Halma BEA LZR-T305 Manuals

1 pdf manual(s) Halma BEA LZR-T305 for free download (Document Types: Operation & user’s manual)

Document Preview & Text Transcription

1 LZR ® EN FOR PLATFORM SCREEN DOORS detection range of 5.0 m x 5.0 m LASER SCANNERS User’s Guide for product version 0600 and more -T305/LZR-T305-P 2 Avoid extreme vibrations. Do not cover the front screens. Avoid moving objects and light sources in the detection field. Avoid condensation. Avoid the presence of smoke and fog in the detection field. Avoid exposure to sudden and extreme temperature changes. Keep the sensor permanently powered in environments where the temperature can descend below -10°C. Wipe the front screens regularly with a clean and damp cloth. Do not use aggressive products to clean the front screens. Avoid direct exposure to high pressure cleaning. SAFETY INSTALLATION AND MAINTENANCE Do not look into the laser emitter or the visible red laser beams. The warranty is void if unauthorized repairs are made or attempted by unauthorized personnel. Only trained and qualified personnel may install and adjust the sensor. The manufacturer of the door system is responsible for carrying out a risk assessment and installing the sensor and the door system in compliance with applicable national and international regulations and standards on door safety and if applicable, the machinery directive 2006/42/EC. Other use of the device is outside the permitted purpose and can not be guaranteed by the manufacturer. The manufacturer cannot be held responsible for incorrect installations or inappropriate adjustments of the sensor. Test the good functioning of the installation before leaving the premises. The device contains IR and visible laser diodes. IR laser: wavelength 905nm; max. output pulse power 75W (Class 1 according to IEC 60825-1) Visible laser: wavelength 650nm; max. output CW power 3mW (Class 3R according to IEC 60825-1) The visible laser beams are inactive during normal functioning. The installer can activate the visible lasers if needed. CAUTION! Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. 3 1 2 3 4 5 6 8 10 9 7 1 2 3 4 1x DESCRIPTION SYMBOLS LED-SIGNAL DETECTION LEDs no detection ERROR LED POWER LED detection no error error no power power Caution! Laser radiation LED flashes quickly LED flashes LED is off 1. laser sweep emission 2. laser sweep reception 3. LED-signals (4) 4. screws for position lock (2) 5. connector 6. protection cover 7. visible laser beams (3) 8. notches for tilt angle adjustment (2) 9. adjustable bracket 10. cable conduits (4) 1. Detection LED: relay 1 - optional field 2. Detection LED: relay 2 - safety field 3. Error LED 4. Power LED Remote control sequence Possible remote control adjustments Factory values LED flashes slowly All 4 LEDs can be switched off and on again by remote control. This can be useful in cases where the sensor should not draw any attention. LED flashes once Attention! Important! Tip Info CAT2 Pl d CAT2 Pl d EN ISO 13849-1:2008 CAT 2, Pl «d» According to Not according to 4 x 4x 2x 1x 3x 30’ HOW TO USE THE REMOTE CONTROL 30 minutes after last use, the sensor locks the access to the remote control session. Cut and restore power supply. The remote control session is accessible again during 30 minutes. ADJUSTING ONE OR MORE PARAMETERS CHECKING A VALUE RESTORING TO FACTORY VALUES SAVING AN ACCESS CODE DELETING AN ACCESS CODE The access code is recommended for sensors installed close to each other. After unlocking, the red LED flashes and the sensor can be adjusted by remote control. If the red LED flashes quickly after unlocking, you need to enter an access code from 1 to 4 digits. = field width: 4.2 m = field width is defined by teach-in To end an adjustment session, always lock the sensor. Enter the existing code teach-in X = number of flashes = value of the parameter