Hamilton ATI 2H Manuals

1 pdf manual(s) Hamilton ATI 2H for free download (Document Types: Quick start manual)

Hamilton ATI 2H Quick start manual Thumbnail

Hamilton ATI 2H Quick start manual [PDF] (2 pages)

  • Identifier: id-2042019
  • Brand: Hamilton
  • Device: Hamilton ATI 2H Laboratory Equipment
  • Type: Quick start manual, PDF
  • Key Aspects: Unpacking and Inspection Guidelines, Model Variations and Compatibility, Product Performance Metrics
  • UPD Date: 29.04.2026
  • Source File: 2245839.pdf
  • Pages: 2
  • Description: Advanced user manual for the Hamilton ATI 2H.
Pages Preview:
  • Hamilton ATI 2H Quick start manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
AIR TECHNIQUES INTERNATIONAL A Division of Hamilton Associates, Inc. 11403 Cronridge Drive  Owings Mills, MD 21117-2247 USA Tel 410.363.9696  Fax 410.363.9695 http://www.atitest.com 2H AMPLIFIER LINEARITY CHECK U S I N G A P I C O A M P E R E S O U R C E Page 1 of 2 PCL-103-WI Rev B 19-July-2011 Use only the equipment specified: Keithley 6220 picoampere current source NOTE: The following procedure is intended for ATI-2H units that have previously had Internal Reference values stored in battery-backed RAM. Procedure: 1. Be sure that both the picoampere source and the 2H unit are powered down. 2. Switch on the picoampere source. Ensure the blue output LED indicates an OFF (disabled) state. 3. Switch on the power to the 2H unit. The unit will briefly sound an audible tone, display the software version and start scanning. 4. The LED on the “REF” button should start blinking. 5. Press the “ENTER” button and the stored Reference reagent value (DOP, PAO, User or High) will be displayed on the %Leakage display. Use the or key to change the selection to PAO. 6. Press the “ENTER” button again and “100” will be displayed on the %Leakage display. 7. Press the “ENTER” button again. After scanning the LED over the “0” key should begin flashing. 8. Press “ENTER” button again. The 2H unit will scan for approximately 10 seconds and display all zeros on the %Leakage display. 9. Disconnect phototube signal from signal connector labeled J2 on the 2H unit main PCBA and connect the output of the picoampere source to J2. 10. Set the picoampere source to -08.000 µA (-0.80 X 10-5 amperes) and enable the signal output. 11. Press the “100” key and the “ENTER” button sequentially. The unit will begin scanning. When complete, the LED over the “0” key will begin flashing. 12. Disable the picoampere source signal output. 13. Press “ENTER” button on the 2H. The 2H unit will start scanning. When complete, the 2H % Leakage display should show “0.0000” and an audible tone will sound. 14. Enable the picoampere source signal output. 15. The 2H % Leakage display should show “100.00”. (Tolerance: -0.80 ± .02 x 10-5 amperes). Record the picoampere source reading on the calibration report of the UUT. NOTE: Leave the picoampere source output enabled for the following steps until instructed otherwise.

Similar Manuals in the Laboratory Equipment Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Yamato NeoCool Circulator CF301

User Guide: Yamato NeoCool Circulator CF301 (KD428I, Upd.04-08-2026)

31 304 76 04-08-2026 view all manuals
Chopin RHEO F4

#RR9EZ2: RHEO F4 Laboratory Equipment Quick installation and first test

16 1365 260 06-07-2026 view all manuals
BioQuip CDC Mini

Guide: BioQuip CDC Mini (18QPMY, Upd.10-08-2026)

2 1386 222 10-08-2026 view all manuals
Alliance Bio Expertise MEDIAWEL 10

Guide: Alliance Bio Expertise MEDIAWEL 10 (528X96, Upd.17-06-2026)

85 212 41 17-06-2026 view all manuals
HMC HG-50

HG-50 (Laboratory Equipment ePDF User Manual, #4OQX21)

38 894 170 27-07-2026 view all manuals
PI L-738 Series

PDF Guide (@TLHQDZ), PI L-738 Series Laboratory Equipment (02-08-2026)

55 1434 330 02-08-2026 view all manuals