Hanna Instruments Checktemp HI 98501 Manuals

1 pdf manual(s) Hanna Instruments Checktemp HI 98501 for free download (Document Types: Instruction manual)

Available Documents for Checktemp HI 98501:

Hanna Instruments Checktemp HI 98501 Instruction manual Main Page Preview

Instruction manual [PDF] (2 pages)

  • Brand: Hanna Instruments
  • Model: Checktemp HI 98501
  • Format: PDF
  • Key Aspects: Routine Functionality Testing, Device Specifications Overview, Basic Configuration Guidelines
  • Updated: 22.07.2026
  • Source File: 1743064.pdf
  • Pages: 2
  • Description: Owner’s guide for the Hanna Instruments Checktemp HI 98501.

Document Preview & Text Transcription

Hanna Instruments Inc. 584 Park East Drive Woonsocket, RI 02895 www.hannainst.com www.hannainst.com HI 98501 (Checktemp®) Instruction Manual [email protected] www.ponpe.com Thank You! Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using the instrument. For additional information, visit www.hannainst.com or e-mail us at [email protected]. Specifcations Operation Turn Checktemp® ON with ON/OFF button: all LCD segments are displayed for 1 second, and CalCheck® starts automatically to verify that Checktemp® of “CAL“ and “-0-“ means that Checktemp® is measuring temperature, remember that: · The temperature sensor is located at the tip of the stainless steel probe. · It is necessary to wait for a few seconds for the display to stabilize. Liquid Crystal Display ON/OFF button Maximum Immersion Level Temperature Probe 4 cm 1.5” Battery Setup Button Recommended Immersion Level Range -50.0 to 150.0 ºC / -58.0 to 302 ºF Resolution 0.1 ºC (-50.0 to 150.0 ºC) 0.1 ºF (-58.0 to 199.9 ºF) / 1 ºF (above 200 ºF) Accuracy ±0.2 ºC (-30.0 to 120.0 ºC) ±0.3 ºC (outside: -50.0 to -30.0 ºC and 120.0 to 150.0 ºC) ±0.5 ºF (-22.0 to 199.9 ºF) ±1 ºF (outside: -58.0 to -22.0 ºF and 200 to 302 ºF) Environment -30 to 50 ºC (-22 to 122 ºF) Battery Type 1 x CR2032 Battery Life approx. 2000 hours of continuous use Auto Of 8 min (default), 60 min or OFF Dimensions 50 x 185 x 21 mm (2 x 7.3 x 0.9“) Weight 50 g (1.8 oz.) All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc., Woonsocket, Rhode Island, 02895, USA. IST98501 09/14 Warranty Checktemp® is guaranteed for a period of one year after date of purchase against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. This warranty is limited to repair or replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna Ofce. If under warranty, report the model number, date of purchase, serial number and the nature of the problem. If the repair is not covered by the warranty, you will be notifed of the charges incurred. If the instrument is to be returned to Hanna Instruments, frst obtain a Returned Goods Authorization number from the Technical Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packed for complete protection. Recommendations for Users Before using Hanna Products, make sure that they are entirely suitable for your specifc application and for the environment in which they are used. Operation of these instruments may cause unacceptable interferences to other electronic equipment, thus requiring the operator to take all necessary steps to correct such interferences. Batteries should only be replaced in a safe area using the battery type specifed in this instruction manual. Any variation introduced by the user to the supplied equipment may degrade the instrument’s EMC performance. To avoid damages or burns, do not put the instrument in microwave oven. For yours and the instrument safety do not use or store the instrument in hazardous environments. Meter Setup Enter Setup to change the temperature unit (ºC or Setup MODE, press the SET button located inside the battery compartment once for temperature · Use the ON/OFF button to switch between “ºC” or “ºF”. Press SET once to save and continue to auto shut of settings. · Use the ON/OFF button to cycle through the following Auto Shut Of options: 8 minutes (“d08”, default value), 60 minutes (“d60”), OFF (“d--”). Press the SET button once to save and continue to normal operation. Battery Replacement Replace the battery when the battery symbol is blinking or when Checktemp® does not switch on. If the meter has been submerged in a liquid, make sure it has been completely dried. Check the polarity of the battery, open the compartment, and replace the battery. Close battery cover. Note: Batteries should only be replaced in a safe area using the battery type specifed in this instruction manual. Old batteries should be disposed in accordance with local regulations. Troubleshooting Errors that may occur: A message of “CAL” and “Err” means an internal error has occurred and Checktemp® is not guaranteed to be within its and the display shows “---” the temperature connection to the probe has been broken. If a message of “Err” occurs then a calibration data read error has occurred. A message of “Er1” is caused by an unexpected device reset. A message of “Er2” occurs if internally a temperature measurement malfunctions. After these messages Checktemp® OFF and then ON with the ON/OFF button to reset. If the error message continues to Certifcation EN 13485:2001 - Suitability: Storage; Environment: E; Accuracy Class: 0.5; IP65 EN 13485 Storage E / 0.5 www.ponpe.com [email protected]