Hanna Instruments Checktemp Dip HI98539 Manuals

1 pdf manual(s) Hanna Instruments Checktemp Dip HI98539 for free download (Document Types: Instruction manual)

Document Preview & Text Transcription

HI98539 Digital Thermometer INSTRUCTION MANUAL Checktemp®Dip All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA. IST98539 11/15 Warranty Checktemp®Dip is guaranteed for a period of one year after date of purchase against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna Office. If under warranty, report the model number, date of purchase, serial number and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Technical Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packed for complete protection. Recommendations for Users Before using Hanna Products, make sure that they are entirely suitable for your specific application and for the environment in which they are used. Operation of these instruments may cause unacceptable interferences to other electronic equipment, thus requiring the operator to take all necessary steps to correct such interferences. Batteries should only be replaced in a safe area using the battery type specified in this instruction manual. Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC performance. To avoid damages or burns, do not put the instrument in microwave oven. For yours and the instrument safety do not use or store the instrument in hazardous environments. Liquid Crystal Display Silicone Probe Cable ON/OFF Button SET Button Battery Cover REAR °C °F Range -20.0 to 80.0°C -4.0 to 176.0°F Resolution 0.1°C 0.1°F Accuracy ±0.3°C ±0.5°F Probe weighted stainless steel probe with 3 m (9.9’) silicone cable Battery Type / Life 3 x 1.5V AAA alkaline / approximately 2 years of use Auto Off 8 min (default), 60 min or OFF Environment -30 to 50°C (-22 to 122°F); IP65 Dimensions 107 x 59 x 17 mm (4.2 x 2.3 x 0.7’’) Weight 109 g (3.8 oz.) Operation Turn Checktemp®Dip ON: all LCD segments are displayed for 1 second. CAL Check® starts automatically to verify that Checktemp®Dip is still accurate to its specifications. A message of “CAL“ and “-0-“ means that Checktemp®Dip is within specifications. You can now start using Checktemp®Dip. If CAL Check® displays the “Err” message while measuring temperature, remember that: · The temperature sensor is located at the tip of the stainless steel probe. · It is necessary to wait for a few seconds for the display to stabilize. Specifications Meter Setup Enter Setup to change between Temperature Unit and to adjust the Auto Shut-off time. To enter the Setup MODE, press the SET button located inside the battery compartment once for Temperature Unit or twice for Auto Shut-off. To enter the Setup mode, remove battery cover and press SET button. The display will show the current temperature unit (E.g. “°C“). Then: · Use the ON/OFF button to switch between “ºC” or “ºF”. Press SET once to save. · Use the ON/OFF button to cycle through the following Auto Shut-off options: 8 minutes (“d08”, default value), 60 minutes (“d60”), OFF (“d--”). Press the SET button once to save. Battery Replacement Replace the battery when the battery symbol is blinking or when Checktemp®Dip does not turn on. Open the compartment and replace the three AAA batteries, while paying attention to their polarity. Close battery cover. Note: Batteries should only be replaced in a safe area using the battery type specified in this instruction manual. Old batteries should be disposed in accordance with local regulations. Weighted Temperature Probe Thank You Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using the instrument. For more information about Hanna and our products, visit www.hannainst.com. For technical support, contact your local Hanna office or email us at [email protected] Find your local Hanna office on www.hannainst.com