Hanna Instruments HI 93551 Manuals

3 pdf manual(s) Hanna Instruments HI 93551 for free download (Document Types: Instruction manual)

Document Preview & Text Transcription

Instruction Manual HI 93530 - HI 93531 HI 93532 - HI 93551 HI 935005 - HI 935006 HI 935007 Microprocessor-based Thermocouple Thermometers ins rum ns °C °F MEM- HOLD HI MR K-THERMOCOUPLE THERMOMETER HI 93531 LO OFF ON °C h t t p : / / w w w . h a n n a c a n . c o m These Instruments are in Compliance with the CE Directives MANK93R3 04/98 h t t p : / / w w w . h a n n a c a n . c o m PRINTED IN ITALY 2 Dear Customer, Thank you for choosing a Hanna Instruments Product. Please read this instruction manual carefully before using the instrument. This manual will provide you with all the necessary information for the correct use of the instrument, as well as a precise idea of its versatility in a wide range of applications. These instruments are in compliance with the directives EN 50081-1 and EN 50082-1. TABLE OF CONTENTS TABLE OF CONTENTS Preliminary Examination ............................ 3 General Description.................................... 3 Functional Description and Specifications of HI 93530 .......................... 5 Functional Description and Specifications of HI 93531 .......................... 6 Functional Description and Specifications for HI 93532 ......................... 7 Functional Description and Specifications of HI 93551 ........................ 8 Functional Description and Specifications of HI 935005 ...................... 9 Functional Description and Specifications of HI 935006 .................... 10 Functional Description and Specifications of HI 935007 .................... 11 Operational Guide ................................... 12 Display Codes Guide............................... 19 Battery Replacement............................... 20 Calibration ............................................... 20 Shockproof Rubber Boots ....................... 21 Accessories ............................................. 22 Warranty.................................................. 26 CE Declaration of Conformity ................. 27 CE DECLARATION OF CONFORMITY Recommendations for Users Before using these products, make sure that they are entirely suitable for the environment in which they are used. Operation of these instruments in residential area could cause unacceptable interferences to radio and TV equipments, requiring the operator to take all necessary steps to correct interferences. Any variation introduced by the user to the supplied equipment may degrade the instruments' EMC performance. In particular cases the instruments could turn off. In such cases they can be turned on by pressing the ON/OFF key. To avoid electrical shock, do not use these instruments when voltages at the measurement surface exceed 24VAC or 60 VDC. To avoid damages or burns, do not perform any measurement in microwave ovens. 3 PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipment. If noticeable damage is evident, notify your Dealer. Each thermometer comes supplied with a 9V battery and instruction manual. Note: Save all packing material until you are sure that the instrument functions correctly. All defective items must be returned in the original packing to- gether with the supplied accessories. GENERAL DESCRIPTION HI93530, HI93531, HI93532, HI935005 and HI935007 allow temperature measurement using interchangeable K-type thermocouple probes. HI 93551 allows temperature measurements with different types of thermocouples (K- J - T). This meter is equipped with a key that switches range from K-type to J-type or T-type thermocouples. HI935006 and HI935007 are specifically de- signed for the food industry. HI935006 al- lows temperature measurement using inter- changeable T-type thermocouple probes. HI935007 uses a fixed K-type penetration temperature probe (HI 766C) with 1 m (3.3') cable. The non-linearity of the temperature probe is linearized by the built-in microprocessor, in order to achieve high degree accuracy and resolution. It also permits accurate com- pensation for drifts in the measurement cir- cuit and the reference junction. All Hanna Instruments meters are warranted for two years against defects in workman- ship and materials when used for their in- tended purpose and maintained according to instructions. The probes are warranted for a period of six months. This warranty is limited to repair or replace- ment free of charge. Damages due to accident, misuse, tamper- ing or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instrument. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization Num- ber from the Customer Service department and then send it with shipment costs pre- paid. When shipping any instrument, make sure it is properly packaged for complete protection. To validate your warranty, fill out and return the enclosed warranty card within 14 days from the date of purchase. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner. WARRANTY Hanna Instruments reserves the right to modify the design, construction and ap- pearance of its products without advance notice.

Document Preview & Text Transcription

Instruction Manual HI93551 • HI93551N HI93551R HI93542 • HI93552 HI93552R K J T - Thermometers www.hannainst.com 2 TABLE OF CONTENTS Preliminary Examination...............................................................3 General Description.......................................................................3 Specifications of HI93551 and HI93551N .....................................4 Specifications of HI93542 and HI93552 .......................................6 Specifications of HI93551R and HI93552R................................... 8 Operational Guide ..................................................................... 10 Serial Port Communication ......................................................... 15 User Calibration ......................................................................... 16 Factory Recalibration .................................................................. 16 Battery Replacement .................................................................. 17 Accessories .................................................................................. 18 Dear Customer, Thank you for choosing a Hanna Instruments product. Please read this instruction manual carefully before using this instrument. For more information about Hanna Instruments and our products, visit www.hannainst.com or e-mail us at [email protected]. For technical support, contact your local Hanna Instruments Office or e-mail us at [email protected]. WARRANTY HI93551, HI93551N, HI93542, HI93552, HI93551R ans HI93552R are guaranteed for two years against defects in workmanship and materials when used for their intended purpose and maintained according to instructions. Electrodes and probes are guaranteed for six months. This warranty is limited to repair or replacement free of charge. Damage due to accidents, misuse, tampering or lack of prescribed maintenance is not covered. If service is required, contact your local Hanna Instruments Office. If under warranty, report the model number, date of purchase, serial number and the nature of the problem. If the repair is not covered by the warranty, you will be notified of the charges incurred. If the instrument is to be returned to Hanna Instruments, first obtain a Returned Goods Authorization number from the Technical Service department and then send it with shipping costs prepaid. When shipping any instrument, make sure it is properly packed for complete protection. 3 PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it carefully to make sure that no damage has occurred during shipping. If there is any damage, please contact your local Hanna Instruments Office.PC Each instrument is supplied with: • 3 x 1.5V AA alkaline batteries • Instruction manual. Note: Save all packing material until you are sure that the instrument functions correctly. All defective items must be returned in the original packing with the supplied accessories. GENERAL DESCRIPTION These instruments are powerful and flexible thermometers, which can take measurements using different types of thermocouple probes (K, J and T), and have been designed using the latest microprocessor technology to provide reliable and accurate high resolution measure- ments in a wide temperature reange. Standard features include dual-level LCD (which allows continuous displaying of High and Low temperature values), °C/°F selection, HOLD function, auto-off capability, remaining battery life indication, low battery detection, long battery life and two-year warranty. HI93542, HI93552 and HI93552R are two-channel thermometers, ideal for monitoring two samples at once. HI93551N, HI93551R, HI93552 and HI93552R offer additional features, such as calibration of meter and probe at 0°C, backlit display, and capability to store and recall a reading. Moreover, the HI93551R and HI93552R models are equipped with a serial port interface. All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. Hanna Instruments reserves the right to modify the design, construction or appearance of its products without advance notice.

Document Preview & Text Transcription

Instruction Manual HI 93551 • HI 93551N HI 93551R HI 93542 • HI 93552 HI 93552R K J T - Thermometers w w w . h a n n a i n s t . c o m 3 2 PRELIMINARY EXAMINATION Remove the instrument from the packing material and examine it to make sure that no damage has occurred during shipping. If there is any damage, notify your dealer or the nearest Hanna Customer Service Center. Each meter is supplied complete with: • 3 x 1.5V AA alkaline batteries • Instruction manual. Note: Save all packing material until you are sure that the instrument functions correctly. All defective items must be returned in the original packing with the supplied accessories. Dear Customer, Thank you for choosing a Hanna product. Please read this instruction manual carefully before using the instru- ment. If you need additional technical information, do not hesitate to e-mail us at [email protected]. These instruments are in compliance with the directives. GENERAL DESCRIPTION These instruments are powerful and flexible thermometers, which can take measurements using different types of thermocouple probes (K, J and T), and have been designed using the latest microprocessor technology to provide reliable and accurate high resolution measure- ments in a wide temperature reange. Standard features include dual-level LCD (which allows continuous displaying of High and Low temperature values), °C/°F selection, HOLD function, auto-off capability, remaining battery life indication, low battery detection, long battery life and two-year warranty. HI 93542, HI 93552 and HI 93552R are two-channel thermometers, ideal for monitoring two samples at once. HI 93551N, HI 93551R, HI 93552 and HI 93552R offer additional features, such as calibration of meter and probe at 0°C, backlit display, and capability to store and recall a reading. Moreover, the HI 93551R and HI 93552R models are equipped with a serial port interface. WARRANTY All Hanna Instruments meters are warranted for two years against defects in workmanship and materials when used for their intended purpose and main- tained according to instructions. The probes are warranted for a period of six months. This warranty is limited to repair or replacement free of charge. Damages due to accidents, misuse, tampering or lack of prescribed maintenance are not covered. If service is required, contact the dealer from whom you purchased the instru- ment. If under warranty, report the model number, date of purchase, serial number and the nature of the failure. First obtain a Returned Goods Authoriza- tion number from the Customer Service department, then return the instrument with the Authorization number included along with shipment costs prepaid. If the repair is not covered by the warranty, you will be notified of the charges. When shipping any instrument, make sure it is properly packaged for complete protec- tion. TABLE OF CONTENTS Preliminary Examination...............................................................3 General Description.......................................................................3 Specifications of HI 93551 and HI 93551N .................................. 4 Specifications of HI 93542 and HI 93552 .................................... 6 Specifications of HI 93551R and HI 93552R ................................ 8 Operational Guide ..................................................................... 10 Serial Port Communication ......................................................... 15 User Calibration ......................................................................... 16 Factory Recalibration .................................................................. 16 Battery Replacement .................................................................. 17 Accessories .................................................................................. 18 All rights are reserved. Reproduction in whole or in part is prohibited without the written consent of the copyright owner, Hanna Instruments Inc. Hanna Instruments reserves the right to modify the design, construction and appearance of its products without advance notice. 5 4 HI 93551 HI 93551N SPECIFICATIONS OF HI 93551 & HI 93551N SPECIFICATIONS Range (*) K -200.0 to 999.9°C / 1000 to 1371°C -328.0 to 999.9°F / 1000 to 2500°F J -200.0 to 999.9°C -328.0 to 999.9°F / 1000 to 1832°F T -200.0 to 400.0°C -328.0 to 752.0°F Resolution K 0.1°C (-149.9 to 999.9°C) 0.2°C (-200.0 to -150.0°C) / 1°C (1000 to 1371°C) 0.1°F (-24.9 to 999.9°F) / 0.2°F (-249.9 to -25.0°F) 0.3°F (-328.0 to -250.0°F) / 1°F (1000 to 2500°F) J 0.1°C (-200.0 to 999.9°C) 0.1°F (-149.9 to 999.9°F) 0.2°F (-328.0 to -150.0°F) / 1°F (1000 to 1832°F) T 0.1°C (-149.9 to 400.0°C) 0.2°C (-200.0 to -150.0°C) 0.1°F (0.0 to 752.0°F) / 0.2°F (-270.0 to -0.1°F) 0.3°F (-328.0 to -270.1°F) Accuracy ±0.5°C (-100.0 to 999.9°C) / ±1°C (outside) (@20°C/68°F) ±1°F (-148.0 to 999.9°F) / ±1.5°F (outside) for one year, excluding probe error Typical EMC Deviation ± 3°C / ± 6°F Battery 3x1.5V AA (IEC LR6) batteries, approx. 500 hours of continuous use Auto-off user selectable: 60 min or disabled Environment -10 to 60°C (14 to 140°F); RH 100% Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4") Weight 235 g (8.3 oz.) Keyboard Functions: ON/OFF : turn the meter ON and OFF. HOLD : freeze the reading on display. °C/°F : change reading unit (°C or °F). KJT : select the thermocouple type. CLR : clear the HI and LO values. CAL (HI 93551N only) : press and hold for about 5 seconds to enter the Calibration mode (with reading within ±3°C range); press to abort the Calibration mode. (*) Range may be limited by probe. 7 6 HI 93542 HI 93552 SPECIFICATIONS OF HI 93542 & HI 93552 Keyboard Functions: ON/OFF : turn the meter ON and OFF. T1/T2 : select the reading channel (T1, T2 or T1-T2). HOLD : freeze the reading on display. In HI 93552, the frozen value is also stored in non-volatile memory. CLR : clear the HI and LO values, reset the relative or average measurement. DISP : select Normal, Relative, Average or T1/T2 measuring mode. KJT : select the thermocouple type. ALT (HI 93552 only) : enable the second function keys; the "ALT" tag turns on to indicate that the second functions are enabled. Note: The ALT key can be released before pressing the second function key for 1-hand operation. ALT/u CAL : press and hold for about 5 seconds to enter the Calibration mode (with reading within ±3°C range). (ALT +) AOFF : set auto-off delay (8min, 60min, disabled). (ALT +) °C/°F : change reading units (°C or °F). (ALT +) MR : recall memorized value. (ALT +) KJT : select the thermocouple type. (ALT +) BL : toggle the backlight ON and OFF. SPECIFICATIONS Range (*) K -200.0 to 999.9°C / 1000 to 1371°C -328.0 to 999.9°F / 1000 to 2500°F J -200.0 to 999.9°C -328.0 to 999.9°F / 1000 to 1832°F T -200.0 to 400.0°C -328.0 to 752.0°F Resolution K 0.1°C (-149.9 to 999.9°C) 0.2°C (-200.0 to -150.0°C) / 1°C (1000 to 1371°C) 0.1°F (-24.9 to 999.9°F) / 0.2°F (-249.9 to -25.0°F) 0.3°F (-328.0 to -250.0°F) / 1°F (1000 to 2500°F) J 0.1°C (-200.0 to 999.9°C) 0.1°F (-149.9 to 999.9°F) 0.2°F (-328.0 to -150.0°F) / 1°F (1000 to 1832°F) T 0.1°C (-149.9 to 400.0°C) 0.2°C (-200.0 to -150.0°C) 0.1°F (0.0 to 752.0°F) / 0.2°F (-270.0 to -0.1°F) 0.3°F (-328.0 to -270.1°F) Accuracy ±0.5°C (-100.0 to 999.9°C) / ±1°C (outside) (@20°C/68°F) ±1°F (-148.0 to 999.9°F) / ±1.5°F (outside) for one year, excluding probe error Typical EMC Deviation ± 3°C / ± 6°F Battery 3x1.5V AA (IEC LR6) batteries, approx. 500 hours of continuous use (BL off) Auto-off user selectable: 60 min or disabled (HI 93542) user selectable: 8 min, 60 min, disabled (HI 93552) Environment -10 to 60°C (14 to 140°F); RH 100% Dimensions 150 x 80 x 36 mm (5.9 x 3.1 x 1.4") Weight 235 g (8.3 oz.) (*) Range may be limited by probe.