensor locks the access to the remote control session.
Cut and restore power supply. The remote control session is accessible again during 30 minutes.
ADJUSTING ONE OR MORE PARAMETERS
CHECKING A VALUE
RESTORING TO FACTORY VALUES
SAVING AN ACCESS CODE
DELETING AN ACCESS CODE
The access code is recommended for sensors installed close to each other.
After unlocking, the red
LED flashes and the sensor
can be adjusted by remote
control.
If the red LED flashes quickly after unlocking, you
need to enter an access code from 1 to 4 digits.
= field width: 4.2 m
= field width is defined by teach-in
To end an adjustment session,
always lock the sensor.
Enter the existing code
teach-in
X = number of flashes = value of the parameter
Pages Preview: